• Title/Summary/Keyword: Cold air system

Search Result 387, Processing Time 0.03 seconds

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

해양심층수 이용 냉방시스템에 관한 연구 (A Study on the Air Conditioning System by the Low Temperature Energy of the Deep Seawater)

  • 박성제;김효봉;김현주
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.253-256
    • /
    • 2006
  • This paper shows the study on application of the law temperature energy in the deep seawater. Deep, cold seawater has long been recognized as a valuable ocean energy resource. Recently, research and experimentation has been conducted on energy systems using deep seawater: deep seawater air conditioning system, ice-making device, salt and fresh-water manufacturing system and the Spray freeze drying system for extracting valuable material of the deep seawater. They are technically and economically feasible today: once installed, the energy is inexhaustible and there are no adverse environmental impacts. Because of the economy of scale in the air conditioning system, the seawater A/C system is most appropriate for supplying multiple buildings or hotels in a coastal area.

  • PDF

고온유동 조건의 분출냉각 실험을 위한 시험장치의 설계 및 해석 (Design and Analysis of Test Facility for the Experiment of Transpiration Cooling in Hot-flow Condition)

  • 이정민;나재정;강경택;권민찬;황기영
    • 한국추진공학회지
    • /
    • 제17권2호
    • /
    • pp.46-56
    • /
    • 2013
  • 고온 공기 공급시스템이 있는 시험장치는 분출냉각 소재를 개발하고 이를 실험적으로 평가하는데 필요한 장치이다. 본 연구에서 아크-플라즈마 발생기, 찬 공기가 공급되는 Plenum 챔버, 시험부로 구성된 시험장치를 설계하였으며, 내부 유동해석을 수행하였다. CFD 결과로부터 설계된 Plenum 챔버가 열적으로 안전하고 챔버 내부에서 초고온의 공기와 찬 공기가 잘 혼합되고 있음을 확인할 수 있었다. 또한, 시험부로 균질한 유동을 공급할 수 있는 구조로 시험장치가 설계되었음을 검증하였다.

폭설에 대한 예측가능성 연구 - 2008년 3월 4일 서울지역 폭설사례를 중심으로 - (On the Predictability of Heavy Snowfall Event in Seoul, Korea at Mar. 04, 2008)

  • 류찬수;서애숙;박종서;정효상
    • 한국환경과학회지
    • /
    • 제18권11호
    • /
    • pp.1271-1281
    • /
    • 2009
  • The heavy snowfall event over the eastern part of Seoul, Korea on Mar. 04, 2008 has been abruptly occurred after the frontal system with the heavy snowfall event had been past over the Korean peninsula on Mar. 03, 2008. Therefore, this heavy snowfall event couldn't be predicted well by any means of theoretical knowledges and models. After the cold front passed by, the cold air mass was flown over the peninsula immediately and became clear expectedly except the eastern part and southwestern part of peninsula with some large amount of snowfall. Even though the wide and intense massive cold anticyclone was expanded and enhanced by the lowest tropospheric baroclinicity over the Yellow Sea, but the intrusion and eastward movement of cold air to Seoul was too slow than normally predicted. Using the data of numerical model, satellite and radar images, three dimensional analysis Products(KLAPS : Korea Local Analysis and Prediction System) of the environmental conditions of this event such as temperature, equivalent potential temperature, wind, vertical circulation, divergence, moisture flux divergence and relative vorticity could be analyzed precisely. Through the analysis of this event, the formation and westward advection of lower cyclonic circulation with continuously horizontal movement of air into the eastern part of Seoul by the analyses of KLAPS fields have been affected by occurring the heavy snowfall event. As the predictability of abrupt snowfall event was very hard and dependent on not only the synoptic atmospheric circulation but also for mesoscale atmospheric circulation, the forecaster can be predicted well this event which may be occurred and developed within the very short time period using sequential satellite images and KLAPS products.

난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구 (Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period)

  • 이건호;김현수;고영우;손영주
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

하이브리드법을 이용한 열전냉각의 수치해석 연구 (Computer Simulation Study of the Thermoelectric Cooling by Hybrid Method)

  • 김남진;이재용;김종보
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.97-108
    • /
    • 2000
  • The purpose of this study is to minimize the heat transfer surface area and cold fluid exit temperature of heat exchanger which applied to the refrigeration and air-conditioning system by utilizing the thermoelectric principle. Both uniform and non-uniform current distribution methods which applied to the analysis of the TE elements that incorporates heat exchanger were investigated. The non-uniform current distribution method had the better coefficient of performance and had the lower cold fluid exit temperature of the TE cooling system than the uniform current distribution method. It was found that if a TE cooling system incorporates a heat exchanger, a non-uniform current distribution should guarantee to the lowest cold fluid exit temperature. Also, the hybrid method (combination of the uniform and non-uniform current distribution method) is investigated to achieve the best results by combining the uniform and non-uniform current distributions. The results show that it can lower the cold fluid exit temperature and reduce the heat transfer surface area for the parallel flow arrangement if we apply the constant current in some entry region and the non-uniform increasing current in the direction of the cold fluid flow afterwards.

  • PDF

CCM(Cold Chain Management)과 연계된 RFID 패키징 국제 기술 표준의 분석 (A Study on the International Standard for CCM Related RFID Packaging Technology)

  • 윤성영;차경호;박수일;김재능
    • 한국포장학회지
    • /
    • 제15권2호
    • /
    • pp.67-73
    • /
    • 2009
  • The introduction of radio frequency identification (RFID) technology into cold chain system will be essentials for the better quality preservation of chilled products in the near future. The object of this study is to analyze the trends of international standardization activity for cold chain system and RFID packaging. The standardization of RFID technology is related to SC31 of ISO/IEC JTC1. The established standard from EPCglobal includes the air interface of UHF substitute actors, the control of EPC tag data and the event collected from RFID readers, the directory services and information storage of ONS and EPCIS, and securities. Also, EPC standards include the sensor functions of the cold chain. In Korea, the RFID packaging related techniques and their engineering standard are less studied as compared with Europe or North America. For effective application of RFID in the cold chain and packaging, scientific and systematic researches on RFID, including technical standards for domestic RFID frequency, will be key elements for preoccupation of these application techniques.

  • PDF

연삭 가공시 Mist의 냉각효과에 관한 연구 (A Study on the Cooling Effects of Mist in the Grinding)

  • 이석우;최헌종;김대중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.918-921
    • /
    • 2001
  • In grinding process, the heat of $1200^{\circ}$~$1500^{\circ}$ on the grinding area between grinding wheel and workpiece is generated. It decreases the surface integrity of workpiece and causes the thermal damages such as the deformed layer, residual stress and grinding burn. Generally coolant is widely used for preventing the heat generation on the grinding area, but it deteriorates the working condition by polluting the atmosphere of workplace and in the end pollutes the environment. The grinding methods using the compressed cold air and mist are the cooling methods to substitute conventional coolant. They can decrease the environmental pollution through not using coolant any more or minimizing it. In this study, the cooling effects of grinding methods using the compressed cold air and mist have been investigated. The grinding system equipped with the water bathe and mist spray nozzle was developed. The energy partition to workpiece through measuring the temperature on the workpiece surface was calculated. The surface integrity of workpiece and thermal damage like the deformed layer were analyzed.

  • PDF

동해의 해무 예측 시스템 연구 (A Study on Prediction System of Sea Fogs in the East Sea)

  • 서장원;오희진;안중배;윤용훈
    • 한국해양학회지:바다
    • /
    • 제8권2호
    • /
    • pp.121-131
    • /
    • 2003
  • 동해안에서 지난 20년 동안 발생한 월별 안개 발생빈도와 지속시간 분석에 의하면 1월, 2월, 11월, 12월의 안개 발생빈도는 거의 전무함을 알 수 있다. 이 현상은 태백산맥으로부터 동쪽으로 경사를 이루어 복사 안개의 발생이 어려운 지형 특징을 가지고 있기 때문으로 사료된다. 반면에 안개발생빈도의 90%이상을 차지하는 봄, 여름철의 안개 발생 원인은 크게 3가지로 분류된다. 첫 번째는 증기해무로서 오호츠크해 고기압의 확장으로 찬 북동기류가 동해상으로 이류하여 발생한다. 두 번째는 이류해무로서 따뜻한 기단이 상대적으로 찬 해수면 위로 이류하여 냉각, 포화되어 발생한다. 세 번째는 전선해무로써 저기압이 동해상으로 이동하여 수증기가 공급된 상태에서 한랭 전선 후면의 찬공기가 이류하면서 발생한다 한편, 해상풍, 상대습도, 운저고도, 시정 등의 예측과 동해 해역의 수직단면에서 안개 예측이 가능한 해무예측시스템(DUT-METRI)을 구축하여 사례기간의 해무를 모사하였, 위성자료로부터 이를 검증하였다.

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.