• Title/Summary/Keyword: Combined Two Probe Method

Search Result 13, Processing Time 0.027 seconds

An experimental study on the wake structure behind a van type vehicle (Van형 자동차의 후류구조에 대한 실험적 해석(와류 형성을 중심으로))

  • 성봉주;장병희
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.51-59
    • /
    • 1988
  • The wake structure behind a van type vehicle was studied experimentally with a 5-hole yawhead probe. Through an effective calibration method of the 5-hole yawhead probe, the flow properties such as velocity vector, total pressure and static pressure were obtained on two cross sections within the wake. These results combined with the surface flow visualization performed in the previous study, yielded some information about the wake structure. When the model was placed in a stream with zero yaw angle, two counter rotating vortices were observed behind the model which pull down the surface flow on each side of the model. With increasing the yaw angle, the surface flow on the windward side changed to divide the flow in two directions, one flows upward on the upper part and the other flows downward on the lower part of the windward side. Hence a new weak vortex was created on the upper windward side, which resulted 3 vortices within the wake. The size and the strength of the vortices increased with yaw angle.

  • PDF

Development of Measurement System for Quantitative Measurement of Cantilever in Atomic Force Microscopy (원자간격 현미경의 캔틸레버의 정량적 특성평가를 위한 계측 시스템 개발)

  • Kweon, Hyun-Kyu;Nam, Ki-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.22-27
    • /
    • 2007
  • In this study, the two methods of stiffness measurement(Spring constant) of cantilever were proposed for quantitative measurement in Atomic Force Microscopy(AFM). As the 1st method for the measurement of stiffness, the probe method, which is used in the measurement of the semiconductor mechanical and electrical properties, was applied to the measurement of the cantilever. Experiments by the probe method were performed finding the resistance value of cantilever. As the results, the resistance was measured differently along with the dimension and the thickness of cantilever that determined the stiffness(spring constant) of the lever. As the 2nd method, the vibration characteristics(Dunkerley expression) is used to obtain the stiffness of the complex structure which is combined by AFM cantilever and the standard cantilever. We measured the resonant frequency from the complex structure using the micro stages and stereo microscope. As the results, we confirmed that the vibration characteristics(Dunkerley expression) is effected the micro complex structure of AFM cantilever.

  • PDF

Thermal Diffusivity Evaluation of Backfilling Materials for Horizontal Ground Heat Exchanger Using Single-Probe Method (단일 탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 산정)

  • Sohn, Byong-Hu;Choi, Hang-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.356-364
    • /
    • 2011
  • Storage and transfer heat in soils is governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the evaluation results of the thermal diffusivity of soils (silica, quartzite, limestone, sandstone, granite, and two masonry soils used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities using single-probe method and (ii) use the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Combined algorithm with and improved model for the thermal conductivity of soils and the constituent equation provides accurate estimates of the soil thermal diffusivity.

Measurement and Active Compensation for 3-DOF Motion Errors of an Air Bearing Stage with Magnetic Preloads (자기예압 공기베어링 스테이지의 3 자유도 운동오차 측정 및 능동 보정)

  • Ro, Seung-Kook;Kim, Soo-Hyun;Kwak, Yoon-Keun;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.109-117
    • /
    • 2009
  • This paper presents a linear air bearing stage with compensated motion errors by active control of preloads generated by magnetic actuators with combination of permanent and electromagnets. A 1-axis linear stage motorized with a linear motor with 240mm of travel range is built for verifying this design concept and tested its performances. The three motions of the table are controlled with four magnetic actuators driven by current amplifiers and a DSP based digital controller. Three motion errors were measured combined method with laser interferometer and two-probe method with $0.085{\mu}m$ of repeatability for straightness error. The measured motion errors were modeled as functions of the stage position, and compensation were carried out with feedforward control because the characteristics of the motion control with magnetic actuators are linear and independent for each degree-of-freedoms. As the results, the errors were reduced from $1.09{\mu}m$ to $0.11{\mu}m$ for the vertical motion, from 9.42 sec to 0.18 sec for the pitch motion and from 2.42 sec to 0.18 sec for roll motion.

Polarity Probing Two-Photon Fluorophores Based on [2.2]Paracyclophane

  • Woo, Han-Young;Korystov, Dmitry;Jin, Young-Eup;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2253-2260
    • /
    • 2007
  • A series of tetra donor substituted [2.2]paracyclophane-based two-photon absorption (TPA) fluorophores were synthesized in neutral and cationic forms. The imaging activity of overall set of fluorophores was studied by the two-photon induced fluorescence (TPIF) method in a range of solvents. We also measured a clear progression toward a longer photoluminescence lifetime with increasing solvent polarity (intrinsic photoluminescence lifetime, τi: ~2 ns in toluene → 12-16 ns in water). The paracyclophane fluorophores with this unique property can be utilized as an optical polarity probe for the biomolecular substrates. The combined measurement of the two-photon fluorescence microscopy (TPM) cell image and TPIF lifetime can give us a better understanding of the biological processes and local environments in the cells.

Parallelism Measurement for Guide Rails of Precision Machine Tools (정밀 공작기계 안내면의 평행도 측정)

  • Hwang J.H.;Park C.H.;Gao W.;Kim S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.792-795
    • /
    • 2005
  • The guide-ways of precision machine tools are one of important element of machine tools. It has usually a pair of surfaces for constraint of one direction with bearing. In the case of precision machine tools, non-contact bearing such as hydrostatic bearing and aerostatic bearing is adopted usually. In this case, profiles of rails has effect on straightness and the clearance of bearing has effect on stiffness of guide way, which changes to higher if clearance changes to smaller. The clearance is varied along moving table according to relative distance of pair of rails. The relative distance of pair of rail can be divided by three properties. First and second properties are straightness of each pair of rail and bearing pad. And, third is parallelism about pair of rails and pairs of bearing pad. There are several methods for measuring straightness of each surface such as reversal method, sequential two point method, and way straightness. These straightness measuring methods are always acquiring deviation of profile from eliminating linear fitted inclined line and don't have the information of parallelism. Therefore, to get the small clearance for high stiffness, the straightness of rail and bearing pad and parallelism about pair of rails and pair of bearing pads are measured for correction such as regrinding, reassembling and lapping. In this research, new and easy method for measuring parallelism of pair of rails is suggested. Two displacement probe and sensor stage, which is carry on the displacement sensor, are needed. The simulation and experiment was accomplished about pair of horizontal guide way to confirm the measurement of parallelism. And, the third probe is added to measure the straightness of each rails by sequential two point method. From the estimation of combined these two methods, it is confirmed that the profiles of a pairs of rails can be measured.

  • PDF

Development of Two-color Radiation Thermometer for Harsh Environments

  • Mohammed, Mohammed Ali Alshaikh;Kim, Ki-Seong
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.184-194
    • /
    • 2016
  • Many industrial processes require reliable temperature measurements in harsh environments with high temperature, dust, humidity, and pressure. However, commercially-available conventional temperature measurement devices are not suitable for use in such conditions. This study thus proposes a reliable, durable two-color radiation thermometer (RT) for harsh environments that was developed by selecting the appropriate components, designing a suitable mechanical structure, and compensating environmental factors such as absorption by particles and gases. The two-color RT has a simple, compactly-designed probe with a well-structured data acquisition system combined with efficient LabVIEW-based code. As a result, the RT can measure the temperature in real time, ranging from 300 to $900^{\circ}C$ in extremely harsh environments, such as that above the burden zone of a blast furnace. The error in the temperature measurements taken with the proposed two-color RT compared to that obtained using K-type thermocouple readouts was within 6.1 to $1.4^{\circ}C$ at a temperature range from 200 to $700^{\circ}C$. The effects of absorption by gases including $CO_2$, CO and $H_2O$ and the scattering by fine particles were calculated to find the transmittance of the two wavelength bands of operation through the path between the measured burden surface and the two-color probe. This method is applied to determine the transmittance of the short and long wavelength bands to be 0.31 and 0.51, respectively. Accordingly, the signals that were measured were corrected, and the true burden surface temperature was calculated. The proposed two-color RT and the correction method can be applied to measure temperatures in harsh environments where light-absorbing gases and scattering particles exist and optical components can be contaminated.

Identification of the Polymorphisms in IFITM2 and IFITM5 Genes and their Association with Ulcerative Colitis (IFITM2 및 IFITM5 유전자다형성의 발굴과 궤양성대장염의 감수성과의 연관성)

  • Kim, Hun-Soo;Mo, Ji-Su;Alam, Khondoker Jahengir;Park, Won-Cheol;Kim, Keun Young;Chae, Soo-Cheon
    • Journal of Life Science
    • /
    • v.25 no.1
    • /
    • pp.84-92
    • /
    • 2015
  • Interferon inducible transmembrane protein (IFITM) family genes have been implicated in various cellular processes such as the homotypic cell adhesion functions of IFNs and cellular anti-proliferative activities. The present study aimed to investigate whether the polymorphisms of the IFITM2 and IFITM5 genes are associated with susceptibility to UC. We identified a total of thirteen polymorphisms (eleven SNPs and two variations) in the IFITM2 gene and twelve polymorphisms (eleven SNPs and one variation) in the IFITM5 gene, by the direct sequencing method. Genotype analysis in the IFITM2 and IFITM5 SNPs was performed by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and Taq-Man probe analysis, and the haplotype frequencies of IFITM2 and IFITM5 SNPs for multiple loci were estimated using the expectation maximization (EM) algorithm. The genotype and allele frequencies of IFITM2 SNPs, as well as IFITM5 SNPs, in UC patients were not significantly different from those of the healthy controls. We also analyzed the combined frequencies of rs77537847 of IFITM1, rs909097 of IFITM2, and rs56069858 of IFITM5 in the UC patients and the healthy controls. Although the distribution of the major combined genotype frequency did not differ significantly between the healthy controls and the UC patients, the GGT combined frequency in the healthy controls was significantly different from that in the UC patients (P=0.002). This result suggests that the combined genotype of the IFITMs polymorphisms may be associated with a susceptibility to UC and could be a useful genetic marker for UC.

Development of PCR-Based Sequence Characterized DNA Markers for the Identification and Detection, Genetic Diversity of Didymella bryoniae with Random Amplified polymorphic DNA(RAPD)

  • Kyo, Seo-Il;Shim, Chang-Ki;Kim, Dong-Kil;Baep, Dong-Won;Lee, Seon-Chul;Kim, Hee-Kyu
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.130-130
    • /
    • 2003
  • Gummy stem blight pathogen is very difficult not only to monitor the inoculum levels prior to host infection, and also it is destructive and hard to control in field condition. We have applied RAPD technique to elucidate the genetic diversity of the genomic DNA of Didymella bryoniae and also to generate specific diagnostic DNA probe useful for identification and detection. The 40 primers produced clear bands consistently from the genomic DNA of twenty isolates of Didymella bryoniae, and two hundred seventy-three amplified fragments were produced with 40 primers. The combined data from 273 bands was analyzed by a cluster analysis using UPGMA method with an arithmetic average program of NTSYS-PC (Version 1.80) to generate a dendrogram. At the distance level of 0.7, two major RAPD groups were differentiated among 20 strains. RAPD group (RG) I included 8 isolates from watermelon except one isolate from melon. RAPD group (RG) IV included 12 isolates from squash, cucumber, watermelon and melon.. In amplification experiment with SCAR specific primer RG1F-RG1R resulted in a single band of 650bp fragment only for 8 isolates out of 20 isolates that should be designated as RAPD Group 1. However, same set of experiment done with RGIIF-RGIIR did not result in any amplified product.. Our attempts to detect intraspecific diversity of ITS region of rDNA by amplifying ITS region and 17s rDNA region for 20 isolates and restriction digestion of amplified fragment with 12 enzymes did not reveal polymorphic band. In order to develop RAPD markers for RGIV specific primer, a candidate PCR fragment( ≒1.4kb) was purified and Southern hybridized to the amplified fragment RGIV isolates. This promising candidate probe recognized only RGIV isolates

  • PDF

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: II. Practical Classification Method on the Cutting-Line

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Rhee, M.S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 2000
  • To investigate the practical assessing method of pork quality, 302 carcasses were selected randomly to represent commercial conditions and were probed at 24 hr postmortem (PM) by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP), Sensoptic Resistance Probe (SRP) and NWK pH-K21 meter (NpH). Also, filter paper wetness (FPW), lightness (L*), ultimate pH (pHu), subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were recorded. Each carcass was categorized as either PSE (pale, soft and exudative), RSE (Reddish-pink, soft and exudative), RFN (reddish-pink, firm and non-exudative) or DFD (dark, firm and dry). When discriminant analysis was used to sort carcasses into four quality groups the highest proportion of correct classes was 65% by HGP, 60% by MQM, 52% by NpH and 32% by SRP. When independent variables were combined to sort carcasses into groups the success was only 67%. When RSE and RFN groups were merged so that there were only three groups (PSE, RSE+RFN, DFD) differentiating by color MQM was able to sort the same set of data into the new set of three groups with 80% accuracy. The proportions of correct classifications for HGP, NpH and SRP were 75%, 61% and 35% respectively. There was a decline in predication accuracy when only two groups, exudative (PSE and RES) and non exudative (RFN and DFD) were sorted. However, when two groups designated PSE and non-PSE (RSE, RFN and DFD) were sorted then the proportion of correct classification by MQM, HGP, SRP and NpH were 87%, 81%, 71% and 66% respectively. Combinations of variables only increased the prediction accuracy by 1 or 2% over prediction by MQM alone. When the data was sorted into three marbling groups based on SM this was not well predicted by any of the probe measurements. The best prediction accuracy was 72% by a combination of MQM and NpH.