• 제목/요약/키워드: Coherent imaging

검색결과 55건 처리시간 0.037초

Structure of Ni and NiO Nanoparticles Observed by X-ray Coherent Diffraction Imaging

  • Kim, Chan;Kim, Yoon-Hee;Hamh, Sun-Young;Son, Jun-Gon;Khakurel, Krishna Prasad;Iqbal, Mazhar;Noh, Do-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.542-543
    • /
    • 2012
  • Coherent diffraction imaging (CDI) method using hard x-ray at 5.46 keV was applied to study assembly of Ni and Ni oxide nano structures formed on a Si3N4 membrane. Density distribution of Ni nano-particles was obtained quantitatively with about 15 nm lateral resolution by reconstructing images from the speckle diffraction pattern. In addition, reconstructed images of nickel oxide particles indicated that Ni atoms diffuse out during the oxidation process leaving pores inside the nickel oxide crust. Furthermore, we recognize that really weak phase object, less than 5 nm thickness of Ni residues, can be reconstructed due to the reference particles. We achieved quantitative information of nanometer sized materials and demonstrate the effect of reference particles by using hard x-ray coherent diffractive imaging method.

  • PDF

TEM 관련 이론해설 (3): 영상 형성이론과 회절이론 (Theory of Imaging And Diffraction)

  • 이확주
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.169-178
    • /
    • 2003
  • 영상이론과 회절 이론을 같은 비중으로 다루고 이들과의 관계를 나타내는 wave optics 이론을 소개하였다. 결맞는 파동 이론과 결 안맞는 파동이론 사이의 차이를 나타내고 Abbe이론과 여러 가지 phase contrast 이론들을 small angle 근사로 접근하였다. 마지막으로 다중 성분 시스템에 대한 파동 광학의 수학적인 방법의 적용을 소개하였다.

Label-Free Molecular Imaging of Living Cells

  • Fujita, Katsumasa;Smith, Nicholas Isaac
    • Molecules and Cells
    • /
    • 제26권6호
    • /
    • pp.530-535
    • /
    • 2008
  • Optical signals based on Raman scattering, coherent anti-Stokes Raman scattering (CARS), and harmonic generation can be used to image biological molecules in living cells without labeling. Both Raman scattering and CARS signals can be used to detect frequencies of molecular vibrations and to obtain the molecular distributions in samples. Second-harmonic optical signals can also be generated in structured arrays of noncentrosymmetric molecules and can be used to detect structured aggregates of proteins, such as, collagen, myosin and tubulin. Since labeling techniques using chemical and biological reactions may cause undesirable changes in the sample, label-free molecular imaging techniques are essential for observation of living samples.

The Optical Design of Miniaturized Microscope Objective for CARS Imaging Catheter with Fiber Bundle

  • Rim, Cheon-Seog
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.424-430
    • /
    • 2010
  • In coherent anti-Stokes Raman scattering (CARS) microscopy reported until now, conventional microscope objectives are used, so that they are limited for introduction into a living body. Gradient-index (GRIN) rod lenses might be a solution for miniaturized microscope objectives for in-vivo CARS microscopy. However, due to the inherent large amount of chromatic aberration, GRIN rod lenses cannot be utilized for this purpose. CARS imaging catheter, composed of miniaturized microscope objective and fiber bundle, can be introduced into a living body for minimally invasive diagnosis. In order to design the catheter, we have to first investigate design requirements. And then, the optical design is processed with design strategies and intensive computing power to achieve the design requirements. We report the miniaturized objective lens system with diffraction-limited performance and completely corrected chromatic aberrations for an in-vivo CARS imaging catheter.

EUV 펠리클 투과도에 따른 이미지 전사 특성 분석 (Imaging Performance of the Dependence of EUV Pellicle Transmittance)

  • 우동곤;김정환;김정식;홍성철;안진호
    • 반도체디스플레이기술학회지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2016
  • Extreme Ultraviolet Lithography (EUVL) is the most promising technique in the field of Next Generation Lithography (NGL) expected to be used in the 1x-nm node for High Volume Manufacturing (HVM). But there exits remaining challenges for proper defect control of EUV mask. It was considered development of EUV pellicle for protecting the EUV mask has many obstacles due to high extinction coefficient of EUV wavelength. Recently researchers in the industry of semiconductor argue about the necessity of EUV pellicle and make effort to achieve it. In this paper, we investigated that the relationship between imaging performance and transmittance of EUV pellicle quantitatively. We made in-house EUV pellicle and analyzed its imaging performance of the dependence of pellicle transmittance using Coherent Scattering Microscopy(CSM). The imaging performance of EUV mask with pellicle is affected by its transmittance and we found that the performance of EUV mask improved with higher transmittance pellicle.

공간영역에서 코히어런트 단층촬영 기법을 이용한 Born 근사하에 유전체 기둥의 영상제현 (Image Reconstruction of Dielectric Cylinder Under Born Approximation Using a Coherent Tomographic Scheme in the Spatial Domain)

  • 서경환;김상기;김세윤;라정웅
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1327-1335
    • /
    • 1990
  • In this paper, using the principle of duality between the spatial and spectral domain, we proposed a new microwave imaging technique of a coherent tomographic formulation in the spatial domain and reconstructed the image of dielectric cylinder through simulation and experiment. The numerical and experimental results for the variety o object size, relative dielectric constant have shown the limitation of Born approximation to be used and the effect of retrieved images for various signal bandwidth.

  • PDF

3차원 Confocal Imaging과 생체 영상 분석 (Three Dimensional Confocal Imaging and Biomedical Image Analysis)

  • 이임걸
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.257-261
    • /
    • 1995
  • Confocal laser scanning microscopy (CLSM)는 기존의 coherent or incoherent microscopic imaging 보다 횡축 방향 (lateral direction)으로 고해상도를 가지며, 층과 층 사이를 구분하는 광축 방향 (axial direction)의 optical sectioning에 의해 샘플의 3D 구조를 고해상도로 영상화함으로써 3D 구조 및 생체 기능 분석을 가능하게 해 준다. 본 논문에서는 CLSM에 의한 3D 영상화 원리와 촛점면 부근에서 얻어지는 광세기 분포, 얻어진 2D slice 영상의 시각화 및 응용에 대해 논의된다.

  • PDF