• 제목/요약/키워드: Collection plate

검색결과 100건 처리시간 0.031초

태양열 집열기 효율곡선에 대한 연구 (The Study of The Collector Efficiency Curve)

  • 신정철
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.198-202
    • /
    • 2014
  • In the solar heat collection system, we can determine how the collector will perform under specific conditions from the efficiency curve. By understanding the basic principles which govern the operation, designers can maximize the output from the collector. Absorptance, transmission and the total heat transfer coefficient were introduced to induce this efficiency curve. Designers who can make use of the implicit information on the curve in this report will generate systems which obtain the best return from their client's investment.

흡열판에 돌출형 삼각 개구부가 설치된 가정용 태양열 공기가열기의 열성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of a Domestic Solar Air Heater with Protruding Triangular Openings on the Absorber Plate)

  • 김현곤;부준홍
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.41-51
    • /
    • 2016
  • A solar air heater was designed for supplementary domestic heating. The absorber plate had a series of protruding notches which had triangular openings on the front surface of the absorber plate to direct partial air flow to the rear surface and to enhance the convective heat transfer to the flowing air. The height of the opening as well as the opening configuration was determined by preceding numerical simulations. The experimental model had an absorber plate of 0.78-m width and 1.0-m length which was coated with black paint. The air temperature increased as much as $18^{\circ}C$ for $90-m^3/h$ flow rate when the absorber plate was inclined by $45^{\circ}$ for a clear-day solar irradiation of about $906W/m^2$. The collector efficiency ranged from 69 to 74%. Considering the simplicity of the structure and low manufacturing cost, the solar air heater might have competence as an auxiliary heating device for domestic use. On-site experimental results are presented with discussion for various solar irradiations and air flow conditions.

지역난방용 태양열시스템 (Solar District Heating System)

  • 백남춘;이진국;윤응상;윤석만;신우철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

점심급식 잔반 조사와 자가 섭취 상태 조사법을 통한 서울 지역 일부 남녀 고등학생의 영양섭취 실태 조사 (Nutrient Intake Determined by School Lunch Plate Waste and by Selfreported Food Consumption of Selected High School Students in Seoul)

  • 이나영;곽동경
    • 대한영양사협회학술지
    • /
    • 제14권1호
    • /
    • pp.1-12
    • /
    • 2008
  • The Purposes of this study were to assess high school students' nutrient consumption at the ordinary time and to analyze nutrient contents and nutrition consumption of lunch. The questionnaires for self-reported food consumption were distributed to 210 students enrolled in a boy's high school and a girl's high school located in Seoul area. A final response rate was 87.1%, excluding responses that had significant missing data. Data of self-reported food consumption and BMI(Body Mass Index) were analyzed with descriptive analysis and t-test using SPSS Win(ver. 12.0). To measure the serving size and the waste amount, data were collected for three meals in a three day period at each school. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Nutrient analyses for the served and consumed menus were performed using CAN-PRO. The result of nutrient intake determined by self-reported food consumption demonstrated 74.2% of boys and 70.0% of the girls did not meet EAR(Estimated Average Requirement) for calcium. In addition, the data collection showed that 60.2% boys and 26.7% girls did not consume EAR for Vitamin B$_1$. Nutrient analyses of the served and consumed menus at school lunch were compared with 1/3 of the Dietary Reference Intakes(DRIs) for this age group. The served menus did not meet 1/3 of the Recommended Intake(RI) for calcium, iron, and vitamin B$_2$. In contrast, the menu provided to students exceeded almost five times(490%) more than the sodium needed for 1/3 of the Adequate Intake(AI). Considering the amount of the students' plate waste, intake of vitamin A and vitamin C were below 1/3 of the RI, and calcium, iron, and vitamin B$_2$ intake were also reduced. Students' sodium consumption still exceeded 1/3 of the AI at 340.0%.

  • PDF

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.

원유의 위생학적 유질변동에 관한 연구 (세균수와 체세포수에 기초한 원유가격제 실시에 따라) (Studies on Variation of Hygienic Quality for Raw Milk (According to Milk Pricing Structure based on Total Bacterial Count & Somatic Cell Count))

  • 이성모;황현순;손봉환;윤화중
    • 한국동물위생학회지
    • /
    • 제17권3호
    • /
    • pp.208-226
    • /
    • 1994
  • From January to December 1993, 3,385 bulk milk samples were collected from 293 herds in Inchon area. Standard plate counts(SPC) and somatic cell counts(SCC) were performed by the method of milk collection, the situation of raising management and monthly. The results obtained are summarized as follows : 1, Annual average SPC and SCC were respectively 638,000 cfu /mm and 647,000 cells /mm. SPC showed an abrupt decrease from January-1,088,000 cfu /mm to December-279,000 cfu /mm, but SCC showed a slow change from January-1,017,000 cells /mm to December -673,000 cells /mm 2. Variation on milk quality(annual average SPC) was shown a wide difference between everyday collection-575,000 cfu /mm and every other day collection-1,243,000 cfu /mm ac-cording to frequency of milk collection from dairy farms. However, there was a little difference In SCC. 3. In the raising scale, average SPC were the lowest in 16~25mi1king cows, and average SCC were the lowest in above 25milking cows. 4. According to types of milking machine, average SPC and SCC of dairy farms that are equipped with pipeline system were respectively 361,000 cfu /mm and 591,000 cells /mm. Those of dairy farms with bucket system were 549,000 cfu /me and 559,000 cells /mm. 5. In the types of management, average SPC an SCC of dairy farms with hired herdsman were 288,000 cfu /mm and 559,000 cells /mm. Those of dairy farms with self-management were 526,000 cfu /mm and 568,000 cells /mm.

  • PDF

유리온실의 태양열 집열방법별 집열효과 (Heating Efficiency of Difference Heat Collection Methods for Greenhouse)

  • 최영하;이재한;권준국;박동금;이한철
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.166-170
    • /
    • 2000
  • 자연열(태양열)을 효율적으로 이용하기위해 1999년부터 2000년 까지 2년간 상면적이 100$m^2$인 3동의 유리온실에 각기 다른 집열시스템을 설치하였다. 즉, 집열면적과 경사도가 각각 24$m^2$, 50$^{\circ}$로서 현재 시판되고 있는 태양열 집열기(평판형, Solar hart Inc.)를 이용하는 방법, 직경과 송풍량이 각각 1m, 2.5m$^{-3}$.m$^{-2}$ .min로서 라디에이터가 부착된 2개의 유동팬을 천장부에 설치하고 천창을 밀폐한 후 온실상부의 열을 집열하는 방법, 온실의 중도리 전부를 물이 순환되는 각관 (75x45x3t, 1m 간격x10줄x온실길이 12m=120m)으로 설치하여 집열하는 방법 등으로 하였다. 각 동마다 지하에 26톤의 저수 능력을 갖는 D2000xW1500xL8600의 축열조를 설치한 후 중간을 막아 저온수조와 고온수조로 구분하였고, 수조 중간 1.5m 높이에 통수로를 내어 일정량의 물(약 15톤)이 지속적으로 순화될 수 있도록 하였다. 최저기온 9$^{\circ}C$로 설정하여 1,000$m^2$를 공간 난방할 경우 난방연료 절감율은 태양열 집열기, 유동팬 및 각관에서 각각 7%, 19%, 28%로 나타났다. 태양열 집열기를 이용하는 대부분의 농가에서는 40~50$m^2$ 정도의 집열면적을 갖는 집열기를 이용하고 있는데 이 경우 년간 난방연료 절감율은 14% 정도로서 경제성이 없으며, 유동팬도 집열효율에 비해 제작, 설치 및 유지비가 과다하게 소요되므로 경제성이 없다. 각관의 경우 관 자체의 자재비나 설치비에 추가부담이 적으면서 집열효율이 비교적 높기 때문에 관의 부식, 골조 표면적 증가에 의한 시설내 차광 증가, 중도리의 각형 구조로 인한 강도저하 등의 문제가 해결되면 집열 방법으로 고려될 수 있을 것이다.

  • PDF

병원급식소의 환자 및 직원 잔식의 처리 현황 조사 (Survey on the Current Disposal Practices of Food Waste left by Patients & Staff in 20 Hospital Foodservices)

  • 김혜진;홍완수
    • 대한영양사협회학술지
    • /
    • 제2권2호
    • /
    • pp.158-167
    • /
    • 1996
  • Food waste left by patients in hospitals is an important indicator of the nutritional adequacy of the patients' diet and of their satisfaction with food. Food wasted by patients or staff in hospitals is one of the most serious problem in hospital foodservice systems. The purpose of this study was to evaluate the disposal practices of food waste in hospital foodservices for providing basic information for an efficient solid waste management. This approach was achieved using a variety of qualitative and quantitative information including general food waste practices and measurement of food waste left by patients and staff in 20 hospital foodservices. The average food wasted by patients and staff per day was 402.20kg and 206.98kg respectively, being total food waste of 578.08kg per day. The mean plate waste of a staff was 115.95g, which was much lower than that of a patient (221.03g). As means of food waste treatment, most hospitals(60%) are using animal feed, followed by means of collection by contracters(15%) and disposal of waste collection after condensing. An average monthly cost for disposing food waste was 915,000 won and average 138.58 minutes were spent to dispose food waste in hospital foodservices.

  • PDF

A new in vitro method for evaluating the antimicrobial activity of toothpaste

  • Lim, Yun Kyong;Kook, Joong-Ki
    • International Journal of Oral Biology
    • /
    • 제46권2호
    • /
    • pp.94-97
    • /
    • 2021
  • The purpose of this study was to introduce a new in vitro method for evaluating the antimicrobial activity of toothpaste, reflecting the actual toothbrushing time and the dilution of toothpaste by salivation. We designed three experimental groups and one negative control group. The experimental groups were (1) 90 μL of toothpaste + 10 μL 1X phosphate-buffered saline (PBS, 9/10 dilution group), (2) 50 μL of toothpaste + 40 μL 1X PBS (1/2 dilution group), and (3) 25 μL of toothpaste + 65 μL 1X PBS (1/4 dilution group). During toothbrushing, saliva is continuously secreted into the oral cavity and the toothpaste concentration is diluted over time during toothbrushing. Therefore, the 1/2 and 1/4 dilution experimental groups were added. The negative control group was toothpaste diluted 20,000-fold with 1X PBS. Miracle Fresh Doctor toothpaste and Streptococcus mitis KCOM 1350, Prevotella intermedia KCOM 1107, Fusobacterium nucleatum subsp. polymorphum KCOM 1322, and Aggregatibacter actinomycetemcomitans KCOM 1306 were used as the toothpaste and target bacterial strains, respectively. The number of bacterial cells plated on agar plates in the negative control group was 1,000 CFU. If the number of colonies on the experimental group plate was less than one, the treatment was considered to have > 99.9% bactericidal activity. These results suggest that this new in vitro method for antimicrobial evaluation could be used as the standard method for testing the antimicrobial activity of toothpaste.