• Title/Summary/Keyword: Collector well system

Search Result 56, Processing Time 0.023 seconds

Experimental Study on Thermal Performance of Palte-type Fresh Water Generator for applying Solar Energy Desalination System (태양에너지 해수담수화시스템에의 적용을 위한 판형 해수담수기의 열성능에 관한 실험적 연구)

  • Kim, Jeong-Bae;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.35-41
    • /
    • 2007
  • To demonstrate the desalination system, the demo-plant was scheduled to be installed. The system was planned to use solar thermal collector as heat source and PV as electricity source. For the design of the desalination demonstration system, firstly the solar thermal system would be well designed from the result between the supplied heat into the fresh water generator and the fresh water yield. The generator for demonstration system was chosen as the fresh water generator of the single stage and effect with plate-type heat exchanger using low pressure evaporation method. The test facility for the tests to reveal the relationship between the fresh water yield and the supplied heat flow rate was designed and manufactured. The maximum fresh water yield of two fresh water generators applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. Through the experiments, this study firstly showed detail operation characteristics of the generator and designed the solar thermal system for the demonstration system.

A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater (복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구)

  • Choi, Hwi-Ung;Rokhman, Fatkhur;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

DOMAIN DECOMPOSITION ALGORITHM AND ANALYTICAL SIMULATION OF COUPLED FLOW IN RESERVOIR / WELL SYSTEM

  • EWING, RICHARD;IBRAGIMOV, AKIF;LAZAROV, RAYCHO
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.5 no.2
    • /
    • pp.71-99
    • /
    • 2001
  • The model and analytical method for solving the problem of coupled fluid flow in the reservoir/well system is presented. The 3-D drainage area is composed of three connected media: the tubing, the annuli as a super conducting collector, and the reservoir itself. To couple these three types of fluid flows a non-overlapping Dirichlet-Neumann domain decomposition method is developed. The method allows us to apply an analytical hybrid simulator for accurate evaluation of the impact of main geometrical and hydrodynamic parameters of the 3-D system on the pressure drop along the horizontal well and its production index.

  • PDF

Utilizing OpenFlow and sFlow to Detect and Mitigate SYN Flooding Attack

  • Nugraha, Muhammad;Paramita, Isyana;Musa, Ardiansyah;Choi, Deokjai;Cho, Buseung
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.8
    • /
    • pp.988-994
    • /
    • 2014
  • Software Defined Network (SDN) is a new technology in computer network area which enables user to centralize control plane. The security issue is important in computer network to protect system from attackers. SYN flooding attack is one of Distributed Denial of Service attack methods which are popular to degrade availability of targeted service on Internet. There are many methods to protect system from attackers, i.e. firewall and IDS. Even though firewall is designed to protect network system, but it cannot mitigate DDoS attack well because it is not designed to do so. To improve performance of DDOS mitigation we utilize another mechanism by using SDN technology such as OpenFlow and sFlow. The methodology of sFlow to detect attacker is by capturing and sum cumulative traffic from each agent to send to sFlow collector to analyze. When sFlow collector detect some traffics as attacker, OpenFlow controller will modify the rule in OpenFlow table to mitigate attacks by blocking attack traffic. Hence, by combining sum cumulative traffic use sFlow and blocking traffic use OpenFlow we can detect and mitigate SYN flooding attack quickly and cheaply.

Analysis on the Effect of Thermal Performance with Various Load Patterns for Solar Hot Water Heating System

  • Kim, Byoung-Gi;Jang, Hwan-Young;Chung, Kyung-Taek;Suh, Jeong-Se
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.108-113
    • /
    • 2007
  • The performance of a solar water heater incorporating evacuated tubes was evaluated using a transient simulation program, TRNSYS. Simulations were performed for $60^{\circ}C$ of hot water load temperature and for 280 liter of daily hot water volumes and three 400 liter of storage tank volumes. Three patterns of daily hot water consumption profile were used in the present study (morning, lunch and evening). The results show that the increase in solar fraction depends on the load profile, as well as the collector efficiency coefficient. Hot water draw profile has a large effect on the performance of the SDHWS, the morning load profile has the highest solar fraction. The annual solar fraction of the system, at the weather conditions of Jinju is approximately 84% at lunch load pattern, the 280 kg of load volume, 400 kg of tank volume and the $60^{\circ}C$ of load temperature.

Analysis of Operating Characteristics of Large-scale Solar Thermal System Using Two Types of Collectors (두 종류 태양열 집열기를 이용하는 대규모 태양열 시스템의 동작특성 분석)

  • Lee, Dong-Won;Heo, Jae-Heok;Kim, Min-Hwi
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.67-75
    • /
    • 2017
  • We have investigated the operating characteristics of $1,600m^2$ large-scale solar thermal system installed in an eco-friendly energy town in Chungbuk Innovation City. The operation criteria of the collecting pump and storage pump were different from the existing standard, and it was confirmed that each pump works well according to the changed criteria. Based on the data of the representative day, the daily collecting heat (efficiency) and the production (storing) heat (efficiency) were estimated. It was confirmed that the daily collecting heat (efficiency) of the flat plate type was higher than that of the evacuated tube type, but the useful heat production was more in evacuated tube type collector.

Current Status and Application of Agricultural Subsurface Dams in Korea (국내 농업용 지하댐의 현황 및 활용 사례)

  • Yong, Hwan-Ho;Song, Sung-Ho;Myoung, Woo-Ho;An, Jung-Gi;Hong, Soon-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.3
    • /
    • pp.18-26
    • /
    • 2017
  • The increasing frequency of droughts has been increasing the necessity of utilizing subsurface dams as reliable groundwater resources in areas where it is difficult to supply adequate agricultural water using only surface water. In this study, we analyzed the current status and actual conditions of five agricultural subsurface dams as well as the effect of obtaining additional groundwater from subsurface dams operated as one aspect of the sustainable integrated water management system. Based on the construction methods and functions of each subsurface dam, the five subsurface dams are classified into three types such as those that derive water from rivers, those that prevent seawater intrusion, and those that link to a main irrigation canal. The classification is based on various conditions including topography, reservoir location, irrigation facilities, and river and alluvial deposit distributions. Agricultural groundwater upstream of subsurface dams is obtained from four to five radial collector wells. From the study, the total amount of groundwater recovered from the subsurface dam is turned out to be about 29~44% of the total irrigation water demand, which is higher than that of general agricultural groundwater of about 4.6%.

The Heating Performance Evaluation of Heating System with Building-Integrated Photovoltaic/Thermal Collectors (실험을 통한 건물통합형 태양광·열(BIPVT) 시스템의 난방성능 평가)

  • Jeong, Seon-Ok;Kim, Jin-Hee;Kim, Ji-Seong;Park, Se-Hyeon;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.113-119
    • /
    • 2012
  • The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of PV module with a solar thermal collector which forms one device that produce thermal energy as well as electricity. In many studies various water type PVT collectors have been proposed in effort to increase their electrical and thermal efficiency. The aim of this study is to evaluate the heating performance of heating system combined with PVT collectors that on integrated building roof. For this study, the BIPVT system of 1.5kWp was installed at the experimental house, and it was incorporated with its heating system. From the experimental results, the solar fraction of the heating system with BIPVT was 15%. It was also found that was analyzed that the heating energy for the house can be reduced by 47%, as the heat gained from BIPVT system pre-heated the water used for heating system.

A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system - (다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 -)

  • Nan, Bao-Xuan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

Design and Implementation of Internet Throats and Vulnerabilities Auto Collector for Cyber Threats Management (사이버위협 관리를 위한 인터넷 위협 및 취약점 정보 수집기 설계 및 구현)

  • Lee, Eun-Young;Paek, Seung-Hyun;Park, In-Sung;Yun, Joo-Beom;Oh, Hung-Geun;Lee, Do-Hoon
    • Convergence Security Journal
    • /
    • v.6 no.3
    • /
    • pp.21-28
    • /
    • 2006
  • Beginning flag security it was limited in Firewall but currently many information security solutions like Anti-virus, IDS, Firewall are come to be many. For efficiently managing different kinds of information security products ESM (Enterprise Security management) are developed and operated. Recently over the integrated security management system, TMS (Threat Management System) is rising in new area of interest. It follows in change of like this information security product and also collection information is being turning out diversification. For managing cyber threats, we have to analysis qualitative information (like vulnerabilities and malware codes, security news) as well as the quantity event logs which are from information security products of past. Information Threats and Vulnerability Auto Collector raises the accuracy of cyber threat judgement and can be utilized to respond the cyber threat which does not occur still by gathering qualitative information as well as quantity information.

  • PDF