• 제목/요약/키워드: Commercial pipe

검색결과 193건 처리시간 0.026초

버프의 최적 위치를 통한 산업용 송풍기의 소음저감 (The Noise Reduction of Industrial Blower by Optimal Positioning of Buff)

  • 김창호;손인수;안태수
    • 한국기계가공학회지
    • /
    • 제8권1호
    • /
    • pp.71-76
    • /
    • 2009
  • In a running blower, there are various exciting forces which can generate noise. The noise of an running industrial fan or blower depends on the structure of a fan, the machining accuracy of each element, and assembled conditions. Many studies have been carried out to reduce the noise of it. In this study, 3-hole buffs are used in pipe of blower to study the influence the number and position of buffs on the noise reduction at inlet and outlet in pipe. Commercial engineering software ANSYS and SYSNOISE were employed to analyze the characteristics and reduction ratio of pressure. It is concluded that optimal position and number of buffs in pipe of blower to show the least reduction ratio of pressure.

  • PDF

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

열유속이 있는 난류 원관 유동에의 FLUENT의 2방정식 난류모델의 적용성 판단 (Assessment of two-equation turbulent models in FLUENT for a turbulent heated pipe flow)

  • 문치명;백성구;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.158-163
    • /
    • 2003
  • This paper assesses the two-equation turbulence models available in a commercial code, FLUENT, for heat transfer in a turbulent heated pipe flow. In case of flow under $Re_D=10,000$, Standard $\kappa-\epsilon$ and Realizable $\kappa-\epsilon$ models overpredict the Nusselt number about $20\%$ compared with the experimental correlation, and RNG $\kappa-\epsilon$ model overpredicts about $30\%$ when the two-layer zonal method is employed. When wall function method is adopted, all $\kappa-\epsilon$ models show better predictions. Standard $\kappa-\omega$ and SST $\kappa-\omega$ models have the dependency on the first grid point ($0.3). As Reynolds number becomes high, the predictions of all $\kappa-\epsilon$ and $\kappa-\omega$ models are in a good agreement with the experimental correlation.

  • PDF

초기 인장력을 고려한 파이프계의 자유진동 시뮬레이션 (A Simulation for the Free Vibration of Pipe Systems Considering Initial Tension)

  • 최명진
    • 한국시뮬레이션학회논문지
    • /
    • 제7권2호
    • /
    • pp.105-114
    • /
    • 1998
  • Using finite elements, a simulation is prformed for the pipe systems to investigate free vibrational characteristics, that is natural frequencies, considering the intial tension due to the velocity and the pressure of the inside fluid flow. To confirm the program developed in this study, the results are compared with the results of commercial software ANSYS. When the initial tension is neglected in curved pipes, the natural frequencies are reduced as flow velocity increases, and the rapid decreases of the natural frequencies took place. However, when the initial tension is taken into account, the natural frequencies are not changed with the change of the flow velocity. In free vibrational simulation of pipe systems, it is necessary to calculate the initial state force due to the velocity and the pressure of the fluid flow from the equilibrium first, then the force should be included in the equation of motion of the systems to get more accurate natural frequencies.

  • PDF

GSHP 시스템의 국내적용성에 관한 연구(I) (A Study on the GSHP System for Domestic application(I))

  • 백성권;안형준;박영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.439-444
    • /
    • 2002
  • Geothermal or ground source heat pumps(GSHPs) are electrically powered systems that take advantage of the earth's relatively constant temperature to provide heating, cooling, and hot water for homes and commercial buildings. The buried pipe, or ground loop, is the most recent technical advance in heat pump technology. The idea to bury pipe in the ground to gather heat energy began in the 1940s. Only recently, however, have new heat pump designs and improved buried pipe materials been combined to make GHP systems the most efficient heating and cooling systems available. The aim of the study is application of the GSHP system in korea. Our environments for economy, politics and society are different from other countries. For a case, the progressive tax rate of home electricity is represented.

  • PDF

An Experimental Study on Resisting Force of Scaffolding Frames using Buckled Pipe

  • Na, Young-Chan;Son, Ki-Sang
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.24-28
    • /
    • 2006
  • There are many structural problems when the scaffolding frame is applied to a construction site contractor may use a used pipe or buckled pipe which they lended them from commercial firms without any inspection of those materials even though they have been used and exposed to weather for a long times. Therefore, they should be checked of their current capacity, comparing with the original one so that construction contractor can apply their capacity to a temporary frame depending on the site situation against collapsion of those. This study is mainly focused on the behavior of a scaffolding frame using prebuckled pipes. Additionally, standard frame with bracing and without bracing case are also tested for comparing with the prebuckled case. Prebuckled case has its capacity less approximately 20 % than the standard frame.

내압 및 온도조건을 고려한 Elbow부가 있는 원형배관의 진동해석 (Vibration Analysis of Pipe with Elbow subject to Internal Pressure and Temperature)

  • 김월태;이현승;이영신;조택동;신성기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.223-226
    • /
    • 2004
  • Vibration analysis of pipe with Elbow subject to internal pressure and temperature is studied through a commercial finite element analysis tool. The natural frequency of Elbow increased very slightly as internal pressure increases. Meanwhile, the frequency of Elbow decreased as temperature increases. It is shown that frequency deviation caused by temperature was greater than that caused by pressure. As the length of Elbows increases, frequency deviation by temperature stew rapidly, but frequency deviation by pressure was not so high. It is concluded that more concern needs to be focused on temperature rather than on pressure in terms of natural frequency.

  • PDF

상용 버스용 알루미늄 시트 프레임의 개발에 관한 연구 (A Study on the Development of Aluminum Seat Frame for Commercial Bus)

  • 우호광;이상복;김상범;김헌영
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.91-100
    • /
    • 2004
  • This study presents the development of a new aluminum seat frame for the commercial bus. Back moment and seat belt anchorage analysis of the conventional steel seat frame was conducted as a base model. Effective aluminum section dimensions for aluminum pipe were calculated from equivalent stiffness and equivalent weight study. Back moment and seat belt anchorage strength with the developed aluminum seat frame were compared to those of the base model. Additionally, to pass the fatigue test, shape modification of side frame assembly was conducted. From this study we could reduce the weight of seat frame more than 5 kg. And the current analysis model and procedure can provide useful informations in designing a new commercial car seat and can reduce the overall design cost and time.

단순 열전달 모델을 이용한 히트파이프의 열전달 성능특성에 관한 연구 (Heat transfer characteristics of the heat pipe using simplified heat transfer model)

  • 서재형;방유마;서이수;이무연
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.15-20
    • /
    • 2015
  • 본 연구의 목적은 전기동력 자동차의 전기-전자 장비들을 효과적으로 냉각시키면서 자체적으로 에너지 소비를 최소화 시킬 수 있는 노력의 일환으로, 단순 열전달 모델을 이용하여 윅이 있는 히트파이프의 열전달 및 유동 특성을 고찰하는 것이다. 이를 위하여 히트파이프는 COMSOL프로그램을 이용하여 해석하였고, 작동유체로 물을 이용하였다. 또한, 히트파이프의 속도 및 온도 특성을 히프파이프 길이에 따라 해석하였고, 국소 및 평균 Nu수를 계산하였다. 결과적으로, 히트파이프의 관성력은 가열면과 냉각면의 온도차에 의하여 발생하였다. 히트파이프내 열전달은 가열면에서 냉각면으로 발생하고 히트파이프 중앙으로 갈수록 증가하였다. 더불어, 가열면의 Nu수는 최대 4.47로 나타났으며, 평균 Nu수는 1.88이고, 냉각면의 Nu수는 최대 0.7로 나타났으며, 평균 Nu수는 0.1이다.

주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책 (Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header)

  • 김연환;배용채;이영신
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.