• Title/Summary/Keyword: Combined cycle system

검색결과 315건 처리시간 0.027초

저온 열원의 활용을 위한 칼리나/흡수냉동 복합사이클의 성능 해석 (Performance Analysis of a Combined Cycle of Kalina and Absorption Refrigeration for Recovery of Low-Temperature Heat Source)

  • 김경훈;고형종;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.490-496
    • /
    • 2018
  • Recently, the power and refrigeration cogeneration based on Kalina cycle has attracted much attention for more efficient utilization of low-grade energy. This study presents a thermodynamic performance analysis of a cogeneration cycle of power and absorption refrigeration based on Kalina cycle. The cycle combines Kalina cycle (KCS-11) and absorption cycles by adding a condenser and an evaporator between turbine and absorber. The effects of ammonia mass fraction and separation pressure were investigated on the system performance of the system. Results showed that the energy utilization of the system could be greatly improved compared to the basic Kalina cycle.

복합화력 제어가능 운전 파라미터의 실시간 영향산출 기법 (A Real-time Calculation Method on Performance Impact of Controllable Operation Parameters for Combined Cycle rower Plant)

  • 주용진;박종호
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.67-73
    • /
    • 2006
  • 본 논문에서는 복합화력 발전시스템을 대상으로 온라인 성능감시시스템을 적용함에 있어 제어가능 운전 파라미터의 실시간 영향산출 기법을 고안하였다. 이 기법은 가스터빈 인입필터 차압, 압축기 효율 등과 같은 운전 파라미터에 대해 기대치와 현재치의 편차로 인해 얼마만큼 성능에 영향을 미치는가를 정량적으로 산출하여 사용자가 즉각적으로 성능향상을 위한 운전조작이 가능하도록 조치할 수 있는 성능관리지표로서 활용된다.

IGCC 발전 플랜트에서 복합발전공정-공기분리장치의 연계에 관한 열역학적 성능 평가 (Thermodynamic Performance Evaluation of an Integration Design between the Combined-cycle and Air Separation Unit in an IGCC Power Plant)

  • 원온누리;김현정;박성구;나종문;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.49-51
    • /
    • 2012
  • In this paper, the integration issue, such as an air-side integration design between the gas turbine and air separation unit, is described and analyzed by the exergy and energy balance of the combined-cycle power block in an IGCC power plant. The results showed that the net power of the system was almost same, but that of the gas turbine was decreased as the integration degree increased. The highest exergy loss was occurred in the combustor of gas turbine, which was affected by the chemical reaction, heat conduction, mass diffusion, and viscous dissipation.

  • PDF

복합발전기 조합별 증분비 곡선 재설정에 관한 연구 (A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination)

  • 홍상범;최준호
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

복합화력발전소 내 수소연료 적용 시 누출 사고에 대한 피해영향범위 분석: 지역별 환경 특성 영향에 기반하여 (Consequence Analysis on the Leakage Accident of Hydrogen Fuel in a Combined Cycle Power Plant: Based on the Effect of Regional Environmental Features)

  • 박희경;이민철
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.698-711
    • /
    • 2023
  • Consequence analysis using an ALOHA program is conducted to calculate the accidental impact ranges in the cases of hydrogen leakage, explosion, and jet fire in a hydrogen fueled combined cycle power plant. To evaluate the effect of weather conditions and topographic features on the damage range, ALOHA is executed for the power plants located in the inland and coastal regions. The damage range of hydrogen leaked in coastal areas is wider than that of inland areas in all risk factors. The obtained results are expected to be used when designing safety system and establishing safety plans.

자동 생산을 위한 윈셀 미니팩토리 (One-Cell Minifactory for Automated Manufacturing)

  • 김진오
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.300-300
    • /
    • 2000
  • Reduced life-cycle and scale of electronic products make the conventional automated manufacturing system difficult to keep on competitiveness in these days. Reduced life-cycle requires an agile adaptation of manufacturing to new products and reduced scale requires enhanced precision as well as high speed. In this research, We propose a new concept called as "One-Cell Minifactory" in which various processes are combined to produce final modules or products and human interaction can be combined easily. We hope the proposed concept can guide new developments of automated manufacturing in electronics, optics and bio-engineering.

  • PDF

Gas Turbine Data Acquisition and Monitoring System for Combined Cycle Power Plant

  • Kang, Feel-Soon
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.405-410
    • /
    • 2008
  • This paper presents a data acquisition and monitoring system for a gas turbine. The proposed system entitled C-Tune DAS plays an important role to make an analysis of the real-time operation of the gas turbine under maintenance. The designed LabVIEW based software is divided into three parts according to their original functions, i.e., data acquisition, data analysis with display, and data storage. The data acquisition part receives data from a PMS (Plant Management System) server and two cFPs (Compact-Field Point). To verify the validity of the developed system, it is applied to gas turbines in the combined cycle power plant in Korea.

LNG 냉열을 이용하는 암모니아-물 랭킨 사이클과 유기 랭킨 사이클의 열역학적 성능 특성 해석 (Thermodynamic Performance Analysis of Ammonia-Water Rankine Cycle and Organic Rankine Cycle Using Cold Energy of LNG)

  • 김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제31권4호
    • /
    • pp.363-371
    • /
    • 2020
  • Recently, the technologies to utilize the cold energy of liquefied natural gas (LNG) have attracted significant attention. In this paper, thermodynamic performance analysis of combined cycles consisting of ammonia Rankine cycle (AWR) and organic Rankine cycle (ORC) with LNG Rankine cycle to recover low-grade heat source and the cold energy of LNG. The mathematical models are developed and the effects of the important system parameters such as turbine inlet pressure, ammonia mass fraction, working fluid on the system performance are systematically investigated. The results show that the thermal efficiency of AWR-LNG cycle is higher but the total power production of ORC-LNG cycle is higher.

연소전 처리를 이용한 탄소포집이 가스터빈 복합화력 플랜트의 성능에 미치는 영향 (Effect of Carbon Capture Using Pre-combustion Technology on the Performance of Gas Turbine Combined Cycle)

  • 윤석영;안지호;최병선;김동섭
    • 한국수소및신에너지학회논문집
    • /
    • 제27권5호
    • /
    • pp.571-580
    • /
    • 2016
  • In this paper, performance of the gas turbine combined cycle(GTCC) using pre-combustion carbon capture technology was comparatively analysed. Steam reforming and autothermal reforming were used. In the latter, two different methods were adopted to supply oxygen for the reforming process. One is to extract air form gas turbine compressor (air blowing) and the other is to supply oxygen directly from air separation unit ($O_2$ blowing). To separate $CO_2$ from the reformed gas, the chemical absorption system using MEA solution was used. The net cycle efficiency of the system adopting $O_2$ blown autothermal reforming was higher than the other two systems. The system using air blown autothermal reforming exhibited the largest net cycle power output. In addition to the performance analysis, the influence of fuel reforming and carbon capture on the operating condition of the gas turbine and the necessity of turbine re-design were investigated.

관류형 열회수 증기발생기와 증기터빈 시스템의 성능해석 (Performance Analysis of Once-through HRSG and Steam Turbine System)

  • 양진식;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.872-877
    • /
    • 2001
  • This study analyzed the design performance of the bottoming system of combined cycle power plants adopting a single-pressure once-through heat recovery steam generator with reheat. A computer program was constructed and parametric analyses were carried out to present the criteria for determining the reheat pressure and the location of the starring point of the reheater in the HRSG. The performance of the bottoming system was presented for the range from high subcritical to supercritical pressures. It was founded that the power of the bottoming system can be as high as that of the present triple-pressure bottoming system even with a higher exhaust gas temperature. A requirement for this high performance is a proper arrangement of the reheater.

  • PDF