• 제목/요약/키워드: Combinations of sensor

검색결과 58건 처리시간 0.027초

FES 보행을 위한 보행 이벤트 검출 (Gait-Event Detection for FES Locomotion)

  • 허지운;김철승;엄광문
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.170-178
    • /
    • 2005
  • The purpose of this study is to develop a gait-event detection system, which is necessary for the cycle-to-cycle FES control of locomotion. Proposed gait event detection system consists of a signal measurement part and gait event detection part. The signal measurement was composed of the sensors and the LabVIEW program for the data acquisition and synchronization of the sensor signals. We also used a video camera and a motion capture system to get the reference gait events. Machine learning technique with ANN (artificial neural network) was adopted for automatic detection of gait events. 2 cycles of reference gait events were used as the teacher signals for ANN training and the remnants ($2\sim5$ cycles) were used fur the evaluation of the performance in gait-event detection. 14 combinations of sensor signals were used in the training and evaluation of ANN to examine the relationship between the number of sensors and the gait-event detection performance. The best combinations with minimum errors of event-detection time were 1) goniometer, foot-switch and 2) goniometer, foot-switch, accelerometer x(anterior-posterior) component. It is expected that the result of this study will be useful in the design of cycle-to-cycle FES controller.

Sensor array optimization techniques for exhaled breath analysis to discriminate diabetics using an electronic nose

  • Jeon, Jin-Young;Choi, Jang-Sik;Yu, Joon-Boo;Lee, Hae-Ryong;Jang, Byoung Kuk;Byun, Hyung-Gi
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.802-812
    • /
    • 2018
  • Disease discrimination using an electronic nose is achieved by measuring the presence of a specific gas contained in the exhaled breath of patients. Many studies have reported the presence of acetone in the breath of diabetic patients. These studies suggest that acetone can be used as a biomarker of diabetes, enabling diagnoses to be made by measuring acetone levels in exhaled breath. In this study, we perform a chemical sensor array optimization to improve the performance of an electronic nose system using Wilks' lambda, sensor selection based on a principal component (B4), and a stepwise elimination (SE) technique to detect the presence of acetone gas in human breath. By applying five different temperatures to four sensors fabricated from different synthetic materials, a total of 20 sensing combinations are created, and three sensing combinations are selected for the sensor array using optimization techniques. The measurements and analyses of the exhaled breath using the electronic nose system together with the optimized sensor array show that diabetic patients and control groups can be easily differentiated. The results are confirmed using principal component analysis (PCA).

ZigBee 센서 네트워크를 이용한 생체신호 전송 및 저장 시스템의 구현 (Implementation of Bio-Signals Transmission and Storage System Using ZigBee Sensor Network)

  • 김영준;이인성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.131-132
    • /
    • 2007
  • In this paper, we designed and implemented bio-signals transmission and storage system using wireless sensor network based on ZigBee. Wireless sensor network is organized with routing protocol based on tree structure. The data is transmitted to monitoring system based on SIP. ZigBee will be used as various combinations with other wireless network technologies for application purposes.

  • PDF

8체질 맥법 검증을 위한 요골동맥 파형 측정 센서 개발

  • 문성수;정용원;이중재;공준웅;이흥세;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.9-12
    • /
    • 2001
  • In oriental medicine, it is possible to classify each person into eight kinds of constitutions based on the eight constitutional medicine theory. We developed a piezoelectric 3-channel tactile sensor using PVDF (polyvinylidene fluoride) film for pulse detection of the radial artery. High frequency buffer (impulse buffer), amplifier, 60 Hz noise notch filter and low pass filter were integrated on three sheets of PCB board. The pulses of the radial artery at three points were checked using our system. Each constitution of the eight ones has different combinations of pulses.

  • PDF

입사광량의 조절과 이에 따른 비분산 적외선 알코올 센서의 온도 특성과 보정 (Temperature Compensation and Characteristics of Non-dispersive Infrared Alcohol Sensor According to the Intensity of Light)

  • 김진호;조희찬;이승환
    • 센서학회지
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2018
  • In this paper, we describe the thermal characteristics of the output voltages of ethanol gas sensor according to the amount of radiation incident on the infrared sensors located at each focal point of two elliptical waveguides. In order to verify the output characteristics of the gas sensor according to the amount of incident light on the infrared sensor, two combinations of sensor modules were fabricated. Hydrophobic thin film is deposited on one of the reflectors of sensor modules and one of the two infrared sensors was equipped with a hollow disk (10 Ø), and the temperature characteristics of the infrared sensor equipped with the hollow disk (10 Ø) and the infrared sensor without the disk were tested. The temperature was varied from 253 K to 333 K at 10 K intervals based on 298 K. The properties of ethanol gas sensor have been identified with respect to varying temperature for a range of ethanol concentration from 0 ppm to 500 ppm. In the case of an infrared sensor equipped with a hollow disk (10 Ø), the output voltage of the sensor decreased by 0.8 mV and 1 mV, respectively, as the temperature increased. Conversely, the output voltage of the diskless infrared sensor showed an average increase of 67 mV and 57 mV as the temperature increased. The ethanol concentrations estimated on the basis of results show an error of more than 10 % for less than 100 ppm concentration. However, if the ethanol concentration exceeds 100 ppm, the gas concentration can be estimated within the range of ${\pm}10%$.

Gas Diffusion Tube Dimension in Sensor-Controlled Fresh Produce Container System to Maintain the Desired Modified Atmosphere

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • 한국포장학회지
    • /
    • 제19권2호
    • /
    • pp.61-65
    • /
    • 2013
  • Modified atmosphere (MA) of reduced $O_2$ and elevated $CO_2$ concentrations has been used for keeping the quality of fresh produce and extending the shelf life. As a way to attain the beneficial MA package around the produce, a gas diffusion tube or perforation can be attached onto the container and controlled on real time in its opening/closing responding to $O_2$ and $CO_2$ concentrations measured by gas sensors. The timely-controlled opening of the gas diffusion tube can work in harmony with the produce respiration and help to create the desired MA. By use of the mathematical modeling, the effect of tube dimension on the controlled container atmosphere was figured out in this study. Spinach and king oyster mushroom were used as typical commodities for designing the model container system (0.35 and 0.9 kg in 13 L, respectively) because of their respiration characteristics and the optimal MA condition ($O_2$ 7~10%/$CO_2$ 5~10% for spinach; $O_2$ 2~5%/$CO_2$ 10~15% for mushroom). With a control logic for the gas composition to stay as close as possible to optimum MA window without invading injurious low $O_2$ and/or high $CO_2$ concentrations, the atmosphere of the sensor-controlled container could stay at its lower $O_2$ boundary or upper $CO_2$ limit under certain tube dimensional conditions. There were found to be the ranges of the tube diameter and length allowing the beneficial MA. The desired range of the tube dimension for spinach consisted of combinations of larger diameter and shorter length in the window of 0.3~2 cm diameter and 0.2~10 cm length. Similarly, that for king oyster mushroom was combinations of larger diameter and shorter length in the window of 0.9~2 cm diameter and 0.2~3 cm in length. Clear picture on generally affordable tube dimension range may be formulated by further study on a wide variety of commodity and pack conditions.

  • PDF

Short Review of 3D Printed Piezoelectric Sensors

  • Chang, Sang-Mi;Kang, Chong-Yun;Hur, Sunghoon
    • 센서학회지
    • /
    • 제31권5호
    • /
    • pp.279-285
    • /
    • 2022
  • Recently, 3D printing technology has gained increased attention in the manufacturing industry because it allows the manufacturing of complex but sophisticated structures as well as moderate production speed. Owing to advantages of 3D printers, such as flexible design, customization, rapid prototyping, and ease of access, can also be advantageous to sensor developments, 3D printing demands have increased in various active device fields, including sensor manufacturing. In particular, 3D printing technology is of significant interest in tactile sensor development where piezoelectric materials are typically embedded to acquire voltage signals from external stimuli. In regard with piezoelectricity, researchers have worked with various piezoelectric materials to achieve high piezoelectric response, but the structural approach is limited because ceramics have been regarded as challenging materials for complex design owing to their limited manufacturing methods. If appropriate piezoelectric materials and approaches to design are used, sensors can be fabricated with the improved piezoelectric response and high sensitivity that cannot be found in common bulk materials. In this study, various 3D printing technologies, material combinations, and applications of various piezoelectric sensors using the 3D printing method are reviewed.

Direct write 기술로 제작된 유연촉각센서와 동합금 단자의 접촉저항 (Contact Resistance between Flexible Tactile Sensor Fabricated by Direct Write and Copper Alloy Terminals)

  • 김진동;배용환;윤해룡;이인환;김호찬
    • 한국기계가공학회지
    • /
    • 제19권10호
    • /
    • pp.111-116
    • /
    • 2020
  • Flexible tactile sensors, which are primarily used as grippers in robots, are mainly used to handle highly elastic or highly flexible objects. That is, flexible grippers are used when an object cannot be sufficiently controlled by applying a specific output force or taking a specific grabbing action. This is because a flexible tactile sensor needs to measure the pressure applied directly to held objects while deforming according to the shape of the object to be handled. CNT-based sensors used to be made from a highly flexible polymer to give flexibility and it is known that the sensors are greatly affected by the contact resistance of the terminal that connects the sensor to an electrical circuit; therefore, this paper clarifies the contact resistance of MWCNTs-based flexible tactile sensors and terminals. The effects of main and plating materials for terminals are investigated and the combinations of main and plating materials that exhibit contact resistance are measured in a typical industrial environment.

무선 센서 네트워크를 위한 준동형 암호체계 기반의 안전한 데이터 병합 기법 (Homomorphic Cryptoschemes based Secure Data Aggregation for Wireless Sensor Networks)

  • 뽀노마르추크율리아;남영진;서대화
    • 한국정보과학회논문지:정보통신
    • /
    • 제36권2호
    • /
    • pp.108-117
    • /
    • 2009
  • 데이터 병합은 무선 센서 네트워크 상에서 정보 전송시 소요되는 에너지를 줄이기 위해 잘 알려진 기법 중에 하나이다. 무선 센서 네트워크가 신뢰할 수 없고, 심지어 위험 환경에 노출되고 있으나, 기존 데이터 병합 기법은 센서 노드와 베이스 스테이션 종단간 데이터 프라이버시(데이터 기밀성 및 무결성)를 제공하지 못하는 문제점을 갖고 있다. 최근 들어 연구되고 있는 데이터 동상 암호체계 기법이 상기 위험 환경에서 종단간 프라이버시를 제공하기 위한 한 방법이 될 수 있다. 본 논문에서는 데이터 병합시 데이터 기밀성과 무결성을 보장하기 위하여 기존 동상 암호체계 기법 및 타기법 분석을 통하여 가능한 조합을 제시하고 CPU 부하 및 통신비용 측면에서 그 성능을 평가한다.

가변 파장형 적외선 가스 센서에 의한 생체표지자 분석 (Analysis of biomarkers with tunable infrared gas sensors)

  • 이승환
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.314-319
    • /
    • 2021
  • In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.