• Title/Summary/Keyword: Combined on-board signal system

Search Result 13, Processing Time 0.017 seconds

Study of 3 dimensional wide area continuous laser micro patterning (3차원 대면적 연속 마이크로 레이저 패터닝을 위한 연구)

  • Kim, Kyunghan;Sohn, Hyonkee;Lee, Jaehoon
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.1-5
    • /
    • 2015
  • For continuous laser micro patterning on three-dimensional free form surface, innovative laser system is developed. The two axis galvanometer is combined with the dynamic focusing unit to increase optical distance. Also, it is synchronized with the 3 axis mechanical system. To determine laser machining sequence, laser CAM system is developed. It can make possible of 3D surface micro patterning under $25{\mu}m$ pattern width. The uniformity of pattern width is about 2.8% and it is validated that focal plane is well conserved by the dynamic focusing unit. Velocity and positional information of 1 axis is stage is fed to the scanner control board by the encoder signal and it makes possible real time synchronization. With this system, possible patterning volume is enlarged from $40{\times}40mm^2$ to $40{\times}120{\times}30mm^3$.

Development and Performance Testing of a Time-resolved OSL Measurement System

  • Hong, Duk-Geun;Kim, Myung-Jin
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Background: Time-resolved optically stimulated luminescence (TR-OSL) is a very useful method for calculating the lifetimes of crystalline quartz and feldspar. Materials and Methods: A compact TR-OSL system was developed, comprising a heater assembly manufactured using Kanthal wire, 2 powerful blue light-emitting diodes (LED, LXHL-PB02) for optical stimulation equipped with VIS liquid light guides, and a photomultiplier tube combined with an optical filter for luminescence detection. A pulse generated from the data acquisition board (NI PCI 6250) was used to initiate on/off signals in LED and TR-OSL measurements. Results and Discussion: The TR-OSL and background signals measured using this TR-OSL system using quartz samples were very similar to those reported in a previous study. Additionally, the lifetimes of the build-up and TR-OSL signals were calculated as $27.4{\pm}2.2{\mu}s$ and $30.3{\pm}0.6{\mu}s$, respectively, in good agreement with the findings of a previous study. Conclusion: It was concluded that the developed TR-OSL system was very reliable for TR-OSL signal measurements and lifetime calculations.

Study on the methods of extracting Electrical parameters on PCB design process (PCB 설계에서 기판의 전기적 파라미터 추출 기법 고찰)

  • 최순신
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1533-1540
    • /
    • 2001
  • In this paper, we described extraction method of electrical parameters and modeling method of PCB nets on PCB design process. To analyze electrical characteristics of real PCB structure, we selected a cache memory system as an experimental board and designed 6 layer PCB substrate. For extraction of the electrical parameters, we divided circuit elements into the components of conductor types which are wires, via holes, BGA balls etc. and combined the calculated value by real net structure to modeling the PCB nets. We analyzed the electrical characteristics of the PCB nets with the simulation tools of SPICE and XNS. The simulation analysis has shown that the maximum signal delay was 2.6ns and the maximum crosstalk noise was 281 mV and we found that the designed substrate was adequate to system specification.

  • PDF