Expandable Cage for Cervical Spine Reconstruction

  • Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.435-441
    • /
    • 2005
  • Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.

스마트 헬스케어 시스템의 보안성 품질평가 방법에 대한 연구 (Study on the Methods of Security and Quality Evaluation of smart Healthcare System)

  • 양효식
    • 디지털융복합연구
    • /
    • 제15권11호
    • /
    • pp.251-259
    • /
    • 2017
  • 최근 헬스케어 산업이 사물인터넷(Internet of Thing) 기술과 결합한 스마트 헬스케어 산업이 주목을 받고 있다. 스마트 헬스케어란 애플리케이션, 웨어러블 기기, 플랫폼 등 정보통신 기술은 기반으로 한 건강관리 및 의료 서비스를 말한다. 스마트 헬스케어 산업은 차세대 산업분야인 6T 중 가장 활발한 IT(Information Technology)와 BT(Bio Technology)간의 결합으로 차세대 스마트 헬스케어 기기들이 늘어나고 있다. 다양한 스마트 헬스케어 기기들이 나타남에 따라 스마트 헬스케어 시스템이 다른 유기적 연동 여부와 보안성 품질 여부가 중요한 평가요소가 되고 있다. 본 논문에서는 이를 위해 스마트 헬스케어 시스템의 특성 및 서비스 유형을 조사하고 스마트 헬스케어 시스템의 기술 및 산업 동향을 분석하였다. 이를 바탕으로 스마트 헬스케어 시스템 평가 요구사항을 도출하여 스마트 헬스케어 시스템의 보안성 평가방법과 품질평가기준을 개발하고자 한다. 이는 스마트 헬스케어 시스템의 품질 향상 및 신뢰도 높은 제품 개발을 유도 할 수 있으며, 기술보호 장벽에 대처 할 수 있는 핵심기술로 기대된다.

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

천식치료의 최신지견 (Update in asthma management)

  • 이혜란
    • Clinical and Experimental Pediatrics
    • /
    • 제49권6호
    • /
    • pp.581-588
    • /
    • 2006
  • Asthma is a chronic inflammation of the airway associated with increased bronchial hyperresponsiveness that leads to recurrent episodes of cough, wheezing, breathless, chest tightness. According the recent studies, repeated airway inflammation leads to structural changes so called 'airway remodeling' and associated with decreased pulmonary function. Airway remodeling begins form the early stage of asthma and the early diagnosis and management is very important to prevent airway remodeling. Medication for asthma can be classified into acute symptom reliever and chronic controller. Short acting beta2 agonist is a well-known reliever that reduced asthma symptoms within minutes. Controllers should be taken daily as a long-term basis to control airway inflammation. Inhaled corticosteroid(ICS) is the most effective controller in current use. However, in some patients ICS monotherapy is not sufficient to control asthma. In those cases, other medications such as long acting beta2 agonist, leukotriene modifier or sustained-release theophylline should be added to ICS, which called Add-on-Therapy. Combination inhaler devices are easy to use. Oral leukotriene modifier has a good compliance especially in children. Finally, as asthma is a chronic disease, the development of on-going partnership among health care professionals, the patients, and the patients' family is necessary for the effective management of asthma.

항균 코팅제 (Antimicrobial Coating Agent)

  • 고종성
    • 한국응용과학기술학회지
    • /
    • 제30권1호
    • /
    • pp.96-115
    • /
    • 2013
  • 본 연구는 항균성 코팅제의 개념과 동향파악으로 항균성 코팅제의 연구개발의 방향을 설정하는데 도움을 주기 위한 것이다. 항균제는 미생물을 제거하거나 성장을 저지하는데 사용되는 화합물이며 항균 코팅제에 함유되는 항균제용 재료는 무기물, 금속, 저분자 유기물, 천연유기물, 고분자가 있다. 항균코팅제는 생활용품, 병원용품, 산업용품, 전자제품, 의류, 건축 내장재 등의 표면의 항균성 부여에 쓰인다. 기존 항생제는 세균의 세포벽을 손상하지 않고 미생물을 침투하나 항균성 고분자는 세포막을 파괴하므로 항생제의 내성을 방지할 수 있다. 대부분의 고분자 항균제는 양이온 고분자에 초점을 맞추고 있다. 항균제의 분자설계와 코팅제 배합의 합리화로 항균제의 선택성, 내구성, 독성 문제가 개선될 것이다.

비선형 반복 패턴과 스펙트럼 분석을 이용한 집중-비집중 분류기의 성능 평가 (Performance Evaluation of Attention-inattetion Classifiers using Non-linear Recurrence Pattern and Spectrum Analysis)

  • 이지은;유선국;이병채
    • 감성과학
    • /
    • 제16권3호
    • /
    • pp.409-416
    • /
    • 2013
  • 집중은 관련된 사건을 선택적으로 주의하고, 관련 없는 사건을 무시하는 인간의 중요한 인지 기능중의 하나이다. 인간의 집중 능력을 관리 이용하는 컴퓨터 기반 장치에 있어서 집중과 비집중 상태를 구분하는 것은 필수적으로 요구되는 조건이다. 본 논문에서는, 뇌파신호로부터 분류기의 입력으로 사용되는 특징을 효율적으로 추출하기 위하여 비선형 반복 패턴 분석기법과 스펙트럼 분석 기법을 새로이 결합하였고(13개 특징 추출), 서포트벡터머신, 역전파 알고리즘, 선형분리, 로지스틱 회귀 분류 기반 분류기들을 포함하는 집중-비집중 분류기들의 성능을 분석하였다. 그중에서 81 %의 정확도를 보이는 서포트벡터머신 분류기가 가장 좋은 성능을 보였다. 또한 스펙트럼 분석으로 추출한 특징만을 사용하였을 경우(76 % 정확도)가 비선형 분석 방법으로 추출한 특징만을 사용했을 경우(67 % 정확도)보다 좀 더 우수한 성능을 보였다. 비선형-스펙트럼 분석법을 복합 적용한 서포트벡터머신 분류기가 추후 집중 관련 장비 설계에 있어서 효율적으로 적용될 수 있을 것이다.

  • PDF

ICT융합 헬스케어 서비스 현황 및 발전전략 (ICT Convergence Healthcare Services Status and Future Strategies)

  • 이태규
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제7권10호
    • /
    • pp.865-878
    • /
    • 2017
  • 인간의 건강한 삶을 실현하기 위하여, 정신적, 육체적, 환경적 요인이 지속적이고 안정적으로 관리되어야한다. 인간건강을 안정적이고 효율적으로 관리하기 위해서 21세기 보건의료분야는 ICT기술과 지속적 상호작용 및 융합이 필수적으로 요구되어왔다. 이러한 시대적 요구는 이종(heterogeneous)기술의 결합으로 융합(fusion)기술을 창출했고, 의료기술과 ICT기술의 융합을 통해서 개인맞춤형 치료환경이 조성되며, 다양한 웨어러블 디바이스 개발로 ICT융합 모바일 건강의료 서비스가 발전되고 있다. 이러한 이종기술의 결합은 ICT융합 헬스케어시스템의 복잡도(complexity)를 기하급수적으로 상승시켜서, 다양한 기술적, 제도적, 환경적, 문화적 이슈와 문제들을 발생시키고 있다. 본 연구는 ICT 헬스케어 기술에 대해 과거부터 현재까지 이어지는 발전현황을 조명하고, 주요한 국내외 헬스케어 기술 및 정책 이슈들을 발굴하고, 최종적으로 이러한 과제들을 해결하기 위한 헬스케어 로드맵과 향후 발전방향을 제안한다.

한약을 사용하는 아시아권 국가의 유해사례 보고 양식에 관한 비교 연구 (Comparison about adverse drug reaction report forms among Asian's countries using herbal medicine)

  • 선승호;이은경;장보형;박선주;고호연;전찬용;고성규
    • 대한예방한의학회지
    • /
    • 제19권3호
    • /
    • pp.91-102
    • /
    • 2015
  • Objective : The purpose of this study is to find out the possibility of application to herbal medicine's report form for adverse drug reaction (ADR) by reviewing and analyzing Asian countries's ADR report forms. Method : We investigated, compared, and analyzed ADR report forms (ADR-RF) of Asian countries's ADR institutions (ACAI), such as, Korea institute of drug safety & risk management and Dongguk university Ilsan oriental hospital (DUIOH) in Korea, national center for ADR monintoring (NCAM) in China, pharmaceuticals and medical devices agency (PMDA) in Japan, Ministry of Health and Welfare (MOHW) in Taiwan, and drug office, department of health, the government of the Hong Kong special administrative region (GHKSAR) in Hong Kong. Results : ADR-RF for ACAI included common contents, such as, patients information (name(initial), gender, age, weight), adverse event (AE)'s report information (Recognition and report for AE occurrence, first or follow up report, Severe AE), the detailed information of AE (the title of AE, onset & closing date of AE symptoms, the progress & results detailed test of AE), the information of AE's medicine (the types of medicine, product name, ingredient name, suspected or combination drug, single dose & frequency, dosage form, administration route, dealing for AE-suspected medicine), and AE reporter's information (reporter's information, institution's information). Taiwan had ADR-RF and the department exclusively for herbal medicine (HM), but others (except DUIOH) had not only no ADR report form but also contents for HM. Conclusion : ADR-RF for HM have to include the common contents of ACAI at least, as well as HM information related to ADR, such as the title, composition and types of HM, history related to HM's ADR, and the contents of drug-induced liver injury and so on. In addition, the main department of government for HM's ADR will be needed.

디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가 (Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System)

  • 김창수;강세식;고성진
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.329-335
    • /
    • 2010
  • 디지털 방사선시스템에서의 의료영상 획득의 방법은 X선을 조사하고, 반도체 디텍터(Detector)를 이용하여 직접 및 간접으로 변환하여 기존 업체마다 여러 가지 알고리즘을 적용하여 적절한 이미지 프로세싱을 거쳐서 임상의 적정한 영상을 획득한다. 방사선과에서 적절한 의료 영상 형성을 위하여 적용하는 이미지 프로세싱 파라미터(Image Processing Parameters)는 Edge, Frequency, Contrast, Latitude, LUT, Noise 등의 영상 증강의 과정은 기술력 및 업체 알고리즘에 따라 다르게 적용되고 있다. 따라서 본 논문에서는 디지털 방사선 환경에서의 최종의 임상 영상을 위한 이미지 증강의 파라미터들의 적정 세팅 값의 기준을 제시하고자 한다. 그리고 각 병원들의 의료 영상을 바탕으로 이미지 프로세싱 파라미터들을 변화하여 각 파라미터들의 세부적인 기준 세팅값을 연구하며, 실제적인 파라미터 변화에 대한 적합한 의료 영상을 디지털방사선시스템의 영상 평가 방법을 도식화하여 결과를 제시하고, 향후 임상에서 적응 및 활용 가능한 객관적인 영상 파라미터에 대한 특성 평가의 응용을 정립하고자 한다. 또한 다양한 표본 병원의 디지털 방사선 환경에서 적정 파라미터 값들을 조사하여 임상에서 영상의 화질에 미치는 영향으로 특성 평가의 객관적인 기준의 변조전달함수(MTF)의 공간해상력을 제시하고 한다.