• 제목/요약/키워드: Cold Spot

검색결과 119건 처리시간 0.034초

IMPROVEMENT OF FATIGUE LIFE IN POST-WELD COLD WORKED ALUMINUM RESISTANT SPOT WELDS

  • Kim, D.;Blake, D.M.;Ryu, S.J.;Lim, B.S.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.579-584
    • /
    • 2006
  • Aluminum Resistance Spot Weld(Al RSW) is an enabling technology for body assembly of low mass fraction vehicles. Due to the unreliable durability of spot-welded joints, applications of Al RSW are limited. This study presents experimental investigation on the use of a post-weld cold working process to improve the fatigue strength of Al RSW. The post-weld cold working process includes special shaped indenters that are pressed or driven into the structure to induce compressive residual stresses. The mechanical properties of the post-weld cold worked Al RSW were investigated, including the experimental results of fatigue and micro-hardness tests. Comparisons of the mechanical properties and qualitative results between the as-welded RSW specimens and the post-weld cold worked RSW specimens are discussed. The post-weld cold worked Al RSW samples had an increase in both microhardness and fatigue life.

BAF 소둔의 저온점 변화에 관한 연구

  • 김순경;이승수;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.327-331
    • /
    • 1997
  • As demand for various kinds and small lot products has been increasing, batch annealing has been appreciated for its small restiction for the opteration. The cold spot of the coil is very important in the BAF(Batch annealing furnace) annealing process. Because of the annealing cycle time in the BAF, annealing was decided on the cold spot of the coil. So, we tested the effect,variation of cold spot, for hydrogen contents of atmospheric gas at the annealing furnace. As a result of several investigations. We confirmed the following characteristics ; after the heating and soaking,the cold spot of coil moved to 1/3 of coil thickness in the NHx atmospheric gas, but the mid point of the coil thickness is the cold spot in the Ax or .H/sub2. atmospheric gas. Therefore, the use of hydrogen instead of nitrogen as the protective gas,combined with high convection in batch annealing furnaces, has shown that considerable increases in furnace output and material quality are attainable. Owing to the low density, high diffusion and reducing character of hydrogen, a better transfer resulting in uniform material temperatures and improved coil surfaces can be achieved.

FEM에 의한 일반냉연강판 및 고장력강판의 점용접 피로수명해석 (Fatigue Life Analysis of Spot Weldment of Cold Rolled and High Strength Steel Using FEM)

  • 유효선;양성모;강희용;김홍건;김규상
    • 한국공작기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.58-63
    • /
    • 2008
  • Cold rolled and high strength steel were used for vehicle bodys to satisfy environmental regulation and improve fuel ratio. This paper presented a method far determining the fatigue life of cold rolled steel sheet EZNCEN and high strength steel sheet HS40R spot weldment used in vehicles. We can estimate the fatigue life of the spot weldments from the MSC/FATIGUE using the finite element method. The maximum load is found in the nugget part of both surfaces. The cold rolled steel and the high strength steel showed the maximum stress 746MPa and 730MPa in the effective nugget part when the weld current was 8KA and 7KA, respectively. Also the some weld current of the cold rolled steel and high strength steel is applied, the fatigue life of high strength steel is obtained about four times longer than the cold rolled steel.

둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성 (Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature)

  • 장혁진;양종경;김남군;정영일;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

해양환경 공간분포 패턴 분석을 위한 공간자기상관 적용 연구 - 광양만을 사례 지역으로 - (Application of Spatial Autocorrelation for the Spatial Distribution Pattern Analysis of Marine Environment - Case of Gwangyang Bay -)

  • 최현우;김계현;이철용
    • 한국지리정보학회지
    • /
    • 제10권4호
    • /
    • pp.60-74
    • /
    • 2007
  • 해양환경의 시공간적 분포 패턴을 정량적으로 분석하기 위해 남해 광양만 해양환경 관측 자료를 이용하여 글로벌 및 국지적 공간자기상관 통계를 적용하였다. 연구지역 전체의 해양환경 분포 패턴을 이해하기 위해 Moran's I, General G와 같은 글로벌 공간자기상관 지수를 사용하였으며, 대상 피쳐(feature)와 이웃 피쳐들과의 유사성 정도를 측정하고 hot spot 및 cold spot을 탐지하기 위해 국지적 Moran's I ($I_i$), $G_i{^*}$와 같은 LISA(local indicators of spatial association)를 사용하였고, 공간 군집 패턴의 신뢰성은 Z-score를 통한 통계적 유의성 검증을 수행하였다. 공간 통계 결과를 통해 년 중 해양환경 공간분포 패턴의 변화를 정량적으로 알 수 있었는데, 일반 해양수질, 영양염, 클로로필 및 식물플랑크톤은 여름철에 강한 군집 패턴을 보였다. 글로벌 지수에서 강한 군집 패턴을 보였을 때 속성 값의 공간적인 변화가 심한 음적 $I_i$ 값을 가지는 전선지역이 탐지되었다. 또한, 글로벌 지수에서 임의적 패턴을 보였을 때 국지적 지수인 $G_i{^*}$에서는 좁은 지역에서 hot spot과(또는) cold spot이 탐지되었다. 따라서 글로벌 지수는 연구 지역 전체 군집 패턴의 강도와 시계열적 변화 과정 탐지에, 국지적 지수를 통해서는 hot spot과 cold spot 위치 추적에 유용함을 알 수 있었다. 해양환경 공간분포 패턴과 군집 특성을 정량화는 것은 해양환경을 보다 깊이 이해할 수 있도록 할 뿐 아니라, 패턴의 원인을 찾는데도 중요한 역할을 할 것이다.

  • PDF

둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성 (Dependence of Round type electrodeless lamp according to ferrite core and cold spot temperature)

  • 오슬이;김남군;양종경;정영일;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.65-69
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of electrodeless lamp are related to ferrite core and cold spot temperature.

  • PDF

둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성 (Dependence of Round Type Electrodeless Lamp According to Ferrite Core and Cold Spot Temperature)

  • 김남군;양종경;이종찬;한후석;박지식;박대희
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.833-838
    • /
    • 2008
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature. Additionally, spectrum, color temperature and coordination are measured to check that is relation with ambient temperature.

HNx 분위기가스중에서 BAF소둔시 코일의 온도변화에 관한 연구 (A Study on Temperature Variation of Coil on BAF Annealing in HNx Atmospheric Gas)

  • 전언찬;김순경
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1227-1234
    • /
    • 1994
  • A cold spot temperature control system for the batch annealing furnace has been established in order to reduce energy consumption which is essential to improve productivity and stabilize the properties of products. A relationship between annealing cycle time and gas flow rate is developed and also for the variation of coil cold spot temperature with time during heating, and actual temperature measurements at mid-width of each coil during soaking. The results of the temperature variation effect on the cold rolled steel sheet batch annealing are as follows. (1) Cooling rate increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component change. (2) In case of short time heating, the slowest heating part is the center of B coil and in case of ling time heating, the low temperature point moves from the center of coil to inside coil. (3) The outside of top coil is the highest temperature point under heating, which becomes the lowest temperature point under cooling. (4) Soaking time determination depends on the input coil width, and soaking time for quality homogenization of 1214 mm width coil must be 2 hours longer than that of 914 mm width coil.

75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구 (A study on coil temperature bariation in 75% hydrogen batch annealing furnace)

  • 전언찬;김순경
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF