• 제목/요약/키워드: Cold flow

검색결과 1,092건 처리시간 0.026초

로봇 냉각을 위한 수냉식 냉각판의 열적 성능 평가 (Thermal Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 강상우;이석원;황규대;김서영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1864-1869
    • /
    • 2007
  • In this study, we compare thermal performance between four different types of cold plates for humanoid robot cooling. Two commercially available cold plates made of copper have different dimensions and internal flow paths: One has $20{\times}20$ $mm^2$ base area with micro-channels and the other has $62.5{\times}62.5$ $mm^2$ base area with 85 round pin-fins. And two different types of cold plates of $20{\times}20$ $mm^2$ base area with 7 mm high are made of PC (polycarbonate), which aims to reduce the weight of cooling system. All cold plates are mounted on a $20{\times}20$ $mm^2$ copper block with two cartridge heaters of 30 $W/cm^2$. The overall heat transfer coefficient and thermal resistances for the liquid-cooled cold plates are obtained. The copper cold plate with micro-channels showed the best performance. Polycarbonate cold plates display fairly good thermal performance with more reduced system weight.

  • PDF

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계 (Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions)

  • 정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.

다단 미세 치형 허브기어의 프레스 성형기술개발 (Development of Press Forming Technology for the Multistage Fine Tooth Hub Gear)

  • 김동환;고대철;이상호;변현상;김병민
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.44-51
    • /
    • 2006
  • This paper deals with the aspects of die design for the multistage fine tooth hub gear in the cold forging process. In order to manufacture the cold forged product for the precision hub gear used as the ARD 370 system of bicycle, it examines the influences of different designs on the metal flow through experiments and FE-simulation. To find the combination of design parameters which minimize the damage value, the low gear length, upper gear length and inner diameter as design parameters are considered. An orthogonal fraction factorial experiment is employed to study the influence of each parameter on the objective function or characteristics. The optimal punch shape of fine tooth hub gear is designed using the results of FE-simulation and the artificial neural network. To verify the optimal punch shape, the experiments of the cold forging of the hub gear are executed.

한열허실변증(寒熱虛實辨證)을 이용한 비정격(脾正格) 적응증 고찰 (A Literature Study on the Application of Spleen Tonifying Sa-Am Acupuncture in the Diagnosis of Cold-Heat & Deficiency-Excess)

  • 최준수;임윤경
    • Journal of Acupuncture Research
    • /
    • 제23권5호
    • /
    • pp.31-37
    • /
    • 2006
  • Objectives & Methods : We investigated the cases for which spleen tonifying Sa-Am acupuncture was applied in ${\ulcorner}$Sa-Am-chim-gu-jeong-jeon(舍巖鍼灸正傳)${\lrcorner}$ and classified them according to the concepts of cold-heat & deficiency-excess for a better understanding of the application of spleen tonifying Sa-Am acupuncture. Results : 1. Tonification of Spleen Sa-Am acupuncture can be used to treat heat syndromes such as deficient fire caused by collapse of the spleen qi, stagnation of evil qi or spleen yin deficiency, by way of tonifying spleen qi, activating the flow of qi and blood or harmonizing spleen yin and yang. 2. Tonification of Spleen Sa-Am acupuncture can be used to treat cold syndromes such as weakness of spleen yang by way of promoting fire to generate earth, strengthening spleen yang and raising the clear yang. 3. Tonification of Spleen Sa-Am acupuncture can be used to treat deficiency syndromes such as malnutrition or poor appetite caused by spleen deficiency by way of tonifying spleen qi. 4. Tonification of Spleen Sa-Am acupuncture can be used to treat excess syndromes such as stagnation of qi and blood, abdominal mass or toxication by way of tonifying spleen qi and promoting the flow of qi and blood.

  • PDF

산업체 급식소에서 제공되는 콩국수의 미생물적 품질관리에 관한 연구( I ) (A Study on Microbiological Quality & Safty Control of Cold Sybean Noondles serviced by an Industry Foodservice Establishment)

  • 주선의;김혜영
    • 한국식품조리과학회지
    • /
    • 제4권2호
    • /
    • pp.71-79
    • /
    • 1988
  • This study is written to look into microbiological quality by passage of time and holding methods after making foods, by means of evaluating time, temperature and microbiological quality during various phases in product flow of cold soybean noodles serviced by an industry feeding operation for 500 persons a day, measuring pH & Aw and analyzing factors affecting microbiological growth conditions. The results were as follows: 1. According to phases in product flow of cold soybean noodles, it showed 15.6 hours of mean of needed time, $24.2^{\circ}C$ of room temperature, 5.1~7.6 of pH value & 0.95~0.98 of Aw except dry noodles. These conditions were good for multipling of microbe, and the phases with potential sanitary danger were ingredient, pre-preparation, holding before assembly and service and assembly & service. 2. As for holding methods and passage of time, holding at cold table was more effective than holding at room temperature as time past. 3. As for equipments using for making food, dipper, basket, kitchen board & kitchen towel showed high microbiological value in total aerobic plate counts and kitchen towel and stainless-steel were showed high microbioloical value in coliform counts. 4. E. coli, food poisoning bacteria was detected from barrel filled with soybean soup and also soybean itself.

  • PDF

Optimization of Atmospheric Cold Plasma Treatment with Different Gases for Reduction of Escherichia coli in Wheat Flour

  • Lee, Jeongmin;Park, Seul-Ki;Korber, Darren;Baik, Oon-Doo
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권6호
    • /
    • pp.768-775
    • /
    • 2022
  • In this study we aimed to derive the response surface models for Escherichia coli reduction in wheat flour using atmospheric cold plasma (ACP) with three types of gas. The jet-type atmospheric cold plasma wand system was used with a 30 W power supply, and three gases (argon, air, and nitrogen) were applied as the treatment gas. The operating parameters for process optimization considered were wheat flour mass (g), treatment time (min), and gas flow rate (L/min). The wheat flour samples were artificially contaminated with E. coli at a concentration of 9.25 ± 0.74 log CFU/g. ACP treatments with argon, air, and nitrogen resulted in 2.66, 4.21, and 5.55 log CFU/g reduction of E. coli, respectively, in wheat flour under optimized conditions. The optimized conditions to reduce E. coli were 0.5 g of the flour mass, 15 min of treatment time, and 0.20 L/min of nitrogen gas flow rate, and the predicted highest reduction level from modeling was 5.63 log CFU/g.

비정상 열확산 현상 의 실험적 연구 (Experimental study of unsteady thermally stratified flow)

  • 이상준;정명균
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.767-776
    • /
    • 1985
  • 본 연구에서는 초기 조건(입구 R$_{i}$수)의 변화에 따른 속도 분포, 온도 분 포, 확산율, 계면의 변화등을 연구하며, 난류 혼합과 계면의 불안정에 기인한 속도장 과 온도장의 변화과정을 가시화 사진과 비교 분석한다.다.

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석 (Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy)

  • 한단비;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.