• Title/Summary/Keyword: Column-switching

Search Result 67, Processing Time 0.031 seconds

Determination of fluoride in fluorite mine wastewater by ion chromatography with post-wash technique (후세척-이온크로마토그래피를 이용한 형석 광산 폐수 중 플루오라이드 정량)

  • Song, Kyung-Sun;Eum, Chul-Hun;Kim, Sang-Yeon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.383-388
    • /
    • 2006
  • Simple post-wash method by ion chromatography (IC) was established for the rapid and precise determination of fluoride ion in wastewater from mine in fluorite mineralized area. High sulfate in sample was retained in a pre-column and less strongly held fluoride ion was transferred to the principal separation system using modified conventional IC with switching technique. An analytical column with high capacity (AS 9 HC) was used as a pre-column to retain the amount of high sulfate. A guard column (AG 14) as a separation column was used to increase the response of fluoride and reduce the system pressure. According to the recovery of fluoride ion with one detector and the observation of sulfate peak with another conductivity detector, the optimum switching time of 10-port chromatographic injector was 4.3 min. The limit of detection (S/N = 3) of fluoride in synthetic solution containing $500mg\;L^{-1}$ sulfate was $2.4{\mu}g/L$, with $25{\mu}L$ sample volume.

Determination of Vitamin B12 (Cyanocobalamin) in Fortified Foods by HPLC

  • Park, Youn-Ju;Jang, Jae-Hee;Park, Hye-Kyung;Koo, Yong-Eui;Hwang, In-Kyeong;Kim, Dai-Byung
    • Preventive Nutrition and Food Science
    • /
    • v.8 no.4
    • /
    • pp.301-305
    • /
    • 2003
  • This study was conducted to develop an HPLC method for determining vitamin B$_{12}$ in fortified foods which has typically been determined by microbiological assays according to AOAC and Korean Food Code approved methods. Vitamin B$_{12}$ (cyanocobalamin) was determined by reversed-phase HPLC with a triple column and UV/VIS dectector (550 nm) using the column switching technique after extraction with 5 mM potassium phosphate solution by sonication without a clean-up procedure. The recovery of spiked samples and limit of detection (LOD) by HPLC were 78.6 ∼107.5 % and 2 ppb ($\mu\textrm{g}$/kg), respectively. The LOD of the microbiological assay (MBA) was much lower than that of HPLC. The concentrations of vitamin B$_{12}$ analyzed in all tested samples (n=12) confirmed compliance with declared label claims. The range of recovery ratio by the HPLC method when compared to the microbiological assay was 76.2 ∼140.0 %. There was not significant difference between the HPLC and MBA methods (p < 0.01) with r=0.9791 and linear regression y=0.9923x-0.04. The HPLC method for determining vitamin B$_{12}$ using the column-switching technique appears to be suitable for determining vitamin B$_{12}$ concentrations above 1 $\mu\textrm{g}$/100 g in fortified foods.ied foods.

TORANOMON HILLS - Super High-Rise Building on Urban Highway -

  • Hitomi, Yasuyoshi;Takahashi, Hiroshi;Karasaki, Hidenori
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • TORANOMON HILLS is the main building of a large-scale re-development project located in the center of Tokyo. This high-rise building has a height of 247 m and 52 floors above ground, 5 floors below ground, and $62m{\times}80m$ in plan. It is used as hotel, residential facilities, offices, shops and conference facilities. The super structure is mainly a rigid steel frame with response-control devices, using concrete-filled steel tube columns. The underground section is a mixed structure composed of steel, steel-reinforced concrete and reinforced concrete framings. The piled-raft foundation type is used. The remarkable feature of this high-rise building is that the motorway runs through the basements of the building, which makes it stand just above the motorway. This condition is an important factor of the building design. The plan shape is designed to fit along the curve of the motorway. Special columns at the corners are required to avoid placing columns in the motorway. This special column is a single inclined column in the lower floors that branches into two columns in the mid-floors to suit the column location in the upper floors. The cast steel joint is used for the branching point of each special column to securely transfer the stress.

Determination of Vitamin B12 and Biotin in Foods for Special Dietary Uses with Immunoaffinity Column (면역친화성 컬럼을 이용한 특수용도식품 중 비타민B12와 비오틴 분석 연구)

  • Oh, Bo-Young;Ye, Min-Ji;Hu, Soo-Jung;Lee, Hye-Young;Bang, Soo-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.252-260
    • /
    • 2020
  • This study was conducted to improve the standard method for vitamin B12 and biotin contained in foods for special dietary uses to ensure the specificity of the complex matrix properties of foods. For the food code, the test method was improved to determine vitamin B12 and biotin by high-performance liquid chromatography (HPLC)-UV using column-switching after concentration using immunoaffinity column. The immunoaffinity columns contain a gel suspension of monoclonal antibody specific to the vitamin of interest so that it can be used to concentrate the vitamin B12 and biotin and remove interferences from the food extracts. Moreover, validation of advanced new methods was carried out to support the suitability of the proposed analytical procedure (specificity, linearity, detection limits (LOD), quantitative limits (LOQ), accuracy, and precision). The improved analytical method is being used to monitor relevant food items on sale. The results of this study showed that the new analytical method is suitable and appropriate for managing food intended for special dietary uses.

DC Arc Extinction Using External Magnetic Field in Switching Device

  • Cho Hyun-Kil;Lee Eun-Woong;Jeong Jong-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.306-311
    • /
    • 2005
  • In this paper, the electromagnetic force acting in the arc column of 3 different extinction units is compared with using the FEM (Finite Element Method) and the arc velocity is calculated by the drag force of the fluid mechanics. The experiment for breaking the arc current was performed in each model at 100 volts in order to measure the arcing time. The outcome was compared with the computing value. As a result, this paper proposes that the divided U-shaped grid is able to shorten arcing time and improve the electric performance. It also suggests a methodology for comparing and analyzing the result obtained by simulation and experiment.

Multidimensional Gas Chromatography-A Powerful Tool for the Analysis of Multicomponent Mixtures

  • Kim, Kyoung-Su
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.127-133
    • /
    • 1996
  • The development of high resolution capillary columns and a large variety of different detectors led to a strong position of gas chromatography in instrumental analysis. Every effort has been made to solve sophisticated separation problems by column switching. Nowadays, several systems are commercially available for this purpose. The principle and the capabilities of multidimensional gas chromatography(MDGC) are illustrated by different applications in the field of modern flavor and essential oil research.

  • PDF

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

Fast and Accurate Determination of Algal Toxins in Water using Online Preconcentration and UPLC-Orbitrap Mass Spectrometry (온라인 시료주입과 UPLC-Orbitrap 질량분석법을 이용한 수질 조류독소의 고속분석방법 개발 및 환경시료적용)

  • Jang, Je-Heon;Kim, Yun-Seok;Choi, Jae-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.843-850
    • /
    • 2012
  • Due to the fast response to algae bloom issue in drinking water treatment plant, very fast determination methodology for algal toxin is required. In this study, column switching technique based online preconcentration method was combined with high resolution full scan mass spectrometer to save sample preparation time and to obtain fast and accurate result. After parameter optimization of online preconcentration, 1mL filtered sample was directly injected to trap column with switching valve system. Next, target toxins are eluted by 98% acetonitrile and analysed with 150 - 1,100 amu scan range at 50,000 resolving power. Method detection limit (MDL) for microcystin-LR, the most toxic isomer, was 0.1 ng/mL and others such as microcystin-YR, microcystin-RR and nodularin were 0.08, 0.03 and 0.04 ng/mL, respectively. This is the best improved sensitivities with 1mL volume in the literature. Furthermore, due to the use of ultra pressure HPLC (UPLC), the whole method run was completed in 4 min. Real sample applications for 173 sample including 55 surface water and 118 treatment plant samples for raw and treated water could be done within 16 hours. In our calculation, this methodology is roughly 80% faster than the previous manual solid-phase extraction with LC-MS/MS method.

Polynomial Time Algorithm for Multi-Beam SS/TDMA Satellite Communications Scheduling Problem with Frequency-Hopping Ground Stations

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.7
    • /
    • pp.33-40
    • /
    • 2015
  • The time slot assignment problem (TSAP) or Satellite Communications scheduling problem (SCSP) for a satellite performs $n{\times}n$ ground station data traffic switching has been known NP-hard problem. This paper suggests $O(n^2)$ time complexity algorithm for TSAP of a satellite that performs $n^2{\times}n^2$ ground station data traffic switching. This problem is more difficult than $n{\times}n$ TSAP as NP-hard problem. Firstly, we compute the average traffic for n-transponder's basic coverage zone and applies ground station exchange method that swap the ground stations until all of the transponders have a average value as possible. Nextly, we transform the D matrix to $D_{LB}$ traffic matrix that sum of rows and columns all of transponders have LB. Finally, we select the maximum traffic of row and column in $D_{LB}$, then decide the duration of kth switch mode to minimum traffic from selected values. The proposed algorithm can be get the optimal solution for experimental data.