• Title/Summary/Keyword: Collection Performance Evaluation

Search Result 247, Processing Time 0.033 seconds

A Study on Collection Performance Evaluation of Public Libraries in Korea (우리나라 공공도서관의 장서성과평가에 관한 연구)

  • Soo-Sang Lee;Soon-Young Lee
    • Journal of Korean Library and Information Science Society
    • /
    • v.54 no.3
    • /
    • pp.81-104
    • /
    • 2023
  • This study is a case study in which collection performance evaluation was attempted using key performance indicators presented by EBSM or collectionHQ, taking three public libraries located in Geumjeong-gu, Busan as examples. Focusing on the collection performance evaluation, which evaluates the performance of the collection, not only the evaluation of individual libraries, but also the differences in the evaluation results of libraries were reviewed. The key performance indicators used are grubby items, dead items, popular author provision, popular subject provision, overstocked subject areas and understocked subject areas. The main analysis results are as follows. First, in the evaluation of the grubby items, the ratio of grubby items out of all items in all three libraries was low. Second, in the case of all dead items, the ratio was high in all three libraries, It exceeded the base value suggested by collectionHQ. Third, the Top 10 popular authors were identified, and there were differences among libraries. Fourth, in the evaluation of provision of popular subject areas, all three libraries had almost no popular subject areas. Fifth, in the evaluation of overstocked subject areas, there was no overstock at Geumsaem Library, but many at Geumjeong Library and Seodong Library. Sixth, in the subject area evaluation of understocked inventory, only Geumsaem Library showed a lack of inventory.

Study on Performance Evaluation of Marine Kitchen Ventilation Hood (선박용 주방 환기후드의 성능평가에 관한 연구)

  • Kim, Dong-Gyu;Chung, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1373-1379
    • /
    • 2014
  • The purpose of this research is to evaluate the performance of the Ventilation hood and to make better oil collection for improvement. In order to complete the purpose, the research range has limited a kitchen cooking utensil used in preparing food in vessels. Assessment was carried out with reference(ASTM F1704-09) to the specification. Evaluation items of ventilation hood were flow visualization, oil collection rate and noise levels. When filter angle was 40 degrees, oil collection rate was increased by 9%.

Analysis of Current Collection Performance Testing and Result of 350[km/h] Catenary System (350km/h 전차선로 집전성능 시험 및 결과 분석)

  • Heo, Yong-Seok;Lee, In-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.365-369
    • /
    • 2016
  • The 350[km/h] catenary system was successfully opened in Honam high speed line. This 350[km/h] catenary system is firstly constructed in South Korea. Therefore the current collection performance of this system should be tested and evaluated by the authority. This paper describes the testings by running of HEMU-430X train and the evaluation criteria and result analysis to determine whether the performance of the catenary is good or not as a verification of catenary-pantograph interface. In detail, the contact force by pantograph, arcs by loss of contact and uplift amount of the catenary support were measured and discussed as a category of the current collection performance.

Improvement of an Identified Slot Sacn-Based Active RFID Tag Collection Algorithm (인식 슬롯 스캔 기반 능동형 RFID 태그 수집 알고리즘 개선)

  • Yoon, Won-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.3
    • /
    • pp.199-206
    • /
    • 2013
  • This paper proposes a modified tag collection algorithm that improves the drawback of the identified slot scan-based tag collection algorithm presented in a previous paper to improve the tag collection performance in active RFID systems. The previous identified slot scan-based tag collection algorithm is optimized in situations where all the tags store the fixed size of data, so it could not result in a good performance improvement with tags having the variable size of data. The improved tag collection algorithm proposed in this paper first collects the slot size information required for the data transmission from each tag via the identified slot scan phase, and then performs the tag collection phase using the information, which resolves the problem of the previous identified slot scan-based tag collection algorithm. The simulation results for performance evaluation showed that the proposed tag collection algorithm resulted in the almost same tag collection performance as the previous algorithm when all the tags have the same size of data and led a large improvement of the tag collection performance in ISO/IEC 18000-7 unlike the previous algorithm when each tag has a random size of data.

Analysis of Current Collection Performance using Real-time Measurement of Current for Overhead Contact Line on the Track-side (선로변 전차선과 조가선의 전류를 이용한 집전성능 분석 기술)

  • Park, Young;Shin, Seung-Kwon;Lee, Kiwon;Kim, Jaemoon;Kim, Wonha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.573-576
    • /
    • 2013
  • In this paper, analysis method for current collection performance based on real-time current of catenary system is proposed. An innovative method based on track-side of railway system is used for measurement of currents for overhead contact line during the collection with pantograph. The evaluation of a qualitative ratio for current collection performance were conducted using proposed algorithm under various conditions such as laboratory and track-side. To check the validity of our approach, we compared between calculation results from current of contact wire and measurement results from arcing of pantograph using simulator in laboratory conditions. The results show that the behavior of current collection performance were analysis from currents of overhead contact line in AC electric railway system.

Performance Evaluation of Embedded Garbage Collectors in CVM Environment (CVM 환경에서 임베디드 가비지 컬렉터의 성능 평가)

  • Cha, Chang-Il;Kim, Sang-Wook;Chang, Ji-Woong
    • The KIPS Transactions:PartA
    • /
    • v.14A no.3 s.107
    • /
    • pp.173-184
    • /
    • 2007
  • Garbage collection in the Java virtual machine is a core function that relieves application programmers of difficulties related to memory management. In this paper, we evaluate and analyze the performance of GenGC and GenRGC, garbage collectors for embedded Java virtual machines. For performance evaluation, we employ CVM, a real embedded Java virtual machine developed by Sun Microsystems, Inc., as a platform and also use a widely-used SpecJVM98 as a set of benchmark programs. To compare the performance of GenGC and GenRGC, we first evaluate the time of garbage collection and the delay time caused by garbage collection. Second, for more detailed performance analysis of GenRGC, we evaluate the time of garbage collection and the delay time caused by garbage collection while changing the sizes of a block and a frame. Third, we analyze the size of storage space required for performing GenRGC, and show GenRGC to be suitable for embedded environment with a limited mont of memory. Since CVM is the most representative one of embedded Java virtual machines, this performance study is quite meaningful in that we can predict the performance of garbage collectors in real application environments more accurately.

Numerical Performance Evaluation of an Ultra-small Lapple Cyclone Separator (초소형 Lapple 사이클론 집진기의 수치적 성능평가)

  • Park, Sumin;Kwon, Jae-Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.90-95
    • /
    • 2020
  • The purpose of this study is to numerically evaluate the collection performance of an ultra-small Lapple cyclone separator for 1~10 ㎛ particles introduced at flow rate of 10 L/min. The numerical evaluation reveals that a static pressure drop occurs more dominantly inside of the cyclone separator than at the inlet and the vortex finder. Also a fluid flow in the cyclone separator is confirmed to have a helical structure heading upward in the center of cyclone separator and downward in the vicinity of wall. The investigation on dust collection efficiency of the Lapple cyclone separator shows that particles of 4~8 ㎛ diameters are collected at very lower efficiency than other sizes. Then, the cut-point diameter of the cyclone separator is 1.48 ㎛.

Method and Reference Equipment for Evaluation of Travel Time Information (구간 통행시간정보 평가를 위한 기준장비 개발 및 평가 방법 연구)

  • Jeon, Hyeonmyeong;Cho, Yong-Sung;Ahn, Sun-Young;Lim, Sung Han
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.1
    • /
    • pp.64-75
    • /
    • 2022
  • The ITS performance evaluation has been performed in the evaluation of traffic data collection equipment. However, evaluation of the data collection equipment alone cannot guarantee the reliability of the traffic information. So, ITS service evaluation has to be implemented institutionally. In this study, an evaluation method has been prepared to evaluate the accuracy of travel time information in road sections. In addition, a piece of portable reference equipment was developed to collect travel time data on the road. Field tests were performed on two national road sections managed by the Seoul Construction and Management Administration (SCMA) to prepare an evaluation method considering field conditions and evaluate the reference equipment's performance. Based on the test results, the improvement of the reference equipment to collect more samples and the adjustment of collection points were discussed.

Seismic Performance Level Criteria and Evaluation Methods (기존시설물 내진성능평가를 위한 평가항목 분류체계와 평가방법)

  • 김남희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.251-260
    • /
    • 2000
  • Seismic performance evaluation systems require rational classification of structure systems, proper evaluation criteria, and their scoring index for synthesis. Current seismic performance systems need expert judgments based on collection of available data, approximate analysis of important items, and various scoring system. This study presents a three-step seismic performance evaluation system for building structures in Korea. Each evaluation step determines the seismic performance and the method depends on the degree of refinement of analysis. The preliminary step evaluation involves the global attributes of structures such as vertical irregularity, asymmetric plan, redundancy, and age of structures. The second step requires an elastic analysis for estimation of forces acting on critical sections and checks the strength and ductility. The final step requires inelastic capacity of structures. Each stephas own evaluation scheme with proper weighing factor dependent on the importance and consequence. This study applies the fuzzy theory to a scoring method that synthesizes the individual quantity to a representative value.

  • PDF

A Study on the Evaluation of Dynamic Characteristics of the Pantograph for the Korean High-Speed Train through 350km/h Trial Running Test (350km/h 본선 주행시험을 통한 한국형 고속열차 판토그라프의 접촉력 특성 평가 연구)

  • Lee Hi-Sung;Mok Jin-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.342-347
    • /
    • 2005
  • The Korean High-Speed Train(HSR 350x) had been developed by through 'G7-R&D project' in 1996-2002, and has been testing and evaluating it's reliability on the high-speed line until now. A number of core equipments designed and developed by using domestic technologies were boarded on the HSR 350x. In order to verify the performance of HSR 350x and core equipments such as traction system, brake system and pantograph, sophisticated testing and evaluating procedures should be considered and applied. In this paper, the tested and analysed results about the dynamic characteristics of HSR 350x pantograph are introduced in a view point of the mean contact force and it's variation trend, criterion of current collection, and up-lifting of contact wire when the MSR 350x running up to 350 km/h. Through the test and evaluation, we verified that HSR 350x pantograph had an excellent current collection performance and good dynamic characteristics as it had been designed.