• Title/Summary/Keyword: Coliform groups

Search Result 109, Processing Time 0.027 seconds

Effect of Electrolyzed Water and Hot-Air-Drying with UV for the Reduction of Microbial Populations of Undaria pinnatifida (전해수 수세, 열풍건조 및 자외선 조사에 의한 미역의 미생물 감소 효과)

  • Bark, Si-Woo;Kim, Koth-Bong-Woo-Ri;Kim, Min-Ji;Kang, Bo-Kyeong;Pak, Won-Min;Kim, Bo-Ram;Ahn, Na-Kyung;Choi, Yeon-Uk;Cho, Young-Je;Ahn, Dong-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study was conducted to investigate the effects of electrolyzed water (EW) and hot-air-drying with ultraviolet light (UV) to reduce coliform bacteria of Undaria pinnatifida (UP). The UP was washed in the order of 15% EW, tap water (TW), and distilled water (DW) under following conditions: 15% EW for 10 min (washing: 1 time), TW for 1 min, and DW for 10 min (washing: 5 times). Viable cells, coliform, and mold counts were at 102-103 CFU/g in untreated samples. After EW treatment, viable cells, coliform, and molds were not detected in whole samples or on the surface of UP. But, after hot-air-drying at 48°C for 48 h, the number of viable cells, coliform, and molds were 101-105 CFU/g. After hot-air-drying at 48°C for 48 h with UV (12-48 h), viable cells, coliform, and molds were not detected in whole samples or on the surface of UP. In respect of color value, there were no significant changes. In sensory evaluation, the UP with hot-air-drying with UV (12 h) had the highest score in overall preference among UV treatment groups. These results suggest that the treatments at 15% EW for 10 min and hot-air-drying at 48°C for 48 h with UV (12 h) were effective to reduce coliform bacteria of the dried Undaria pinnatifida.

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Bacterial Flora of East China Sea and Yosu Coastal Sea Areas 2. Horizontal Distributions of Bacteria Isolated from The Sea Area (여수 연안 및 동중국해의 세균상 2. 분리균의 수평분포)

  • SHIN Suk-U;JUNG Kyoo-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • The results identified for bacterial flora 174, Vibrio spp.132, and coliform group 183 strains isolated from the areas of last China Sea and Yosu coastal sea during from August 6th. to 14th. 1992 were as follow: 40 strains among the 74 strains of bacteria flora isolated from fast China sea area were Pseudomonas spp.$(54\%)$ and 60 strains among the 100 strains isolated from Yosu sea area were Enterobacteriaceae $(60\%)$. Four strains were Vibrio alginoliticus and one strain of V, parahaemolyticus among 5 strains of genus Vibrio isolated from last China Sea. While 54 strains were V. alginolyticus $(43\%)$ and V, parahaemolyticus $(17\%)$ among 127 strains genus Vibrio isolated from Yosu coastal sea area. Seventy nine strains among the 156 strains of coliform group isolated from Vosu sea area were Escherichia coli I $(51\%)$ and each one strain Citrobacter freundii I and II. 3 strains among 27 strains isolated from last China sea area were E. coli$(11\%)$ and 1 strain of C. freundii I. Coliform group was grouped into 16 types by IMViC system, $44^{\circ}C$, gelatin liquefaction test.

  • PDF

Microbial and Physiochemical Characteristics of Pork Loin Cuts Treated with Ozone Gas During Storage (오존가스 처리가 저장기간 중 포장 돈육의 미생물학적, 이화학적 특성에 미치는 영향)

  • Jeong, Jin-Young;Kim, Chang-Ryoul;Kim, Kwang-Hyun;Moon, Seung-Ju;Kook, Kil;Kang, Suk-Nam
    • Food Science of Animal Resources
    • /
    • v.27 no.1
    • /
    • pp.80-86
    • /
    • 2007
  • This experiment was conducted to investigate the changes of pork meat quality characteristics exposed to ozone gas for 5, 10, and 15 min and then vacuum packaged during storage for 0, 5, 10, 15, and 20 day at $4^{\circ}C$. The ozone gas exposed groups of pork loin cuts (OZM) had slightly higher pH value compared to the control at day 0 and 5 (p<0.01). The 15 min exposure of ozone gas groups showed significantly (p<0.01) higher TBARS value than that of control at the day 15 and 20. However, there was no significant difference in all groups at day 0,5, and 10. The CIE $L^*$ and $b^*$ values of OZM showed no significant difference between control and ozone gas treated groups during storage. The loin cut color of ozone gas exposure for 15 min had significantly lower CIE $a^*$ values than the other groups at day 0,5, and 15 (p<0.01). The aerobic plate count and coliform bacteria count of pork loin cuts exposed ozone gas significantly (p<0.01) was reduced at day 0 by about $0.45-1.04\;log_{10}CFU/g$ and $0.26-0.30\;log_{10}CFU/g$, respectively. As ozone gas exposure time extended, the aerobic plate count and coliform bacteria count of OZM were increased at day 0, 5, and 10 (p<0.01). However, there were no significant differences observed among groups at day 20 in the counts of aerobic and coliform bacteria. In conclusion, the meat cuts exposed to ozone gas for 5 and 10 min before packing may be a reasonable packing method regarding the effects of ozone level on meat oxidation, color change and microbial reduction.

Nutritional and Microbiol Quality Assessment of Chungmukimbab (충무김밥의 영양적 및 미생물적 품질 평가)

  • Choi Jong-Duck;Hwang Young-Suk;Jeoung In-Geon;Lee Da-Jeong;Park Phil-Sook;Park Mi-Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.3
    • /
    • pp.189-195
    • /
    • 2006
  • This research was designed to evaluate the nutritional an microbiol quality assessment of Chungmukimbab purchased from market in Tongyeoung area. Contents of calories, calcium, iron, thiamin and riboflavin in ordinary kimbab and Chungmukimbab were lower than the recommended levels of Korean adult men. So, We suggested that a fruit, beverage and ffod stuff were supplemented to maintain nutritional balance. Total aerobic bacteria and coliform group of just prepared ordinary kimbab and Chungmukimbab samples from market were not significantly different, showing approximately $5.50{\pm}0.38 log_{10} CFU/g,\;2.10{\pm}0.47log_{10}MPN/100g$ in ordinary kimbab, $5.61{\pm}0.42log_{10}CFU/g,\;1.75{\pm}0.34 log_{10} MPN/100g$ in Chungmukimbab, respectively. Total aerobic bacteria of law ingredients of chungmukimbab sample were 3 to $4 log_{10}CFU/g$ in kimbab, seasoning squid and radish roots kimchi, 4 to $5 log_{10}CFU/g$ in boiled fish paste. The coliform groups were 1 to $2 log_{10}$ MPN/100 g in kimbab, seasoning squid and radish roots kimchi, 2 to $3 log_{10}$ MPN/100g in boiled fish paste. Detection rate of E. coli and Staphylococcus aureus counts were 10.0, 12.5% in Chungmu-kimbab, 15.0, 10.0% in seasoning squid, 0, 10.0% in radish roots kimchi respectively, not detected in boiled fish paste samples. During storage at $15^{\circ}C$ for 24 hours, total aerobic counts and coliform groups in ordinary kimbab and Chungmukimbab were increased by the 1.94, $0.97log_{10}CFU/g$, 0.60, 0.72 log10 MPN/100g respectively. Total aerobic counts of Chungmukimbab ingredients increased $0.83{\sim}l.33 log_{10}CFU/g$ at different time

Characteristics Evaluation and Development of Peach Washing System (복숭아의 세척시스템 개발 및 특성 평가)

  • Lee, Hyun-Seok;Kwon, Ki-Hyun;Jeong, Jin-Woong;Kim, Byeong-Sam;Cha, Hwan-Soo
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.446-453
    • /
    • 2009
  • This study was conducted to find condition of improving the quality of peach by using surfacing washing system. The rate of weight loss of A,B groups were showed slower decreasing trend than CT group and the value of soluble solid degree was not different significantly among all groups from the results of stored peach treat with surface washing system of peach in the first experiment. The colory value of surface were increased with increasing storage period in all treatments. Browning pace of A,B groups were slower than control. Emission of carbon dioxide was increased from the results of respiration rate, 6-10 mL/kg/hr $(10^{\circ}C)$ and 32-41 mL/kg/hr $(25^{\circ}C)$. In second experiment with surface washing system of peach, the value of soluble solid was showed with similar value from 10 $Brix^{\circ}$ to 13 $Brix^{\circ}$. The pace of soft rot of EW groups were lower than CT groups from the results of hardness during storage period. The results of colory value was not showed with significant difference in $15^{\circ}C$ and $20^{\circ}C$ storage temperature but changed to browning in EW groups. The moisture contents was from 85% to 90% in all groups. And the count of total microorganism of EW groups were lower than control. Also total coliform of EW groups were negative. In sensory evaluation, washing peach was showed higher value with significant difference in all acceptability.

Effect of fermented earthworm cast feed on the production of high-quality chicken meat (지렁이 분변토 발효사료가 고품질 닭고기 생산에 미치는 영향)

  • Goh, Yong-Gyun;Kim, Jin-Soo;Park, Byung-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.807-817
    • /
    • 2017
  • The present study was undertaken to investigate the effect of fermented earthworm cast feed prepared by using three probiotic mixture with Bacillus subtilis strain on meat quality and growth performance of broiler chickens. A total of 240 one-day-old broiler chickens were randomly assigned to four treatments: 1) control, 2) 0.2% commercial product contain strain of Lactobacillus fermentum (CP), 3) 0.3% fermented earthworm cast feed (FECF3); and 4) 0.5% fermented earthworm cast feed (FECF5). Mean body weight gain, thymus, spleen, and F-bursal weight of birds fed with FECF were higher than those of birds fed with control or CP. Serum IgG levels were higher in birds fed with FECF than those in birds fed with CP or control. Cecal Lactobacillus counts were higher whereas Escherichia, Salmonella, Coliform bacteria, and total aerobic bacteria counts were lower in FECF groups than those in CP or control group. Water holding capacities in FECF groups were higher than those in CP or control group. Ratios of n-6/n-3 in chicken meat were lower in FECF groups compared to those in CP or control group.

간장 효모에 대하여

  • 이한창
    • Korean Journal of Microbiology
    • /
    • v.1 no.1
    • /
    • pp.48-50
    • /
    • 1963
  • The authors have investigated about the microbial contamination of goods which is a criterion of hygienic control. Conducting on investigation, a special attention has been paid on the rate of microbial contamination in the goods, especially in manufacturing process of the softdrink. The authors also made an experiment on total microbes which is the criterion of contamination in each step of the process and in raw materials together with materials to be used for subdividing. Results obtained were as follows : 1) The orgin of microbial contamination was found in bottle cap and in tap water, that is, there appeared 9 colony per ml in bottle cap and 31-74 colony per ml in tap water, respectively. 2) It was found that microbial contamination are 4 colony per ml in average through year. However, it appeared 1 colony per ml in winter and 8 colony per ml in summer. 3) Coliform groups are not detected in goods through a year. 4) There was no variation in number of total microbes after ion exchange resin passage in purification process of tap water. 5) The number of microbes in goods are decreased when the raw materials are treated in high temperature short time (HTST) sterilization.

  • PDF

Safety Monitoring of a Processing Plant for Preparing Raw Oysters Crassostrea gigas for Consumption (생식용 굴(Crassostrea gigas) 작업장의 위생안전성에 대한 모니터링)

  • Kang, Kyung Tae;Park, Sun Young;Choi, Jong-Duck;Kim, Min Joo;Heu, Min Soo;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.2
    • /
    • pp.120-129
    • /
    • 2017
  • This study assessed the safety of raw oysters Crassostrea gigas for consumption during processing in a processing plant. Bacterial contamination (e.g., viable cell counts, coliform groups, Escherichia. coli and pathogenic bacteria) and chemical contamination (e.g., heavy metals and shellfish toxins) were measured on raw oysters, a processing equipment, employees and work areas. No total mercury, lead, paralytic shellfish poison, diarrheic shellfish poison or norovirus was detected in any post-harvested oyster samples. However, the cadmium level ranged from 0.1-0.2 mg/kg. The viable cell count, E. coli and coliform group levels in post-harvested oysters ranged from 4.00-4.54 log CFU/g, ND-210 MPN/100 g and 110-410 MPN/100 g, respectively. The viable contaminating cell counts on employees, equipment and work areas were in the range of $0.90-3.46log\;CFU/100cm^2$. Airborne bacteria in the work areas ranged from 0.60 to 1.81 log CFU/plate/15 min. Thus, no significant health risks were detected in the processing plant.

Impact of Seasonal Conditions on Quality and Pathogens Content of Milk in Friesian Cows

  • Zeinhom, Mohamed M.A.;Abdel Aziz, Rabie L.;Mohammed, Asmaa N.;Bernabucci, Umberto
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.8
    • /
    • pp.1207-1213
    • /
    • 2016
  • Heat stress negatively affects milk quality altering its nutritive value and cheese making properties. This study aimed at assessing the impact of seasonal microclimatic conditions on milk quality of Friesian cows. The study was carried out in a dairy farm from June 2013 to May 2014 at Beni-Suef province, Egypt. Inside the barn daily ambient temperature and relative humidity were recorded and used to calculate the daily maximum temperature-humidity index (mxTHI), which was used as indicator of the degree of heat stress. The study was carried out in three periods according to the temperature-humidity index (THI) recorded: from June 2013 to September 2013 (mxTHI>78), from October 2013 to November 2013 (mxTHI 72-78) and from December 2013 to April 2014 (mxTHI<72). Eighty Friesian lactating dairy cows were monitored in each period. The three groups of cows were balanced for days in milk and parity. Milk quality data referred to somatic cell count, total coliform count (TCC), faecal coliform count (FCC), Escherichia coli count, percentage of E. coli, and Staphylococcus aureus, percentage of fat, protein, lactose, total solid and solid non-fat. Increasing THI was associated with a significant decrease in all milk main components. An increase of TCC, FCC, and E. coli count from mxTHI<72 to mxTHI>78 was observed. In addition, the isolation rate of both S. aureus and E. coli increased when the mxTHI increased. The results of this study show the seriousness of the negative effects of hot conditions on milk composition and mammary gland pathogens. These facts warrant the importance of adopting mitigation strategies to alleviate negative consequences of heat stress in dairy cows and for limiting related economic losses.