• Title/Summary/Keyword: Combination Cam

Search Result 62, Processing Time 0.029 seconds

Review of Safety for CAM System in Mold Structure Manching (금형 구조부 가공을 위한 CAM 시스템 안정성 조사)

  • Kim, Hyung-Man;Kim, Jong-Gurl
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.239-254
    • /
    • 2006
  • In mold structure machining, tool interference is a phenomenon which results from a collision between a blade of tool and a workpiece. Also tool collision is a phenomenon which results from a collision of holder with the object to be machined. These phenomena not only cause damages to mold and tool but also increase machining time and cost. To detect a collision of a tool to mold structure, first of all, the mold structure and a tool must be defined with famous geometric models such CSG, B-rep, and Voxel. A tool is defined as a combination of the blade, the shank, and the holder. This thesis reviews various collision detection algorithms using z-map and computer 3D graphic collision detection algorithms for the tool in machining a mold structure.

  • PDF

A Study on the Evidence-Based Herbal Medicine

  • Park, Jin-Han;Cho, Young-Mook;Choi, Sun-Kyung;Kim, Na-Hyun;Lee, Ki-Taeg;Hong, Seung-Heon
    • Journal of Evidence-Based Herbal Medicine
    • /
    • v.3 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • The use of complementary and alternative medicine (CAM) is currently widespread and appears to be growing. As an increasing proportion of the population turns to CAM therapies, whether singly or in combination with allopathic medicine, the need for quality research in this area is reinforced. Much of this research consists of clinical studies aim ed primarily at clinicians, yet challenges arising from poor methodological quality will occur w hen interpreting study findings and their implications. For clinicians to be effective consumers of the scientific literature, familiarization with the principles of evidence based medicine (EBM) is essential. The goal of this review is to introduce clinicians to the concept of critical appraisal of clinical studies and foster critical thinking when reading research articles in order to best evaluate and incorporate study findings into their daily practice.

  • PDF

Development of Cam Die for Processing four Lateral Switch Box (스위치 박스 4측면 가공용 캠금형 개발)

  • 김세환
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.79-82
    • /
    • 2003
  • 스위치 박스는 건축물의 전선관용으로 사용되는 금속제 박스이다. 이 박스를 제조할 때는 제 1차 프레스에서 성형을 하고, 제 2차~5차 프레스로 박스의 4측면 가공을 하게 되므로 프레스 4대, 금형 4벌, 작업자 4명을 필요로 한다. 이 때문에 기계 사용료와 금형비, 인건비 둥 제조원가의 상승 요인이 되고 있으며 특히 프레스의 굉음과 진동 및 안전사고의 위험성 등으로 작업자들이 직무를 기피하고 있다. 이러한 현상을 해소하기 위하여 금형 4벌에 의한 가공을 1벌의 금형에 통합시킨 캠금형 개발과 자동이송장치를 개발하였다. 그 결과, 프레스 1대와 금형 1벌로 무인화 작업을 할 수 있게 되어 직무기피요인을 해소하게 되고 제조원가 절감효과를 얻게 되었다

  • PDF

Oral rehabilitation that transit from optimized provisional through continuous re-evaluation to definitive prosthesis using CAD/CAM system: A case report (지속적인 재평가를 통해 최적화된 임시 보철을 최종 보철로 이행한 전악 CAD/CAM 고정성 수복 증례)

  • Lee, Suji;Woo, Yi-Hyung;Pae, Ahran;Noh, Kwantae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.444-450
    • /
    • 2017
  • Prosthetic decision-making is complex because of various factors, and involves a combination of the individual dentist's interpretation of the objective clinical data and his or her interaction with the patient. Increasing therapeutic options and emerging outcome data demand the constant re-evaluation of our decision-making process. In this case, fixed prosthetic restorations were selected as a treatment method to reconstruct the occlusal plane of a patient with disharmonious occlusal plane. And the occlusal plane was re-established by establishing a treatment plan through diagnostic wax-up. Provisional restorations obtained by continuous re-evaluation for a sufficient period of time was replicated to definitive restorations using CAD/CAM technology. The results were satisfactory when they were observed through clinical follow-up for 3 months after the end of treatment.

Entity management technology for automatic design in standard machine element (표준 기계부품의 자동설계를 위한 Entity 운용 기술)

  • 송재호;반갑수;이석희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.707-712
    • /
    • 1991
  • In machining a part in CAD/CAM system, it is required that the drawing information should be automatically generated, modified, deleted, and thus be used as an general information throughout the entire manufacturing process. This research addresses basic entities(point, line, circle, arc) for design feature and combination of this features, based on GT concepts, with minimum user's manual input. This paper deals with the generalization of operating system which can cover the s parts which appears in mechanical part handbook and the basic constitutional part of sold base. The system developed shows a strong application impact on automatic process planning system of medium - size injection sold companies.

  • PDF

Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

  • Rodiger, Matthias;Rinke, Sven;Ehret-Kleinau, Fenja;Pohlmeyer, Franziska;Lange, Katharina;Burgers, Ralf;Gersdorff, Nikolaus
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.233-240
    • /
    • 2014
  • PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

Incremental Sheet Forming of Complex Geometry Shape and Its Optimization Using FEM Analysis (복잡한 형상제품의 인크리멘탈 성형과 FEM을 이용한 공정 최적화)

  • Nguyen, D.T.;Park, J.G.;Lee, H.J.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.207-212
    • /
    • 2009
  • In order to optimize the press formability of incremental sheet forming for complex shape (e.g human face), a combination of both CAM and FEM simulation, is implemented and evaluated from the histories of stress and strain value by means of finite element analysis. Here, the results, using ABAQUS/Explicit finite element code, are compared with fracture limit curve (FLC) in order to predict and optimize the press formability by changing parameters of tool radius and tool down-step according to the orthogonal array of Taguchi's method. Firstly, The CAM simulation is used to create cutter location data (CL data). This data are then calculated, modified and exported to the input file format required by ABAQUS through using MATLAB programming. The FEM results are implemented for negative incremental sheet forming and then investigate by experiment.

  • PDF

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.