• Title/Summary/Keyword: Commercial Buildings

Search Result 446, Processing Time 0.038 seconds

Identifying torsional eccentricity in buildings without performing detailed structural analysis

  • Tamizharasi, G.;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • v.23 no.3
    • /
    • pp.283-295
    • /
    • 2022
  • Seismic design codes permit the use of Equivalent Static Analysis of buildings considering torsional eccentricity e with dynamic amplification factors on structural eccentricity and some accidental eccentricity. Estimation of e in buildings is not addressed in codes. This paper presents a simple approximate method to estimate e in RC Moment Frame and RC Structural Wall buildings, which required no detailed structural analysis. The method is validated by 3D analysis (using commercial structural analysis software) of a spectrum of building. Results show that dynamic amplification factor should be applied on torsional eccentricity when performing Response Spectrum Analysis also. Also, irregular or mixed modes of oscillation arise in torsionally unsymmetrical buildings owing to poor geometric distribution of mass and stiffness in plan, which is captured by the mass participation ratio. These irregular modes can be avoided in buildings of any plan geometry by limiting the two critical parameters (normalised torsional eccentricity e/B and Natural Period Ratio 𝜏 =T𝜃/T, where B is building lateral dimension, T𝜃 uncoupled torsional natural period and T uncoupled translational natural period). Suggestions are made for new building code provisions.

The Novel Configuration of Integrated Network for Building Energy System (빌딩 에너지시스템 통합네트워크 구축에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.229-234
    • /
    • 2008
  • The new millennium has started with several innovations driven by fast evolution of the technologies in energy sector. A strong impulse towards the diffusion of new economical efficient technologies regulatory incentives related to energy production from renewable source and a small scale building trigeneration and to promotion of more sustainable environmental-friendly generation solutions, the evolution of electricity markets, more and more binding local emission constraints, and the need for improving the security of supply to reduce the energy system vulnerability. The 24 percentage energy quantify of total energy consumption consumes in commercial buildings and residential houses and the 30% portion of total $CO_2$ emissions covers also in the commercial buildings and residential houses sector. To cope with efficiently this energy sinuation in building sector, Building microgrid or building tooling, heating & power(BCHP) system has been interested in recent day due to meeting thermal and electric energy requirements efficiently and with appropriate energy quality. A multi agent system is a collective of intelligent agents that communicate with each other and work cooperatively to achieve common goals. Also, it is to medicate and coordinate communication between Control Areas and Security Coordinators for teal-time control of the BCHP system and the power pid. In this new circumstance, it is very important to integrate the power and energy delivery system and the information system(communication, networks, and intelligent equipment) that controls it. Therefore, development of smart control modules with open communication protocol and seamlessly interchange the data and information between control network and data network including extranet and intranet give a great meanings. We designed and developed the TCP/IP-CAN IED agent modules and ModBus./LonTalk/(TCP/IP) IED agent ones to configure the multi-agent system based smart energy network of commercial buildings and also intelligent algorithms for inverter fault diagnostics which ran be operated in control level or agent level network.

  • PDF

A Study on the Causes for Declining of Business Area in the Old Downtown of Jeju-si - Focused on a Physical Situation of Land Use and Buildings - (제주시 구도심 상권의 쇠퇴 원인에 관한 연구 -토지이용 및 건축물 등의 물리적 현황을 중심으로-)

  • Cha, Ho-Cheol;Park, Chul-Min
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The aim of this thesis is to present why the business district of old downtown in Jejusi collapsed and what sort of problems caused by that as collecting objective data, which help us to comprehend how the commercial zone has been decaying, on the physical state of the specific area near 'Sinheungro' and 'Chilsungro', which are main commercial sites in the downtown, and analysing it. Firstly It was revealed that most land investigated was property in which structure was able to built or poor land within $60m^2$. This was caused by increasing in land value and high density in space use so that the area did not develop. Secondly, In addition to be low density, most of buildings in 'Sinheungro' and 'Chilsungro' were so old and inefficient - the old buildings were abandoned without improving due to expensive rent and complicated property rights. Thirdly, According to the survey accomplished, major commercial facilities in the area have struggled with the continuous recession in their business. It was the inevitable result of not having an effective alliance with surrounding retail shops and a lack of a strategic action for satisfying consumers desire or adapting to new shopping patterns. Fourthly, Infrastructure in the site was ruining the beauty of the urban landscape as well as bringing on bad access to the inner city as not having improved enough. Furthermore, many administration departments which were in charge of each infrastructure existed. This was resulted from not considering unification between each infrastructure and regional characteristics of the local community.

From Fragmented Development to Three-Dimensional and Coordinated Development - Research on Renewal Strategies of Existing Underground Commercial Space in Harbin

  • Xue, Minghui;Su, Yiming;Hu, Jiayu
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.17-28
    • /
    • 2021
  • In Harbin, a network of underground commercial spaces has been developed to occupy spaces that were originally created as civil defense shelters. With the gradual extension of the local metro rail system, the existing underground commercial space is no longer an isolated regional development, but a space that represents "three-dimensional city" and coordinated development taking place in many Chinese cities. Based on the analysis of the unique development process taken in underground space of Harbin, this paper summarizes three characteristics of its early model of "fragmented development" of underground space. By conducting a comprehensive field research and survey, the researchers analyzed 472 questionnaires related to the development trend, and proposed multi-level synergistic elements for the renewal and development of underground commercial space. The paper concludes by discussing the trend of "three-dimensional and collaborative development," suitable for the development needs of the new era, and the corresponding development strategies for the renewal of underground space.

The Use of Landscape Greenery Surrounding Commercial Buildings in Seoul (서울시 일부 상업용 건물 수목의 입지환경)

  • Lee, Eun-Heui;Jang, Ha-Kyung;Ahn, Geun-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.5
    • /
    • pp.73-81
    • /
    • 2008
  • The purpose of this study is to create a database of the use of landscape greenery that surrounds commercial buildings in Seoul. The method of this study was: to review preceding studies and related laws, survey areas, measure trees, and analyze the results. The 20 representative sites were specifically investigated to measure the width, direction, and environment of planting conditions. To analyze the greens adjacent to the building, the greens were divided into three types: front greenery, side greenery, and rear greenery. The study surveyed the distance from trees to adjacent buildings, and their planting conditions. The results of this study are as follows. First, 45% of the front greenery and 30% of the rear greenery were not established, but 19 of the 20 side greens were. Second, 13 of the 44 green areas adjacent to commercial buildings were under 1m in width. Most side greenery was belt -shape and unrelated to the features of the site or building. Third, the average distance from trees to buildings was 0.76m, indicating that most trees were planted too close to the buildings. Fourth, of the 30 trees utilized, the species breakdown was: 8 evergreen trees, 15 deciduous trees, and 7 shrubs. For the most part, planting patterns were similar for all species. Fifth, most sites were ill-suited to tree growth, because crown shape, planting conditions, and light conditions, etc., had not been considered. Based on these results, it is suggested that more specific, subdivided standards for planting conditions should be established. For example, building plans should include a green area that is at least one meter in width. In addition, according to the location and type(closing/opening) of the greenery adjacent to the buildings, suitable management programs and supervision protocol should be adopted.

A Study on the Characteristics of Space Utilization after converting of Residential District in a New Development Area - Focused on Dunsan of Daejeon City - (신개발지 일반주거지역의 용도전환시 공간변용 특성에 관한 연구 - 대전 둔산 신시가지를 중심으로 -)

  • Park, Jung-A;Kang, In-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • The purpose of this study is to find the characteristics of space utilization and the problems that follows after converting in a new developmental residential area. This study used the content-analysis method and analysis was made on the floor plans for 95 different conversion cases. Above all, 190 unit plans (the unit plans for conversion before and after) were analyzed. The results of this study were as follows; 1) There were 8 types of conversion according to such usages as residential, commercial and residential-commercial buildings. 2) In the case of conversions, from residential to commercial, there was a tendency each floor was integrated to exclusive use for commercial or commercial with small portions of residential usage. And in the case of conversions from commercial to residential, there was a tendency that all space of each floor were changed to exclusive usages for residential purposes. 3) In case of usage conversion from commercial to residential, there were constraints for balcony installation, because of its original lot-structure and building equipments. Also, when the basement was converted for residential purpose, there was no possibility for an extra lighting or ways to ventilate the area.

A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area (메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로)

  • Baek, Sang Yeol;Kim, Gi Soo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.

The Regionally Specific Residential Characteristics of ′Residential-Commercial Mixed Use Buildings′ in Seoul (서울시 주상복합건물의 지역별 주거 특성)

  • 정은진
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.5
    • /
    • pp.741-753
    • /
    • 2003
  • This study begins with paying attention to the agglomeration of 'Residential-Commercial Mixed Use Buildings(hereafter, R-C MU Buildings)', which tend to be a high grade and large sized building cluster at various neighboring areas in Seoul. The purpose of this study is to understand the relationship between emerging new housing type and residential area by analyzing the characteristics of residential neighborhood that is mainly created by R-C MU Buildings. For this purpose, the specialization and the regional characteristics(in connection with the hierarchy in urban spatial structure) of R-C MU Building's residential neighborhood were analyzed. In the end, the specific type of housing reveals the tendency to be differentiated in terms of income, education and occupation related with housing and residential area. And the residential characteristics also seem to be different according to the regions based on the central place hierarchical structure. It means that the social and class factors are important in choosing house, but the characteristics of the neighborhood area play an important role in the selection of resident area. Finally, the location of certain type of housing can influence the selecting process of residence and it can also determine the characteristics of the resident area in turn.

Environment Adaptive Emergency Evacuation Route GUIDE through Digital Signage Systems

  • Lee, Dongwoo;Kim, Daehyun;Lee, Junghoon;Lee, Seungyoun;Hwang, Hyunsuk;Mariappan, Vinayagam;Lee, Minwoo;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.90-97
    • /
    • 2017
  • Nowadays, the most of commercial buildings are build-out with complex architecture and decorated with more complicated interiors of buildings so establishing intelligible escape routes becomes an important case of fire or other emergency in a limited time. The commercial buildings are already equipped with multiple exit signs and these exit signs may create confusion and leads the people into different directions under emergency. This can jeopardize the emergency situation into a chaotic state, especially in a complex layout buildings. There are many research focused on implementing different approached to improve the exit sign system with better visual navigating effects, such as the use of laser beams, the combination of audio and video cues, etc. However the digital signage system based emergency exit sign management is one of the best solution to guide people under emergency situations to escape. This research paper, propose an intelligent evacuation route GUIDE that uses the combination centralized Wireless Sensor Networks (WSN) and digital signage for people safety and avoids dangers from emergency conditions. This proposed system applies WSN to detect the environment condition in the building and uses an evacuation algorithm to estimate the safe route to escape using the sensor information and then activates the signage system to display the safe evacuation route instruction GUIDE according to the location the signage system is installed. This paper presented the prototype of the proposed signage system and execution time to find the route with future research directions. The proposed system provides a natural intelligent evacuation route interface for self or remote operation in facility management to efficiently GUIDE people to the safe exit under emergency conditions.

Damage and vibrations of nuclear power plant buildings subjected to aircraft crash part II: Numerical simulations

  • Li, Z.R.;Li, Z.C.;Dong, Z.F.;Huang, T.;Lu, Y.G.;Rong, J.L.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3085-3099
    • /
    • 2021
  • Investigations of large commercial aircraft impact effect on nuclear power plant (NPP) buildings have been drawing extensive attentions, particularly after the 9/11 event, and this paper aims to numerically assess the damage and vibrations of NPP buildings subjected to aircrafts crash. In Part I of present paper, two shots of reduce-scaled model test of aircraft impact on NPP were conducted based on the large rocket sled loading test platform. In the present part, the numerical simulations of both scaled and prototype aircraft impact on NPP buildings are further performed by adopting the commercial program LS-DYNA. Firstly, the refined finite element (FE) models of both scaled aircraft and NPP models in Part I are established, and the model impact test is numerically simulated. The validities of the adopted numerical algorithm, constitutive model and the corresponding parameters are verified based on the experimental NPP model damages and accelerations. Then, the refined simulations of prototype A380 aircraft impact on a hypothetical NPP building are further carried out. It indicates that the NPP building can totally withstand the impact of A380 at a velocity of 150 m/s, while the accompanied intensive vibrations may still lead to different levels of damage on the nuclear related equipment. Referring to the guideline NEI07-13, a maximum acceleration contour is plotted and the shock damage propagation distances under aircraft impact are assessed, which indicates that the nuclear equipment located within 11.5 m from the impact point may endure malfunction. Finally, by respectively considering the rigid and deformable impacts mainly induced by aircraft engine and fuselage, an improved Riera function is proposed to predict the impact force of aircraft A380.