• Title/Summary/Keyword: Cold formed steel

Search Result 222, Processing Time 0.027 seconds

Elastic local buckling behaviour of corroded cold-formed steel columns

  • Nie Biao;Xu Shanhua;Hu WeiCheng;Chen HuaPeng;Li AnBang;Zhang ZongXing
    • Steel and Composite Structures
    • /
    • v.48 no.1
    • /
    • pp.27-41
    • /
    • 2023
  • Under the long-term effect of corrosive environment, many cold-formed steel (CFS) structures have serious corrosion problems. Corrosion leads to the change of surface morphology and the loss of section thickness, which results in the change of instability mode and failure mechanism of CFS structure. This paper mainly investigates the elastic local buckling behavior of corroded CFS columns. The surface morphology scanning test was carried out for eight CFS columns accelerated corrosion by the outdoor periodic spray test. The thin shell finite element (FE) eigen-buckling analysis was also carried out to reveal the influence of corrosion surface characteristics, corrosion depth, corrosion location and corrosion area on the elastic local buckling behaviour of the plates with four simply supported edges. The accuracy of the proposed formulas for calculating the elastic local buckling stress of the corroded plates and columns was assessed through extensive parameter studies. The results indicated that for the plates considering corrosion surface characteristics, the maximum deformation area of local buckling was located at the plates with the minimum average section area. For the plates with localized corrosion, the main buckling shape of the plates changed from one half-wave to two half-wave with the increase in corrosion area length. The elastic local buckling stress decreased gradually with the increase in corrosion area width and length. In addition, the elastic local buckling stress decreased slowly when corrosion area thickness was relatively large, and then tends to accelerate with the reduction in corrosion area thickness. The distance from the corrosion area to the transverse and longitudinal centerline of the plate had little effect on the elastic local buckling stress. Finally, the calculation formula of the elastic local buckling stress of the corroded plates and CFS columns was proposed.

Local & Overall Buckling of Cold-Formed Channel Column under Compression at Elevated Temperatures (온도상승에 따른 압축을 받는 냉간성형 C-형강 기둥의 국부 및 전체 좌굴)

  • Baik, Tai-Soon;Kang, Moon-Myung
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.63-72
    • /
    • 2004
  • This paper is developed a computer program to analysis the elastic local and overall buckling stress based on Eurocode 3 Part 1.3 for the flange and web, and Euler equations for columns of cold-formed channel under compression at elevated temperatures. The high temperature stress-strain relationships of steel used this paper are determined according to Eurocode 3 Part 1.2. Critical temperatures and the elastic local buckling stresses of the cold-formed channel columns under compression at elevated temperatures are analysed by the computer program developed in this study. Analysis examples are given to show the applicability of the computer program developed in this study.

  • PDF

Effect of Mo and Cu Contents on Work Hardening of Cold Drawn Stainless Steel 304H Wires for Spring (스프링용 스테인레스강 304H 신선재의 가공경화에 미치는 Mo와 Cu 농도의 영향)

  • Kim S. W.
    • Korean Journal of Materials Research
    • /
    • v.15 no.10
    • /
    • pp.632-638
    • /
    • 2005
  • To investigate the effect of Mo and Cu contents on tensile strength of cold drawn stainless steel 304H wires, metallographical and mechanical tests were performed for the wire specimens drawn to different drawing strains at room temperature. It was confirmed that the contents of Mo ana Cu have little influence on the tensile strength of drawn specimens, even though the strain induced martensite transformation decreased with increasing the contents of Mo and Cu. These results were explained by the strengthening of the formed martensite itself due to the solid solution effect of interstitial solutes, carbon and nitrogen. The contents of these elements were slightly higher in the specimens containing additionally added Mo and Cu.

Effects of Alloy Additions and Annealing Parameters on Microstructure in Cold-Rolled Ultra Low Carbon Steels (극저탄소 냉연강판에서 합금원소 및 어닐링조건이 미세조직에 미치는 영향)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.2
    • /
    • pp.78-86
    • /
    • 2004
  • Effects of the annealing parameters on the formation of ferrites transformed at low temperatures were studied in cold-rolled ultra low carbon steels with niobium and/or chromium. Niobium and chromium were found to be effective in the formation of the low temperature transformation ferrites. The low temperature transformation ferrites more easily formed when both higher annealing temperature and longer annealing time, allowing substitutional alloying elements to distribute between phases, are in combination with faster cooling rate. It was found from EBSD study that the additions of niobium or chromium resulted in the increase in the numbers of high angle grain boundaries and the decrease in those of the low angle grain boundaries in the microstructures. Both granular bainitic ferrite and bainitic ferrite were characterized by the not clearly etched grain boundaries in light microscopy because of the low angle grain boundaries.

Ultimate Strength of branch-rotated T-joints in Cold-formed Square Hollow Sections - Chord flange failure mode - (지관이 회전된 냉간성형 각형강관 T형 접합부의 최대내력(I) - 주관 플랜지 파괴모드 -)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.657-664
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of the new uniplanar T-joints in cold-formed square hollow sections. In the configuration of the new T-joint, only a branch member is orientated to a chord member at 45 degrees in the plane of the truss. This study focused on the branch-rotated T-joints that were governed by chord flange failure in previous studies. Test results of the T-joint in cold-formed square hollow sections revealed a deformation limit of 3%B for $16.7{\leq}2{\gamma}(=B/T){\leq}33.3$ and $0.27{\leq}{\beta}(=b1/B){\leq}0.6$. The existing strength formulae for traditional T-joint were determined and a new yield-line model for the branch-rotated T-joint proposed. Finally, the strength formula on the yield-line analysis was compared with test results and the application range of the proposed formula recommended.

Effect of Alloying Composition and Plastic Deformation on the Microstructure of 22Cr Micro-Duplex Stainless Steel (합금원소와 소성변형이 22Cr 마이크로 듀플렉스 스테인리스강의 미세조직에 미치는 영향)

  • Park, Jun-Young;Ahn, Yong-Sik
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.11
    • /
    • pp.793-800
    • /
    • 2012
  • The effect of cold rolling on the microstructural evolution in 22Cr-0.2N micro-duplex stainless steel was investigated. The 22Cr-xNi-yMn-0.2N duplex stainless steel plates with various Ni and Mn contents were fabricated. The steels were vacuum induction melted and hot rolled, followed by annealing treatment at the temperature range of $1000-1100^{\circ}C$, in which both the austenite and ferrite phases were stable. The volume fraction of the ferrite phase depending on the alloy compositions of Ni and Mn increased with an increase in the annealing temperature. Grain growth in the ferrite phase occurred markedly after cold rolling followed by annealing, while fine recrystallised grains were still found in the austenite phase. A large number of martensite laths was found in the microstructure of cold rolled steels, which should be formed by strain-induced martensite from the austenite phase. The intersections of stacking faults were revealed by TEM observation. The volume fraction of the martensite phase increased with an increase of the reduction ratio by cold rolling.

Strength buckling predictions of cold-formed steel built-up columns

  • Megnounif, A.;Djafour, M.;Belarbi, A.;Kerdal, D.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.4
    • /
    • pp.443-460
    • /
    • 2008
  • The aim of this paper is to propose a design procedure for predicting the buckling strength of built-up, cold-formed steel columns based on the two well known methods; the effective width method and the Direct Strength Method. Several design approaches, based on different elastic buckling solutions, were considered in this investigation. Traditional hand methods, without interaction effects between the different modes, and a new numerical spline finite strip method were used to predict the buckling stresses. All of the proposed methods were compared with experimental data on plain and lipped, built-up columns. Results have shown that the effective width approaches are more accurate than the Direct Strength Method. However, both methods can be investigated using more experimental data to assess a practical design method for built-up columns.

Development of the Optimum Structural Components Model for the Prefabricated Rural House using the Light Gauge Cold-Formed Steel Frame (경량형강을 이용한 조립식 농촌주택의 최적 구조요소 모델 개발)

  • 정남수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.66-76
    • /
    • 1999
  • In this study , the optimum structural components for the rural house design using the light gauge cold-formed steel frame is proposed. The proposed components were optimzed by the developed model composed with the analysis model and LGC database. The analysis model adapts FEA(finite element analysis). LGC database and calculation of element force adapt the design criteria of KISC. The structure of house is divided into header, bearing wall and foof truss. The variable of the each structure of house are defined component which designed by the case of load, aize and space. The designed weight were used for optimization procedure of the divided components.

  • PDF

Strengthening of capacity deficient RC beams - An experimental approach

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Rather, Amer Iliyas;Atif, Mir;Syed, Sayeeda
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.303-310
    • /
    • 2019
  • Any revision of seismic codes usually demands a higher capacity from structural members, making existing structures unsafe particularly from strength considerations. Retrofitting of capacity deficient members is very suitable for tackling such situations. This paper presents an experimental study on different retrofitting measures adopted for strengthening a series of reinforced concrete (RC) beams. Four identical RC beam specimens were casted, out of which three specimens were strengthened by different schemes (viz., bolted hot rolled flat, bolted cold-formed steel channel, and carbon fibre reinforced polymer (CFRP) laminate, respectively) on their tension face and tested under four-point monotonic loading. This study focuses on the investigation of the flexural behaviour of these retrofitted beams, observed in terms of strength and stiffness. It was concluded that all retrofitting measures improved the structural performance of these beams. However, the cost involved with each strengthening mode was proportional to the improvement in the performance achieved.

A Study on the Flexural Strength Capacity of Wall Stud Assembly (경량형강 스터드 벽체의 휨강도에 관한 연구)

  • Kwon, Young Bong;Chung, Hyun Seok;Kim, Gap Deuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2003
  • An investigation on the structural behavior of cold-formed steel lipped C-section stud for interior walls or partitions was carried out. This experimental research was carried out to study the ultimate and service load capacity of stud assemblies that are subjected to lateral loads. Each test specimen consisted of three or four lipped C-section studs and two C-section tracks that restrained both ends. The major factors considered in this experiment were the perforation on the web, the connection of the bridge channel and the special clip. The effect of the plaster board and the ply wood, which were attached to the tension flange on the flexural strength, was also investigated. Thereafter, the test strength capacities were compared with the nominal strength, based on the AISI Specifications (1996).