• Title/Summary/Keyword: Coincidence Analysis

Search Result 189, Processing Time 0.027 seconds

The Comparative Study between Leg Length Analysis and X-ray on Diagnosis of Pelvic Malpositions - according to Positions and Valuation Bases - (기능성 족지장단분석과 X-ray의 골반변위 진단의 비교 연구 - X-ray 촬영 자세 및 평가 기준에 따라 -)

  • Lee, Jung-Min;Koog, Gil-Ho;Choi, Bo-Mi;Jeong, Hyun-A;Hong, Seo-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.169-180
    • /
    • 2010
  • Objectives: This study was carried out to investigate the relationship of leg length analysis and X-ray finding according to positions and valuation bases on diagnosis of pelvic malpositions. Methods: Twenty-two people who get $33.09{\pm}10.73$ as average were evaluated by leg length analysis and X-ray findings. After measuring innominate measurement(IM), femur head line. distance between S2 and posterior superior iliac spine(PSIS). ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) and distance between off centering measurement and symphysis pubis, those were analyzed. Results: 1. In assessment of posterior rotation malposition ilium(PI), it was showed the best coincidence between leg length analysis and X-ray analyzed by 1M in supine position(11 cases, 50.5%). 2. In assessment of inflare, coincidence index between leg length analysis and X-ray were not good($4.00{\pm}3.03$ cases, $18.15{\pm}13.82%$). And leg length analysis were not sensitive. 3. On the whole, coincidence index between leg length analysis and X-ray were not good(best: 1 case, 45.5%; worst: 11 cases, 50.0%). Conclusions: Results form this investigation showed the relationship of leg length analysis and X-ray according 10 positions and valuation bases on diagnosis of pelvic malpositions. This results are expected to contribute to establish method of assessment in diagnosis of pelvic malpositions.

  • PDF

Effect of Silicon on Intergranular Corrosion Resistance of Ti-stabilized 11 wt% Cr Ferritic Stainless Steels (11 wt% 크롬이 함유된 Ti 첨가 페라이트스테인리스강의 입계부식에 미치는 규소의 영향)

  • Hyun, Youngmin;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.265-273
    • /
    • 2013
  • Ti-stabilized 11 wt% Cr ferritic stainless steels (FSSs) for automotive exhaust systems have been experienced intergranular corrosion (IC) in some heat-affected zone (HAZ). The effects of sensitizing heat-treatment and silicon on IC were studied. Time-Temperature-Sensitization (TTS) curves showed that sensitization to IC was observed at the steels heat-treated at the temperature lower than $650^{\circ}C$ and that silicon improved IC resistance. The sensitization was explained by chromium depletion theory, where chromium is depleted by precipitation of chromium carbide during sensitizing heat-treatment. It was confirmed with the results from the analysis of precipitates as well as the thermodynamical prediction of stable phases. In addition, the role of silicon on IC was explained with the stabilization of grain boundary. In other words, silicon promoted the formation of the grain boundaries with low energy where precipitation was suppressed and consequently, the formation of Cr-depleted zone was retarded. The effect of silicon on the formation of grain boundaries with low energy was proved by the analysis of coincidence site lattice (CSL) grain boundary, which is a typical grain boundary with low energy.

Three dimensional analysis of Korean dentogingival complex (한국인 치아치은 집합체구조의 삼차원적인 분석)

  • Park, Yeong-Suk;Lee, Seung-Pyo;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.199-206
    • /
    • 2008
  • Purpose: Variation in the morphology of gingival papilla may be determined by the shape and position of anatomic crown as well as contact area and embrasure form of individual teeth. However, periodontal biotype classification is regarded to be subjective because of the lack of definite criteria. In this study, we defined the objective parameters which constitute the periodontal biotype and measured their relationship. Materials and Methods: 109 of dental casts were prepared using three dimensional scanner and specialized reconstruction software, then acquiredvirtual models were sent to the 20 professional dentists to define the specific periodontal biotypes. Several parameters around periodontal structures were measured from the virtual models; facial surface area of the anterior tooth (AT), anterior papillary area (AP), proportion of the dento-papillary complex, clinical papillary length (PL), and clinical papillary angle (PA). Statistical analysis was performed to confirm the relationship among parameters. Results: Coincidence rate of periodontal biotype within observers was $63.77{\pm}16.05%$. Coincidence rate between observers was $76.15{\pm}16.43%$. Among the parameters measured, PL showed the most positive correlations and PA presented the most negative correlations. The parameter of the AP and PL of six maxillary anterior teeth showed significant correlation coefficient. Conclusion: Anterior papillary area and clinical papillary length would be objective parameters for determining the consistent periodontal biotypes.

Proton Irradiated Cz-Si by the Coincidence Doppler Broadening Positron Annihilation Spectroscopy (동시계수 양전자 소멸 측정에 의한 양성자 조사된 Si 구조 특성)

  • Lee, K.H.;Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.367-373
    • /
    • 2011
  • It is described that the proton beam induces micro defects and electronic deep levels in Cz single crystal silicon. Enhance signal-to-noise ratio, Coincidence Doppler Broadening Positron Annihilation Spectroscopy has been applied to study of characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The samples were exposed by 4.0 MeV proton beams ranging from 0 to ${\sim}10^{14}$ ptls. The S-parameter values were increased as increasing the irradiated proton beam, that indicated the defects generate more.

Optimization of Acquisition Time of Beta-Gamma Coincidence Counting System for Radioxenon Measurement (방사성제논 탐지를 위한 베타-감마 동시 계측시스템의 측정시간 최적화)

  • Byun, Jong-In;Park, Hong-Mo;Choi, Hee-Yeoul;Song, Myeong-Han;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.181-186
    • /
    • 2015
  • Measurement of xenon radioisotopes from nuclear fission is a key element for monitoring underground nuclear weapon tests. $^{131m}Xe$, $^{133}Xe$, $^{133}mXe$ and $^{135}Xe$ in the air can be detected via low background systems such as a beta-gamma coincidence counting system. Radioxenon monitoring is performed through air sampling, xenon extraction, measurement and spectrum analysis. The minimum detectable concentration of $^{135}Xe$ can be significantly variable depending on the sampling time, extraction time and data acquisition time due to its short half-life. In order to optimize the acquisition time with respect to certain experimental parameters such as sampling and xenon extraction, theoretical approach and experiment using SAUNA system were performed to determine the time to minimize the minimum detectable concentration, which the results were discussed.

Estimation of Equivalent Viscous Damping of Structure with Base Isolation Devices (면진장치를 가지는 구조물의 등가점성감쇠비 산정)

  • 김태호;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.359-366
    • /
    • 2002
  • Direct Integration method(D.I) and Mode Superposition method(M.S) are used widely in dynamic analysis method for structure with isolation devices. D.I is used firstly because it is consider to nonlinearity of isolation device. M.S is applied in elastic region, but it is difficult to apply M.S because coincidence with othogonality condition in the case of adding the damping of isolation device. In this study, the method for calculation of damping ratio of isolated structure is proposed, and proposed method is verified with analysis for example structure.

  • PDF

The Security Plan of Matching Accuracy between Digital Map and Cadastral Map (수치지도와 지적도간의 정합정축도 확보방안)

  • 강준묵;윤희천;엄대용;강영미
    • Spatial Information Research
    • /
    • v.11 no.4
    • /
    • pp.391-407
    • /
    • 2003
  • Recently, a lot of interests are commanding in link practical use of country information and cadastral information for management of efficient country resource and administration of land. As map information, a lot of interests are commanding in construction of synthetic informations system including digital map and cadastral map. In this study, achieves analysis about non-coincidence causes of digital map and cadastral map, and achieve investigation about representative algorithm that is used in conversion of map for correct overlay between two map and opes overlay plan. Also, presented plan that can ready fetters for integration database construction of digital map and cadastral map by achieving study about matching security plan between map and plan elevation of the quality.

  • PDF

Analysis of Cadastral Non-Coincidence Area by GSIS (GSIS에 의한 지적 불부합지의 해석)

  • Oh, Chang-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.1 s.19
    • /
    • pp.77-82
    • /
    • 2002
  • This study try to attempt to manage on-line system of land cadastral by computing land registration information, for application to computerized cadastral work through Geo-Spatial Information System. And also, in order to consult D/B of cadastral information, cadastral non-coincidence area uncapable to D/B when land-survey, taking advantage of GSIS drawing made by the present condition drawing and the aerial photograph survey by general survey, makes actual cadastral control point by some selected investigators. And so, it can be compared and analysed by the result of the present survey and, through the interpretation of the relatives, it aims to improve the precision of survey technique in consulting cadastral information D/B in the future.

  • PDF

Detemination of Dynamic Stress Intensity Factor of Brittle Materials under Impact Loading (충격하중을 받는 취성재료의 동적응력확대계수 결정)

  • 이억섭;이찬석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.381-386
    • /
    • 1993
  • This paper describes the dynamic fracture behavior of brittle materials under impact loading by using INSAMCR program with instrumented charpy test machine. To calculate the Dynamic Stress Intensity Factor The finite element analysis methods program, INSAMCR, was used. Dynamic fracture characteristic was researched to verify a relationship between Dynamic Stress Intensity Factor and crack tip propagation velocity in WC-6%Co. The relationship between Dynamic Stress Intensity Factor and crack tip velocity revealed typical .GAMMA. shape. INSAMCR was run to verify experimental results in WC-6%Co and shows a good coincidence.

  • PDF

A Development of Evaluation Indicators for Information Security by means of the Coincidence Analysis (부합성 분석을 통한 정보보안 평가지표 도출)

  • Lee, Yeong-Kyu;Kim, Sang-Hoon
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.185-190
    • /
    • 2008
  • 정보화의 진전과 더불어 삶의 편이성은 증대되고 있으나 개인과 조직은 물론이고 국가에 이르기까지 정보보안 사고로 피해와 고통 또한 증대되고 있는 실정이다. 이러한 사고로 인한 피해를 사전에 예방하거나 사후 손실을 최소화하기 위해서는 적절한 관리가 필요하며 이를 위해서는 무엇보다 실용적인 정보보안 평가지표의 개발이 필요하다. 본 연구에서는 정보보안을 대표하는 문헌을 참조하여 평가지표를 도출하고, 일련의 부합성 분석을 통해 보다 실용적인 정보보안 평가지표를 도출하여 제시하고자 한다.

  • PDF