• 제목/요약/키워드: Collapse moment

검색결과 245건 처리시간 0.033초

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제13권4호
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

Deterministic and reliability-based design of necessary support pressures for tunnel faces

  • Li, Bin;Yao, Kai;Li, Hong
    • Geomechanics and Engineering
    • /
    • 제22권1호
    • /
    • pp.35-48
    • /
    • 2020
  • This paper provides methods for the deterministic and reliability-based design of the support pressures necessary to prevent tunnel face collapse. The deterministic method is developed by extending the use of the unique load multiplier, which is embedded within OptumG2/G3 with the intention of determining the maximum load that can be supported by a system. Both two-dimensional and three-dimensional examples are presented to illustrate the applications. The obtained solutions are validated according to those derived from the existing methods. The reliability-based method is developed by incorporating the Response Surface Method and the advanced first-order second-moment reliability method into the bisection algorithm, which continuously updates the support pressure within previously determined brackets until the difference between the computed reliability index and the user-defined value is less than a specified tolerance. Two-dimensional reliability-based support pressure is compared and validated via Monte Carlo simulations, whereas the three-dimensional solution is compared with the relationship between the support pressure and the resulting reliability index provided in the existing literature. Finally, a parametric study is carried out to investigate the influences of factors on the required support pressure.

Effects of consecutive earthquakes on increased damage and response of reinforced concrete structures

  • Amiri, Gholamreza Ghodrati;Rajabi, Elham
    • Computers and Concrete
    • /
    • 제21권1호
    • /
    • pp.55-66
    • /
    • 2018
  • A large main shock may consist of numerous aftershocks with a short period. The aftershocks induced by a large main shock can cause the collapse of a structure that has been already damaged by the preceding main shock. These aftershocks are important factors in structural damages. Furthermore, despite what is often assumed in seismic design codes, earthquakes do not usually occur as a single event, but as a series of strong aftershocks and even fore shocks. For this reason, this study investigates the effect and potential of consecutive earthquakes on the response and behavior of concrete structures. At first, six moment resisting concrete frames with 3, 5, 7, 10, 12 and 15 stories are designed and analyzed under two different records with seismic sequences from real and artificial cases. The damage states of the model frames were then measured by the Park and Ang's damage index. From the results of this investigation, it is observed that the sequences of ground motions can almost double the accumulated damage and increased response of structures. Therefore, it is certainly insufficient to ignore this effect in the design procedure of structures. Also, the use of artificial seismic sequences as design earthquake can lead to non-conservative prediction of behavior and damage of structures under real seismic sequences.

CFRP/Al하니콤 샌드위치 복합재 T-Joint 구조물의 기계적 물성에 대한 실험적 연구 (An Experimental Study on the Mechanical Properties of T-Joints Structure using CFRP/Al Honeycomb Sandwich Composite)

  • 조기대;하성록;강광희;김지억;양성철
    • 한국정밀공학회지
    • /
    • 제29권3호
    • /
    • pp.313-318
    • /
    • 2012
  • Application of composite structures on naval ships strongly depends on the mechanical strength and collapse behavior of the T-joints of the whole structure. Because of the weight advantages over single skin composite and bolt fastening joining, three types of T-joints using both honeycomb sandwich composite and adhesive bonding were suggested to determine the effect of T-joint configuration. It was found that joining with a urethane foam block and overlaminates using the secondary co-bonding technique improves T-joint strength.

The uniqueness of the plant mitochondrial potassium channel

  • Pastore, Donato;Soccio, Mario;Laus, Maura Nicoletta;Trono, Daniela
    • BMB Reports
    • /
    • 제46권8호
    • /
    • pp.391-397
    • /
    • 2013
  • The ATP-inhibited Plant Mitochondrial $K^+$ Channel ($PmitoK_{ATP}$) was discovered about fifteen years ago in Durum Wheat Mitochondria (DWM). $PmitoK_{ATP}$ catalyses the electrophoretic $K^+$ uniport through the inner mitochondrial membrane; moreover, the co-operation between $PmitoK_{ATP}$ and $K^+/H^+$ antiporter allows such a great operation of a $K^+$ cycle to collapse mitochondrial membrane potential (${\Delta}{\Psi}$) and ${\Delta}pH$, thus impairing protonmotive force (${\Delta}p$). A possible physiological role of such ${\Delta}{\Psi}$ control is the restriction of harmful reactive oxygen species (ROS) production under environmental/oxidative stress conditions. Interestingly, DWM lacking ${\Delta}p$ were found to be nevertheless fully coupled and able to regularly accomplish ATP synthesis; this unexpected behaviour makes necessary to recast in some way the classical chemiosmotic model. In the whole, $PmitoK_{ATP}$ may oppose to large scale ROS production by lowering ${\Delta}{\Psi}$ under environmental/oxidative stress, but, when stress is moderate, this occurs without impairing ATP synthesis in a crucial moment for cell and mitochondrial bioenergetics.

Magnetization Behavior of Ultra-thin FexCo1-x Alloy on Cr (100) Surface

  • Hossain, M.B.;Kim, C.G.;Chun, B.S.;Kim, W.;Hwang, C.Y.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2013년도 임시총회 및 하계학술연구발표회
    • /
    • pp.15-16
    • /
    • 2013
  • Magnetization behavior of ultra thin $Fe_xCo_{1-x}$ alloy (where x varies from 0 to 100) has been investigated as functions of composition on Cr (100) substrate by using in situ surface magneto optical Kerr effect (SMOKE). It's always show in plane uniaxial magnetic anisotropy at room temperature (RT) & Low temperature (LT). It is observed that composition dependent coercive force maximum at about 30 at % Co and 70 at % Co atomic ratio and minimum near equiatomic site. The relative magnetic moments as composition variation also show magnetization collapse near equiatomic site. The magnetization behaviors of Fe-Co alloy on Cr (100) due to composition varies are supported the order-disordering as well as structural stability bcc (ferromagnetic)/fcc (anti-ferromagnetic) phase stability magnetism.

  • PDF

이중선각구조 선박의 최종굽힘강도와 피로강도에 대한 안전성 평가 (Safety Assessment of Double Skin Hull Structure against Ultimate Bending and Fatigue Strength)

  • 양박달치;이주성
    • 대한조선학회논문집
    • /
    • 제29권1호
    • /
    • pp.93-102
    • /
    • 1992
  • 본 논문에서는 종굽힘하에서 이중선각구조선박의 최종굽힘강도와 피로강도에 대한 신뢰성평가를 다루었다. 최종굽힘강도는 beam-column approach의 개념을 이용하여 구하였고, 보강판의 응력-변형도 곡선들은 소성힌지의 개념을 이용하여 유도하였다. 피로강도는 피로손상에 대한 것만을 고려하였고, 이를 위해 Miner의 손상식을 이용하였다. 갑판에서 가능한 여러 연결부 형태에 대해 그 피뢰신뢰성을 추정하였고 또한 굽힘에 의한 파괴와 피로에 의한 파괴를 동시에 고혀하는 일종의 Series System에 대한 신뢰성을 평가를 하였다.

  • PDF

System and member reliability of steel frames

  • Zhou, W.;Hong, H.P.
    • Steel and Composite Structures
    • /
    • 제4권6호
    • /
    • pp.419-435
    • /
    • 2004
  • The safety level of a structural system designed per code specifications can not be inferred directly from the reliability of members due to the load redistribution and nonlinear inelastic structural behavior. Comparison of the system and member reliability, which is scarce in the literature, is likely to indicate any possible inconsistency of design codes in providing safe and economical designs. Such a comparative study is presented in this study for moment resisting two-dimensional steel frames designed per AISC LRFD Specifications. The member reliability is evaluated using the resistance of the beam-column element and the elastic load effects that indirectly accounts for the second-order effects. The system reliability analysis is evaluated based on the collapse load factor obtained from a second-order inelastic analysis. Comparison of the system and member reliability is presented for several steel frames. Results suggest that the failure probability of the system is about one order of magnitude lower than that of the most critically loaded structural member, and that the difference between the system and member reliability depends on the structural configuration, degree of redundancy, and dead to live load ratio. Results also suggest that the system reliability is less sensitive to initial imperfections of the structure than the member reliability. Therefore, the system aspect should be incorporated in future design codes in order to achieve more reliability consistent designs.

Column-loss response of RC beam-column sub-assemblages with different bar-cutoff patterns

  • Tsai, Meng-Hao;Lua, Jun-Kai;Huang, Bo-Hong
    • Structural Engineering and Mechanics
    • /
    • 제49권6호
    • /
    • pp.775-792
    • /
    • 2014
  • Static loading tests were carried out in this study to investigate the effect of bar cutoff on the resistance of RC beam-column sub-assemblages under column loss. Two specimens were designed with continuous main reinforcement. Four others were designed with different types of bar cutoff in the mid-span and/or the beam-end regions. Compressive arch and tensile catenary responses of the specimens under gravitational loading were compared. Test results indicated that those specimens with approximately equal moment strength at the beam ends had similar peak loading resistance in the compressive arch phase but varied resistance degradation in the transition phase because of bar cutoff. The compressive bars terminated at one-third span could help to mitigate the degradation although they had minor contribution to the catenary action. Among those cutoff patterns, the K-type cutoff presented the best strength enhancement. It revealed that it is better to extend the steel bars beyond the mid-span before cutoff for the two-span beams bridging over a column vulnerable to sudden failure. For general cutoff patterns dominated by gravitational and seismic designs, they may be appropriately modified to minimize the influence of bar cutoff on the progressive collapse resistance.

Numerical simulation of external pre-stressed steel-concrete composite beams

  • Moscoso, Alvaro M.;Tamayo, Jorge L.P.;Morsch, Inacio B.
    • Computers and Concrete
    • /
    • 제19권2호
    • /
    • pp.191-201
    • /
    • 2017
  • External pre-stressing is often used in strengthening or retrofitting of steel-concrete composite beams. In this way, a proper numerical model should be able to trace the completely nonlinear response of these structures at service and ultimate loads. A three dimensional finite element model based on shell elements for representing the concrete slab and the steel beam are used in this work. Partial interaction at the slab-beam interface can be taken into account by using special beam-column elements as shear connectors. External pre-stressed tendons are modeled by using one-dimensional catenary elements. Contact elements are included in the analysis to represent the slipping at the tendon-deviator locations. Validation of the numerical model is established by simulating seven pre-stressed steel-concrete composite beams with experimental results. The model predictions agree well with the experimental results in terms of collapse loads, path failures and cracking lengths at negative moment regions due to service loads. Finally, the accuracy of some simplified formulas found in the specialized literature to predict cracking lengths at interior supports at service loading and for the evaluation of ultimate bending moments is also examined in this work.