• 제목/요약/키워드: Cold Flow Test

검색결과 224건 처리시간 0.03초

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권4호
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

4각 안내덕트 루프형상에 의한 난류특성변화 수치해석 (A Numerical Study of the Turbulent Flow Characteristics in the Inlet Transition Square Duct Based on Roof Configuration)

  • 유근종;최훈기;최기림;신병주
    • 대한기계학회논문집B
    • /
    • 제33권7호
    • /
    • pp.541-551
    • /
    • 2009
  • Configuration of the inlet transition square duct (hereinafter referred to as "transition duct") for heat recovery steam generator (hereinafter referred to as "HRSG") in combined cycle power plant is limited by the construction type of HRSG and plant site condition. The main purpose of the present study is to analyze the effect of a variation in turbulent flow pattern by roof slop angle change of transition duct for horizontal HRSG, which is influencing heat flux in heat transfer structure to the finned tube bank. In this study, a computational fluid dynamics(CFD) is applied to predict turbulent flow pattern and comparisons are made to 1/12th scale cold model test data for verification. Re-normalization group theory (RNG) based k-$\epsilon$ turbulent model, which improves the accuracy for rapidly strained flow and swirling flow in comparison with standard k-$\epsilon$ model, is used for the results cited in this study. To reduce the amount of computer resources required for modeling the finned tube bank, a porous media model is used.

기체주입 충돌제트의 분무특성에 관한 실험적 연구 (Experimental Study on the Spray Characteristics of Aerated Impinging Jets)

  • 이근석;윤영빈;안규복
    • 한국분무공학회지
    • /
    • 제24권4호
    • /
    • pp.185-193
    • /
    • 2019
  • The effervescent atomizer is one of twin-fluid atomizers that aeration gas enters into bulk liquid and two-phase flow is formed in the mixing section. The effervescent atomizer requires low injection pressure and small amount of aeration gas, as compared to other twin-fluid atomizers. In this study, cold flow test was conducted to investigate the spray characteristics of aerated impinging jets. The present effervescent impinging atomizers were composed of the aerator device and like-on-like doublet impinging atomizer which had different impinging angles. To analyze the spray characteristics such as breakup length and droplet size distribution, the image processing technique was adopted by using instantaneous images at each flow condition. Non-dimensional parameters, induced by the homogeneous flow model, were used to predict the breakup length. The breakup length was decreased with the mixture Reynolds number and impinging angle increasing. The result of droplets showed that the size distribution was axisymmetric about the center of the injector and their diameter tended to decrease with increasing GLR.

탄화수소계 냉매들과 DME의 수평 평활관내 흐름 응축 열전달 특성 (Flow Condensation Heat Transfer Characteristic of Hydrocarbon Refrigerants and DME in Horizontal Plain Tube)

  • 박기정;이민행;박현신;정동수
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.545-554
    • /
    • 2007
  • Flow condensation heat transfer coefficients(HTCs) of R22, propylene, propane, DME and isobutane are measured on a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed refrigerant saturation temperature of $40{\pm}0.2^{\circ}C$ with mass fluxes of 100, 200, $300kg/m^2s$ and heat flux of $7.3\sim7.7kW/m^2$. The data are obtained in the vapor Quality range of $10\sim90%$. Test results show that at same mass flux the flow condensation HTCs of propylene, propane, DME and isobutane are higher than those of R22 by up to 46.8%, 53.3%, 93.5% and 61.6% respectively. Also well-known correlations developed based upon conventional fluorocarbon refrigerants predict the present data within a mean deviation of 30%. Finally, the pressure drop increase as the mass flux and Quality increase and isobutane shows the highest pressure drop due to its lowest vapor pressure among the fluids tested.

DEFORM$^{TM}$을 이용한 SKH9 고속도공구강의 경도 예측 (Estimation of Hardness using DEFORM$^{TM}$ in SKH9 High Speed Steel)

  • 박준홍;성장현;김영희;이해우;전언찬;박영철
    • 열처리공학회지
    • /
    • 제20권4호
    • /
    • pp.175-180
    • /
    • 2007
  • The hardness of cold-forged products is in close relationship with its effective strain. This study presented the estimating method of hardness for cold-forged SKH9 products without hardness tests in view of resistance to plastic deformation using finite element code, DEFORM$^{TM}$. The flow stress equation obtained from the compression test was only used as a basic data to estimate the relationship between effective strain and hardness. In addition, this new estimating method was applied to the cold-forged product which was widely used in industrial field to show the feasibility. As a result, the predicted hardness numbers through FE simulation showed good agreement with the measured hardness numbers. It is possible to estimate the hardness not by hardness tests, but by only computer simulations for the deformed products. Also, effective strain values were possibly estimated by measuring hardness numbers, and vice versa.

Optimization of hydraulic section of irrigation canals in cold regions based on a practical model for frost heave

  • Wang, Songhe;Wang, Qinze;An, Peng;Yang, Yugui;Qi, Jilin;Liu, Fengyin
    • Geomechanics and Engineering
    • /
    • 제17권2호
    • /
    • pp.133-143
    • /
    • 2019
  • An optimal hydraulic section is critical for irrigated water conservancy in seasonal frozen ground due to a large proportion of water leakage, as investigated by in-situ surveys. This is highly correlated with the frost heave of underlain soils in cold season. This paper firstly derived a practical model for frost heave of clayey soils, with temperature dependent thermal indexes incorporating phase change effect. A model test carried out on clay was used to verify the rationality of the model. A novel approach for optimizing the cross-section of irrigation canals in cold regions was suggested with live updated geometry characterized by three unique geometric constraints including slope of canal, ratio of practical flow section to the optimal and lining thickness. Allowable frost heave deformation and tensile stress in canal lining are utilized as standard in computation iterating with geometry updating while the construction cost per unit length is regarded as the eventual target in optimization. A typical section along the Jinghui irrigation canal was selected to be optimized with the above requirements satisfied. Results prove that the optimized hydraulic section exhibits smaller frost heave deformation, lower tensile stress and lower construction cost.

Stress Relaxation Behavior of Cold-worked and Annealed Zircaloy-4 Tubing

  • Rheem, K.S.;Choi, C.B.;Park, W.K.
    • Nuclear Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.203-207
    • /
    • 1976
  • 질칼로이-4에 있어서 flow stress strain rate 의존성을 냉간가공 및 소둔된 시편에 대해 20$0^{\circ}C$-45$0^{\circ}C$ 온도 구간에서 응력이완 실험으로 조사하였다. 전체 실험온도에서 In-3-ln i 관계식은 $10^{-5}$-$10^{-3}$ sec$^{-1}$ strain rate의 구간에 걸쳐 선형관계를 보였다. 냉간 가공된 질칼로이 -4의 strain rate sensitivity, m값은 30$0^{\circ}C$에서 최소값을 보인 반면, 소둔된 시편의 경우 30$0^{\circ}C$와 45$0^{\circ}C$에서 최소값들을 보였다. 최소값의 m이 나타나는 온도는 가공시효값이 극대값을 보이는 온도와 일치한다는 사실이 확인되었다. m값의 감소는 활동자유전위들이 산소원자에 의해 pinning된 결과로 유발되는 가공 시효와 관련된 것으로 고려된다. 그리고 소둔된 시편이 45$0^{\circ}C$에서 가지는 최소 m값은 철 원자들로 인한 가공 시효에서 기인된 것으로 생각된다.

  • PDF

선박용 강제통풍 팬의 기어식 베인댐퍼 성능평가 (Development of Gear-Type Vane Dampers to Replace Link-Type Vane Dampers in Marine FD Fans)

  • 허남수;장성철;이경준
    • 한국산업융합학회 논문집
    • /
    • 제19권4호
    • /
    • pp.216-222
    • /
    • 2016
  • Thus, this study aimed to develop a gear-type vane damper in order to replace the link-type vane damper. To achieve this goal, the torque generated in a gear-type vane damper was analyzed, and a structural analysis was conducted. In addition, the fluid flow was analyzed according to the changes in the vane's angle, and experimental tests such as a dry-heat test and cold test were conducted considering the operating conditions of the vessels. Moreover, an appropriate actuator was selected for the developed gear-type vane damper, and studies on the reduction in the backlash due to the facing-pressure adjustment length and flow rate and leakage test due to the vane's angle were conducted.

고공환경 모사를 위한 초음속 디퓨저의 시동 특성 분석 (Starting Characteristics of Supersonic Exhaust Diffuser for Altitude Simulation Testing)

  • 김용욱;이정호;김상헌;오승협
    • 항공우주기술
    • /
    • 제11권2호
    • /
    • pp.117-121
    • /
    • 2012
  • 고공 환경 하에서 작동하는 우주발사체 상단 추진기관의 경우 지상에서 실제 작동 환경에 가까운 조건에서 연소시험을 수행하여 그 성능을 검증하게 된다. KSLV-I 상단 추진기관의 경우 원통형 디퓨저를 이용하여 고공환경 모사시험을 수행하였으며, 디퓨저의 설계 검증 및 시동특성을 확인하기 위해 축소형 디퓨저에 대한 비반응 유동시험 및 연소시험을 수행하였다. 본 논문에서는 축소형과 실물형 디퓨저에 대한 시험 결과를 제시하고 시동특성에 대해 분석하였다.

초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 설계 및 상온실험 (Design and Cold Test of Semi-Freejet High Altitude Environment Simulation Test Facility for High-Speed Vehicle)

  • 이성민;유이상;박진수;고영성;김선진;이정민
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.115-124
    • /
    • 2018
  • 본 연구에서는 초고속 비행체 고공환경 모사실험 설비에 대한 설계와 상온실험을 진행하였다. 시험 모델의 폐색율, 각도, 길이에 따른 변수실험을 진행하고, 변수에 따른 벽면압력변화를 확인하였다. 폐색율은 40%의 영역에서도 운용이 가능하며, 각도는 45도 이하의 크기에서 모델을 선정해야함을 확인하였다. 길이의 변수는 폐색율과 각도의 변수에 비하여 영향이 크지 않은 것을 확인하였다. 이를 통해서 초고속 비행체 시험설비에서 원뿔형 모델의 설계 변수에 따른 성능 데이터베이스를 확보하였다.