• 제목/요약/키워드: Column failure mode

검색결과 232건 처리시간 0.03초

편심을 가진 1/12 축소 RC 주상복합구조물의 진동대실험 (Shaking Table Tests of 1/12-Scale RC Bearing-Wall System with Bottom Piloti Stories Having Eccentric Shear-Wall)

  • 이한선;고동우;권기혁;김병현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.185-190
    • /
    • 2001
  • The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1:12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames with infilled shear wall have two different layouts of the plan : The one has symmetric plan and the other has unsymmetric plan. Then, this model was subjected to a series of earthquake excitations. The test results show that the layout of shear wall has the negligible effect on the natural period and the base shear coefficient, but great effect on the failure mode of beam-column joint at flexible side frame.

  • PDF

Experimental study on reinforced concrete filled circular steel tubular columns

  • Hua, Wei;Wang, Hai-Jun;Hasegawa, Akira
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.517-533
    • /
    • 2014
  • Experimental results of 39 specimens including concrete columns, RC columns, hollow steel tube columns, concrete filled steel tubular (CFT) columns, and reinforced concrete filled steel tubular (RCFT) columns are presented. Based on the experimental results, the load-carrying capacity, confined effect, ductility, and failure mode of test columns are investigated. The effects of the main factors such as width-thickness ratio (the ratio of external diameter and wall thickness for steel tubes), concrete strength, steel tube with or without rib, and arrangement of reinforcing bars on the mechanical characteristics of columns are discussed as well. The differences between CFT and RCFT are compared. As a result, it is thought that strength, rigidity and ductility of RCFT are improved; especially strength and ductility are improved after the peak of load-displacement curve.

Strengthening of preloaded RC columns by post compressed plates-a review

  • Wang, L.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • 제65권4호
    • /
    • pp.477-490
    • /
    • 2018
  • Reinforced concrete (RC) columns, as the primary load-bearing structural components in buildings, may need to be strengthened due to material deteriorations, changes in usage, new building codes or new design requirements. The use of post compressed plates (PCP) to strengthen existing RC columns has been proven experimentally and practically to be effective in solving stress-lagging effects between the original column and the new strengthening jacket caused by the pre-existing loads. This paper presents a comprehensive summary and review of PCP strengthening techniques to strengthen preloaded RC columns. The failure mode, deformability, and ductility of the strengthened RC columns are reviewed.

Numerical investigation on punching shear of RC slabs exposed to fire

  • Sadaghian, Hamed;Farzam, Masood
    • Computers and Concrete
    • /
    • 제23권3호
    • /
    • pp.217-233
    • /
    • 2019
  • This paper describes the numerical modelling of an interior slab-column connection to investigate the punching shear resistance of reinforced concrete (RC) slabs under fire conditions. Parameters of the study were the fire direction, flexural reinforcement ratio, load levels, shear reinforcement and compressive strength of concrete. Moreover, the efficiency of the insulating material, gypsum, in reducing the heat transferred to the slab was assessed. Validation studies were conducted comparing the simulation results to experiments from the literature and common codes of practice. Temperature dependencies of both concrete and reinforcing steel bars were considered in thermo-mechanical analyses. Results showed that there is a slight difference in temperature endurance of various models with respect to concrete with different compressive strengths. It was also concluded that compared to a slab without gypsum, 10-mm and 20-mm thick gypsum reduce the maximum heat transferred to the slab by 45.8% and 70%, respectively. Finally, it was observed that increasing the flexural reinforcement ratio changes the failure mode from flexural punching to brittle punching in most cases.

Experimental and numeral investigation on self-compacting concrete column with CFRP-PVC spiral reinforcement

  • Chen, Zongping;Xu, Ruitian
    • Earthquakes and Structures
    • /
    • 제22권1호
    • /
    • pp.39-51
    • /
    • 2022
  • The axial compression behavior of nine self-compacting concrete columns confined with CFRP-PVC spirals was studied. Three parameters of spiral reinforcement spacing, spiral reinforcement diameter and height diameter ratio were studied. The test results show that the CFRP strip and PVC tube are destroyed first, and the spiral reinforcement and longitudinal reinforcement yield. The results show that with the increase of spiral reinforcement spacing, the peak bearing capacity decreases, but the ductility increases; with the increase of spiral reinforcement diameter, the peak bearing capacity increases, but has little effect on ductility, and the specimen with the ratio of height to diameter of 7.5 has the best mechanical properties. According to the reasonable constitutive relation of material, the finite element model of axial compression is established. Based on the verified finite element model, the stress mechanism is revealed. Finally, the composite constraint model and bearing capacity calculation method are proposed.

GFRP 래핑에 의한 겹침이음된 교각의 내진보강 (Seismic Retrofit of GFRP Wrapping on the Lap-spliced Bridge Piers)

  • 염광수;권태규;이영호;황윤국
    • 대한토목학회논문집
    • /
    • 제26권2A호
    • /
    • pp.311-318
    • /
    • 2006
  • GFRP를 이용하여 종방향 철근의 겹침이음이 존재하는 원형RC 교각의 내진보강 성능을 파악하기 위해 5개의 실물규모 실험체를 제작하여 실험하였다. 대상교각은 1979년에 완공된 후 현재 공용중인 비내진 원형 RC교각으로 겹침이음된 종방향 철근의 부착파괴에 의한 급작스런 파괴가 예상된다. GFRP 래핑(Wrapping)으로 보강된 교각들의 내진성능은 매우 향상되었다. 하지만, 예상한 휨파괴는 발생하지 않았고, 종방향 철근은 항복하지 않았다. 보강된 교각의 파괴양상은 겹침이음된 종방향 철근의 지연된 부착파괴로 판단된다. 제안된 GFRP 보강설계법을 실험적으로 검증하였다.

Modelling beam-to-column joints in seismic analysis of RC frames

  • Lima, Carmine;Martinelli, Enzo;Macorini, Lorenzo;Izzuddin, Bassam A.
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.119-133
    • /
    • 2017
  • Several theoretical and analytical formulations for the prediction of shear strength in reinforced concrete (RC) beam-to-column joints have been recently developed. Some of these predictive models are included in the most recent seismic codes and currently used in practical design. On the other hand, the influence of the stiffness and strength degradations in RC joints on the seismic performance of RC framed buildings has been only marginally studied, and it is generally neglected in practice-oriented seismic analysis. To investigate such influence, this paper proposes a numerical description for representing the cyclic response of RC exterior joints. This is then used in nonlinear numerical simulations of RC frames subjected to earthquake loading. According to the proposed strategy, RC joints are modelled using nonlinear rotational spring elements with strength and stiffness degradations and limited ductility under cyclic loading. The proposed joint model has been firstly calibrated against the results from experimental tests on 12 RC exterior joints. Subsequently, nonlinear static and dynamic analyses have been carried out on two-, three- and four-storey RC frames, which represent realistic existing structures designed according to old standards. The numerical results confirm that the global seismic response of the analysed RC frames is strongly affected by the hysteretic damage in the beam-to-column joints, which determines the failure mode of the frames. This highlights that neglecting the effects of joints damage may potentially lead to non-conservative seismic assessment of existing RC framed structures.

중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가 (Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building)

  • 하기주;신종학;허민행;홍건호;하재훈;남영식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.453-454
    • /
    • 2009
  • 본 연구에서는 중 고층 철근콘크리트 주상복합형 건축물에서 지진하중과 같은 반복하중이 작용할 때 단차형 내부 보-기둥 접합부의 거동 특성을 파악하기 위하여 단차 유무에 따른 내부 보-기둥 접합부 실험체를 대상으로 실험을 실시하여 다음과 같은 결론을 얻었다. 단차가 있는 내부 보-기둥 접합부 실험체는 단차가 없는 표준실험체(FJ-0D)와 비교하여 단차 수준(1.0D, 2.0D)이 증가함에 따라 수평내력과 에너지소산능력이 증가하였고 내부 보-기둥 접합부 영역을 중심으로 균열진전 상황이 상이하였다. 또한 에너지소산능력은 내부 보-기둥 접합부 단차가 높을수록 1.1${\sim}$1.35배 증가하였다.

  • PDF

유연도법 섬유요소모델에 의한 반복하중을 받는 철근콘크리트 교각의 연성능력 평가 (Evaluation of Ductility Capacity of Reinforced Concrete Bridge Columns Subject to Cyclic Loading Using Flexibility-Based Fiber Element Method)

  • 고현무;조근희;조호현
    • 한국지진공학회논문집
    • /
    • 제6권3호
    • /
    • pp.11-21
    • /
    • 2002
  • 유연도법 섬유요소모델을 통하여 반복하중을 받는 철근콘크리트 교각의 비탄성 이력 거동을 추적하고 직접적인 방법에 의해 변위연성도 평가를 수행하였다. 철근 콘크리트 교각의 극한상태까지의 비탄성 거동을 합리적으로 추적하기 위해 인장강성거동, 기둥-기초면의 불연속 변위 등을 고려하여 철근과 콘크리트의 평균응력-평균변형률 관계, 접촉면요소 등을 실험과 잘 일치하는 기존의 해석 모델을 수정, 적용하였다. 또한 수치해석시 간편하게 적용할 수 있는 직접적인 방법에 의하여 교각의 연성능력을 평가하였으며, 항복변위 및 극한변위의 산출에 영향을 미치는 적분점의 위치, 콘크리트 압쇄 후 강루 철근의 low-cycle fatigue에 의한 파단 시점 등에 대하여 유연도법 섬유요소모델에 적용할 수 있는 값들을 제시하였다. 해석에 의한 변위연성도는 10%이내의 오차를 보이므로, 적용한 해석기법 및 모델에 의한 항복변위 및 극한변위의 평가는 타당하다고 할 수 있다.

폴리스티렌 폼을 사용한 슬래브의 뚫림전단에 관한 실험적 연구 (An Experimental Study on the Punching Shear of Slab with Polystyrene Form)

  • 이환구;김승훈;강인석;이한승;이기장
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.213-216
    • /
    • 2008
  • 슬래브에 폴리스티렌을 이용한 경량폼을 적용할 경우, 슬래브 중량이 감소함에 따라 보다 경간이 증가하거나 슬래브 지지 부재 크기가 감소될 수 있다. 하지만 플랫플레이트 구조에서 경량폼을 사용한 슬래브는 기둥주위 위험단면에서의 뚫림전단성능이 저하될 수 있다. 그러나 이에 관한 내력산정을 위한 기준이 없으며, 기존 연구 또한 부족한 실정이다. 본 논문은 폴리스티렌 경량폼을 사용한 슬래브-기둥 접합부의 뚫림전단내력을 파악하기 위하여 실시한 뚫림전단 실험에 관한 것이다. 주요 변수는 기둥의 크기, 폴리스틸렌 폼의 배치형태, 전단보강 유무 등으로 총 4개 실험체를 계획하였다. 실험을 통하여 균열 및 파괴모드, 하중-변위곡선, 뚫림전단강도 등을 분석함으로써 경량폼을 사용한 슬래브의 뚫림전단 성능을 파악하였다.

  • PDF