Abstract

Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

Keywords

References

  1. American Society for Testing and Materials (ASTM), 2001. Standard Practice for Calculating Thermal Transmission Properties Under Steady-state Conditions. ASTM C1045.
  2. American Society for Testing and Materials (ASTM), 2010. Standard Test Method for Steady-state Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. ASTM C518.
  3. Choi, S.W., Roh, J.U., Kim, M.S., Lee, W.I., 2011. Thermal analysis of two main CCS(cargo containment system) insulation box by using experimental thermal properties. J. Comput. Struct. Eng. Inst. Korea 24 (4), 429-438.
  4. Hyun, B.S., Kim, H.K., Choi, J.M., 2003. Study on MLI thermal modeling methods for satellite. In: The Korean Society for Aeronautical and Space Sciences 2003 Fall Conference, Kyung-Ju, Republic of Korea.
  5. Incropera, F.P., DeWitt, D.P., Bergman, T.L., Lavine, A.S., 2006. Fundamentals of Heat and Mass Transfer, 6th ed. John Willey & Sons, New York, pp. 571-577.
  6. Kim, D.G., Han, K.I., Choi, J.H., Lee, J.J., Kim, T.K., 2015. Study on a effective thermal conductivity of the CFRP composite structure by a simplified model. J. Comput. Fluids Eng. 20 (4), 63-69. https://doi.org/10.6112/kscfe.2015.20.4.063
  7. Lee, J.H., Lee, B.R., 1993. Determination of equivalent thermal conductivities of composite materials using homogenization technique. Trans. Korean Soc. Mech. Eng. 18 (5), 1245-1252. https://doi.org/10.22634/KSME.1994.18.5.1245
  8. Oh, H.Y., Song, K.O., Jeon, H.I., Cho, S.Y., 2016. Development of thermal performance tester for non-homogeneous insulation pannels installed vertically. Korean J. Air-Cond. Refrig. Eng. 28 (4), 153-157. https://doi.org/10.6110/KJACR.2016.28.4.153
  9. Park, H.C., Yang, H.S., 2009. LNG carrier's heat transfer analysis and make a BOR estimate equation. In: The Korean Society of Mechanical Engineers 2009 Fall Conference, Republic of Korea.
  10. Wang, J., Carson, J.K., North, M.F., Cleland, D.J., 2008. A new structural model of effective thermal conductivity for heterogeneous materials with co-continuous phases. Int. J. Heat Mass Transf. 51 (9), 2389-2397. https://doi.org/10.1016/j.ijheatmasstransfer.2007.08.028
  11. Yoo, D.C., Jang, H.I., Ann, H.J., Park, C.Y., Kim, H.G., Kim, Y.A., Choi, C.H., 2013. A prediction of equivalent U-value in composite timber-frame structure using statistical method. J. Korean Inst. Archit. Sustain. Environ. Build. Syst. 7 (4), 265-273.

Cited by

  1. Practical Prediction of the Boil-Off Rate of Independent-Type Storage Tanks vol.9, pp.1, 2018, https://doi.org/10.3390/jmse9010036