• 제목/요약/키워드: Column extraction

검색결과 761건 처리시간 0.024초

한국산 도꼬마리 추출물의 항균효과 및 분리 정제

  • 김현수;신재욱
    • Microbiology and Biotechnology Letters
    • /
    • 제25권2호
    • /
    • pp.183-188
    • /
    • 1997
  • Antimicrobial activity of various extracts of Xanthium strumarium L. was tested against 25 strains of bacteria, yeast and fungus. The crude ethylacetate extract exhibited strong growth inhibition to the tested strains with the exception of partial Gram-negative bacteria. The property of antimicrobial compound was very stable under heat treatment at $120^{\circ}C$, but it was unstable in acid (pH 3.0) and alkali (pH 10.0) treatment. The antimicrobial compounds were purified by boiling water extraction, ethylacetate extraction, charcoal column chromatography, silica gel column chro- matography and reverse phase HPLC. The purified compound A and B were detected in a single peak (each above 98% purity) through the HPLC analysis. The compound A and B showed a strong growth inhibition against Gram-negative and positive bacteria in the agar diffusion method. When tested by the FDA method using the esterase, compound A mainly inhibited the growth of bacteria and compound B showed the growth inhibition of both bacteria and yeasts.

  • PDF

Formation of Metal Complex in a Poly(hydroxamic acid) Resin Bead

  • Lee, Taek-Seung;Jeon, Dong-Won;Kim, Jai-Kyeong;Hong, Sung-Il
    • Fibers and Polymers
    • /
    • 제2권1호
    • /
    • pp.135-139
    • /
    • 2001
  • Poly(hydroxamic acid) resin beads were prepared and complexed with various metal ions. We used IR spectroscopy to investigate the structure of metal complex. It proved that the products formed by introduction of metal ions gave stable and colored complex. It was found that the resin bead as synthesized would be a good column packing material for continuous extraction. Energy dispersive spectroscopy was use to study the distribution of metal ions in the resin matrix. It could be tentatively concluded that adsorption and diffusion of metal ions in the chelating resins mainly depended on the loading of the resin matrix which indicated interacting sites with metal ions.

  • PDF

Purification and Characterization of Antibiotics KG-1167A & KG-1167B Produced by Clostridium sp. (Clostridium sp.가 생산하는 항생물질 KG-1167A와 KG-1167B의 정제 및 특성)

  • 홍수형;류재호;하지홍;박용복
    • Microbiology and Biotechnology Letters
    • /
    • 제18권3호
    • /
    • pp.286-291
    • /
    • 1990
  • The antibiotics KG-1167A and KG-1167B were isolated from the fermentation broth of the bacterial strain KH-1167, identified as Cloetridium sp. The individual antibiotics, KG-1167A & KG-1167B were separated and purified by solvent extraction followed by silica gel column chromatography. These antibiotics showed antibacterial activities against broad spectrum of gram positive and gram negative bacteria. The physico-chemical properties and UV spectra suggest that they possess aromatic moiety in their structures.

  • PDF

석회석을 활용한 광미와 폐석의 Cd, Cu, Pb 및 Zn의 제거

  • Ji Han-Gu;Jeong Myeong-Chae;Jeong Mun-Yeong;Choi Yeon-Wang;Lee Mun-Hyeon;Lee Jae-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.20-23
    • /
    • 2005
  • The objective of this study is to examine a stabilized efficiency of heavy metals including Cd, Cu, Pb and Zn using slaked lime. Tailings from the Janggun Pb-Zn mine, the second Yeonhwa Pb-Zn mine, the Jisi Au-Ag mine and the Sangdong W mine were sampled and measured heavy metal concentrations contents using AAS as various extraction methods. During 156 hours, column test were undertaken to evaluate the possibility of stabilization by slaked lime. The result shows that $Ca(OH)_2$ has a good efficiency in heavy metal stabilization, especially at the Jisi mine with stabilized efficiencies of 97%(Cd), 99%(Cu), 86%(Pb) and 99%(Zn), respectively.

  • PDF

Purification and Identification of Squalene Synthase Inhibitor Isolated from Fermented Soybean Paste

  • Choi, Sung-Won;Kim, Dong-Seob;Hur, Nam-Youn;Park, Cheon-Seok;Baik, Moo-Yeol
    • Food Science and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.89-93
    • /
    • 2005
  • Squalene synthase (SQS) inhibitors were screened from various plants and food extracts. Effective SQS inhibitor was purified from fermented soybean paste using ethanol extraction, HP-20 column chromatography, ethyl acetate extraction, silica gel column chromatography, and crystallization. Through UV spectrometry, $^1H$ NMR, $^{13}C$ NMR, and mass spectrometry, SQS inhibitor was identified as daidzein with molecular mass of 254 and molecular formula of $C_{15}H_{10}O_4$. Daidzein showed $IC_{50}$ value of 50 nmol/L against SQS, confirming its potential as therapeutic agent for hypercholesterolemia.

The Simultaneous Analysis of Oxytetracycline, Chloramphenicol and Sulfamethoxazole in Pork by HPLC (HPLC를 이용한 돈육 중의 Oxytetracycline, Chloramphenicol 및 Sulfamethoxazole의 동시검출)

  • 조혜연;조진국;이치호
    • Food Science of Animal Resources
    • /
    • 제21권1호
    • /
    • pp.64-70
    • /
    • 2001
  • The extraction procedure and HPLC condition were modified to analyze the residues of oxytetracycline, sulfamethoxazole and chloramphenicol in pork, simultaneously. The antibacterial agents in pork were extracted with 0.02M EDTA-Mcilivine buffer:ethanol:acetonitrile (5:3:2). After the removal of fat with n-hexane, the extracts were evaporated and purified with Sep-pak $C_{18}$ cartridge column using 0.01M oxalic acid 0.1% (v/v) triethylamine (TEA) in acetonitrile. The peak of antibacterial agents was detected with $\mu$ Bondapak C18 column, UV detector (280nm) and 0.01M oxalic acid: methanol: acetonitrile (7.5:2.0:0.5). Detection limits for three antibacterial standards were 0.03 ppm. Calibration curves were linear between 0.03 and 2.0 ppm (R$^2$>0.999). When spiked the level of 1.0 ppm of oxytetracycline, sulfamethoxazole and chloramphenicol into meats, the recoveries from meats were 77.3%, 79.7% and 59.3%, respectively. These results showed that the modified extraction method provided good analytical resolution and the recoveries of the above antibacterial agents in meats.

  • PDF

A Synthesis of Optically Active cis and trans 2-(5-Hydroxypoperidin-2-yl)acetates

  • P.N. Reddy;한상수;정교현
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.617-618
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBs) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

Analytical Method for Dioxin and Organo-Chlorinated Compounds : (I) Pretreatment of Milk Samples for Dioxin Analysis

  • 양정수;김진영;최용욱;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.619-624
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBS) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

Analyses of phenolics in cigarette smoke by GC-MS with the multiple ion selction technique

  • Park, Jeen-Woo
    • Archives of Pharmacal Research
    • /
    • 제5권2호
    • /
    • pp.71-77
    • /
    • 1982
  • Improvements in the analytical methodology used in the gas chromatographic/mass spectral analysis of phenolic compounds from cigarette smoke are described. For the direct analysis of crude samples, pyridine extraction and the glass capillary column GC was used for the separation of phenolics as trimethylsilyl derivativatives. The separations of cigarette smoke on Carbowax 20M and SE-54 wall coated open tubular columns are given. Improved methodology for the routine quantitation of the identified components using the computer-controlled multiple ion selection technique of MS presented. Considerations pertaining to routine analyses of a multitude of complex smoke samples are also discussed.

  • PDF

Mass Balance on the Pulping Extracts of Maple Hardwood using High Performance Liquid Chromatography (HPLC 분석기를 이용한 펄프용 단풍나무의 펄핑 추출액에 관한 물질수지)

  • Um, Byung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권4호
    • /
    • pp.102-108
    • /
    • 2008
  • At the University of Maine, a hemicellulose pre-extraction technology is now being investigated to improve pulp yields, reduce the organic and inorganic load for liquor recovery, and create a feed stream for the generation of new biomaterials. It is important to understand the composition of unextracted wood, extracted wood, and pulping extracts in the design of an economically viable pilot-scale ethanol plant. For analysis of wood pulp composition, the total analytical mass balance closure was 100.6, 100.3, and 81.6% for unextracted chips, extracted chips, and pulping extracts from HPLC-H column analysis. Meanwhile, the total analytical mass balance from the HPLC-P column was 97.8, 86.3, and 80.7%, respectively. This slight variability between H- and P-column results for analytical mass balance may be within the experimental error of the measurement. The data generated by this analysis are important to further design work in commercializing this process.