• Title/Summary/Keyword: Combustion Property

Search Result 177, Processing Time 0.026 seconds

Characteristic Property of Combustion and Internal Ballistics of Triple-Based Propellant according to Particle Size of RDX (RDX 입도에 따른 다기추진제의 연소 및 강내탄도 특성)

  • Soojung Son;Wonmin Lee;Woojin Lee;Daegeon Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.428-435
    • /
    • 2024
  • The important factors in the design of the gun propellant are impetus, flame temperature and pressure. In this paper, we considered a nitrocellulose based propellant composition that replaced sensitive NG(Nitroglycerin) with RDX(Cyclotrimethylenetrinitramine) and DEGDN(Diethylene glycol dinitrate) which high energy and low sensitivity. Particle size and content of RDX are the two main factors that affect the burning stability of RDX-based propellants. Among them, the characteristics of the propellant according to the particle size of RDX were confirmed. The relative combustion rate(R.Q., Relative Quickness) of the propellant changed according to the RDX particle size, and internal ballistics of properties of propellant were also varied. The particle size of RDX can be confirmed as a major factor in the combustion and internal ballistics characteristics of the propellant.

A Study on Mechanical Property of SM53C Steel by High Frequency Induction Hardening (고주파열처리 SM53C강의 기계적 성질에 관한 연구)

  • Kim, Hwang-Soo;Kim, Jung-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.6
    • /
    • pp.7-15
    • /
    • 2010
  • Recently, with the high performance and efficiency of machine, there have been required the multi-functions in various machine parts, such as the heat resistance, the abrasion resistance and the stress resistance as well as the strength. Fatigue crack growth tests were carried out to investigate the fatigue characteristics of high carbon steel (SM53C) experienced by high-frequency induction treatment. The Cam nose part of the Automobile's Cam shaft is strongly bumped with rocker arm or valve-lift. Therefore abnormal wear such as unfair wear and early wear occur in the surface. This abnormal wear causes a defect that bad timing open and close actions of the engine valve happen in the combustion chamber so the fuel gas will be combustion imperfect. Therefore, the cam shaft demands high hardness and wear resistance. In this study, high frequency heat treatment has been accomplished while wear test for material SM53C.

An Experimental Study for Performance Evaluation of a Ceramic Heat Exchanger (세라믹 열교환기의 성능평가를 위한 실험적 연구)

  • Choi, Hyun-Soo;Shin, Dong-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2011
  • Exhaust gas of an industrial furnace used at such as metallurgy or ceramic manufacturing usually contains thermal energy with high temperature which can be recycled by heat exchanger. However, when the temperature of the exhaust gas is high such as more than $1,000^{\circ}C$, ordinary metallic heat exchanger cannot fully recover the heat due to the limitation of operating temperature depending on the material property. In the present study, a compact ceramic heat exchanger of cross flow type is introduced and evaluated by heat exchange rate and operating temperature. The ceramic heat exchanger can endure the gas temperature more than $1,300^{\circ}C$, and its volumetric heat exchanging rate exceeds 1 MW/$m^3$. The experimental data is also compared with the previous numerical result which shows reasonable agreement. Meanwhile, the gas leakage rate is measured to be about 3~4%, and heat loss to environmental air is about 23~26% of the fuel energy.

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

Creation of Diamond/Molybdenum Composite Coating in Open Air

  • Ando, Yasutaka;Tobe, Shogo;Tahara, Hirokazu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1313-1314
    • /
    • 2006
  • For improvement of wear resistance property of atmospheric thermal plasma sprayed molybdenum (Mo) coating, diamond deposition on the atmospheric plasma sprayed molybdenum coating by the combustion flame chemical vapor deposition (CFCVD) has been operated. In this study, to diminish the thermal damage of the substrate during operation, a thermal insulator was equipped between substrate and water-cooled substrate holder. Consequently, diamond particles could be created on the Mo coating without fracture and peeling off. From these results, it was found that this process had a high potential in order to improve wear resistance of thermal sprayed coating.

  • PDF

The Study on the Flame Retardancy of Rubber according to $Al(OH)_3$ Addition Using Experimental Design Method (실험 계획법을 이용한 $Al(OH)_3$ 첨가량에 따른 고무의 난연 특성 연구)

  • Min, Young-Cho;Kang, Yun-Jin;Kim, Ki-Young;Kang, Kyong-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2008
  • The effect of $Al(OH)_3$ on physical, thermal, and retardant property of rubber was studied. It was analyzed by statistical experimental design method with one way array to confirm the effect of factors. Physical characteristics, thermal pyrolysis temperature, and combustion time were considered as the properties. The amount of $Al(OH)_3$ addition was chosen as significant parameter. As the result of ANOVA analysis, thermal pyrolysis temperature increased and combustion time decreased with increasing of $Al(OH)_3$.

Combustion property comparison of rubber foam insulator by the variation of the glass fiber cross-Al foil thickness (Glass fiber cross-Al foil 차단막 두께에 따른 고무발포단열재 연소특성)

  • Cho, Hee-Ki;Lee, Duck-Hee;Lee, Cheul-Kyu;Paek, Min;Jung, Boung-Cheul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.293-298
    • /
    • 2005
  • Insulator is being used for material of railroad vehicles as a barrier of heat and noise. But it shows various fire properties in case of fire. In this study, we compared smoke density(Ds) values of rubber foams with the different thickness of glass fiber cross-Al foil according to the standard of ASTM E 662. The result showed that the insulator and barrier property played an important role in decreasing the value of smoke density

  • PDF

The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material (외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Kim, Jung-Hyun;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.85-91
    • /
    • 2012
  • To reduce human life and property damage at the fire in a building, it is most critical to control flame spread in the early stage. Fire spread prevention measure generally includes fire resistance performance securing of structure member in the arson zone and use limitation based on combustion performance of finishing material. The latter is most fundamental fire safety design to determine flame spread, but domestic combustion test determines combustion performance by specimen sized fire test method. Thus, there are many restrictions in the determination of combustion performance by composite material such as sandwich panel. Especially, outer finishing material uses a variety of composite material such as dry bit, aluminum composite panel, and metal panel compared to inner finishing material. Therefore, this study would determine vertical fire spread features by a full scaled fire experiment through the test method of ISO 13785-2, an international test standard.

Combustion Characteristics of Benzene over $LaMnO_3$ Perovskite-type Catalysts Prepared Using Microwave-assisted Process (마이크로파 공정으로 제조된 $LaMnO_3$ 페롭스카이트형 촉매에서 벤젠의 연소반응)

  • Jung, Won Young;Hong, Seong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.507-512
    • /
    • 2013
  • Perovskite-type oxides were successfully prepared using microwave-assisted process, and by XRD, XPS, BET, and $H_2-TPR$. Their catalytic activities for the combustion of benzene were also examined. Most of catalysts studied showed the perovskite crystalline phase with the particle size of 21~35 nm. The $LaMnO_3$ catalyst showed the highest activity and the conversion reached almost 100% at $250^{\circ}C$. The catalysts prepared by microwave-assisted process showed higher activity compared to those prepared sol-gel method. In addition, the catalytic activity was increased with an increase of calcination temperature of $LaMnO_3$-type catalyst. The TPR results on the measurement of redox property showed a good correlation with the order of catalytic activity on the benzene combustion reaction.

A Study on the Combustion Test of Artificial Turf Installed on Field (실외에 설치되는 인조잔디의 연소시험에 관한 연구)

  • Min, Se-Hong;Kim, Yeon-Hwang
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.48-53
    • /
    • 2014
  • In this study, we would evaluate fire risk by domestic standard for artificial turf installed on field and roofs. Today domestic regulation for artificial turf only applies to outdoor uses and especially KS M 3888-1 has compulsion but limited to school athletic facilities. Indoor regulation complying with National Emergency Management Agency (No. 2012-35) was enacted as recommendations. Thus this study did combustion test of artificial turf installed on field. Analyzed result by 45 degree flammability test, standard was inadequate to judge the fire risk so we compared and analysed its characteristic through combustion test of flame retardant finishing carpet used as flooring. Test and assessment result of its ignitionability by 45 degree flammability test showed that carpet was satisfied with flame retardant finishing performance standard contrary to artificial turf. For this reason, by conducting cone calorimeter test, the combustion property after ignition would be analyzed and evaluated and then this study will suggest a countermeasure for strengthening standard.