• Title/Summary/Keyword: Coefficient of Concordance

Search Result 48, Processing Time 0.023 seconds

Seroprevalence of Brucellosis among Risk Population in Gyeongsangbuk-do, 2006 (경상북도 거주 고위험군에서 브루셀라 감염에 관한 혈청 역학적 연구)

  • Lee, Kwan;Park, Woo-Won;Kim, Sung-Hwan;Lee, Do-Young;Park, Mi-Yeoun;Hur, Young-Ju;Lim, Hyun-Sul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • Objectives : Cases of human brucellosis in Korea have recently increased due to the increasing incidence of bovine brucellosis. The authors conducted this study to elucidate the status of brucellosis through seroepidemiologic study. Methods : We selected our study population from a high risk group. We conducted a questionnaire survey and obtained blood samples to determine the seroprevalence of brucellosis antibodies for 10 days in February, 2005. The titers of brucellosis were measured by the combination of standard tube agglutination test (STA) and enzyme-linked immunosorbent assay (ELISA) test. Results : Our study subjects comprised 1,075 cases: 971 livestock workers, 51 veterinarians, and 53 artificial inseminators. In the STA test, 27 cases (2.5%) had titers of greater than or equal to 1:20. Of 1,068 cases (7 cases were excluded due to previous brucellosis), 7 cases of brucellosis were diagnosed with titers of 1:160, giving a seroprevalence of brucellosis of 0.66%. The seroprevalence in the male group was 0.95%, and that of livestock workers, veterinarians, and artificial inseminators was 0.52%, 4.17%, and 0.00%, respectively. The Spearman's correlation coefficient between the positive rate of bovine brucellosis per capita and household and human brucellosis was 0.806 and 0.744, respectively. The concordance rate between the Korea National Institute of Health and the Gyeongsangbuk-do Institute of Health and Environment by the STA and ELISA tests was 94.7% and 100.0%, respectively. Conclusions : The study results indicated in higher seroprevalence rate among veterinarians than among livestock workers and artificial inseminators. Because veterinarians may be exposed to this high risk, effective working guidelines for veterinarians to guard against brucellosis must be developed. Moreover, more extensive epidemiologic research for laboratory workers and meat handlers is needed.

The Development of Quality Evaluation Index of Vinegar Beverage - Using Delphi Method and Analytical Hierarchical Process(AHP) - (식초 음료의 품질평가지표 개발에 관한 연구 - 델파이 및 AHP 기법을 중심으로 -)

  • Kim, Jihyung;Ko, Jae-Youn;Yoo, Eunyi
    • Culinary science and hospitality research
    • /
    • v.22 no.4
    • /
    • pp.288-301
    • /
    • 2016
  • This paper employed typology and stratification as key elements to estimate quality evaluation of vinegar drink through Delphi and AHP(analytical hierarchical process) method to contribute the market expansion of the vinegar drink as a health drink. Through literature research and brainstorming with professionals, the first round of Delphi method was conducted with the open-ended questions including five upper concepts, i.e. 'ingredients', 'production method', 'product characteristics', 'functions' and 'packaging design'. Original study had 50 lower concepts as a result of the first round and added 'marketing' as an additional upper concept. The second and third round of Delphi method have been conducted with closed-ended questions based on the 50 lower concepts resulted from the first round. To seek concordant objectivity among the answers from the survey, the study used Kendall's W coefficient of concordance. 11 items were removed while 16 items were removed at the third round leaving 23 items through second round of Delphi method. For the final round, this study utilized the Pairwise Comparison Method to figure out the relative importance of the 23 items for the prioritization. Finally, current study formulated the final items which should be considered as an important factor in the quality evaluation of vinegar drink.

Assessment of Two Clinical Prediction Models for a Pulmonary Embolism in Patients with a Suspected Pulmonary Embolism (폐색전증이 의심된 환자에서 두 가지 폐색전증 진단 예측 모형의 평가)

  • Park, Jae Seok;Choi, Won-Il;Min, Bo Ram;Park, Jie Hae;Chae, Jin Nyeong;Jeon, Young June;Yu, Ho Jung;Kim, Ji-Young;Kim, Gyoung-Ju;Ko, Sung-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.4
    • /
    • pp.266-271
    • /
    • 2008
  • Background: Estimation of the probability of a patient having an acute pulmonary embolism (PE) for patients with a suspected PE are well established in North America and Europe. However, an assessment of the prediction rules for a PE has not been clearly defined in Korea. The aim of this study is to assess the prediction rules for patients with a suspected PE in Korea. Methods: We performed a retrospective study of 210 inpatients or patients that visited the emergency ward with a suspected PE where computed tomography pulmonary angiography was performed at a single institution between January 2005 and March 2007. Simplified Wells rules and revised Geneva rules were used to estimate the clinical probability of a PE based on information from medical records. Results: Of the 210 patients with a suspected PE, 49 (19.5%) patients had an actual diagnosis of a PE. The proportion of patients classified by Wells rules and the Geneva rules had a low probability of 1% and 21%, an intermediate probability of 62.5% and 76.2%, and a high probability of 33.8% and 2.8%, respectively. The prevalence of PE patients with a low, intermediate and high probability categorized by the Wells rules and Geneva rules was 100% and 4.5% in the low range, 18.2% and 22.5% in the intermediate range, and 19.7% and 50% in the high range, respectively. Receiver operating characteristic curve analysis showed that the revised Geneva rules had a higher accuracy than the Wells rules in terms of detecting PE. Concordance between the two prediction rules was poor ($\kappa$ coefficient=0.06). Conclusion: In the present study, the two prediction rules had a different predictive accuracy for pulmonary embolisms. Applying the revised Geneva rules to inpatients and emergency ward patients suspected of having PE may allow a more effective diagnostic process than the use of the Wells rules.

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Interobserver Reproducibility of Segmental Scoring of $^{99m}Tc$-MIBI Myocardial SPECT ($^{99m}Tc$-MIBI 심근 SPECT의 분절 육안 분석시 판독자간의 일치도)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Lee, Kyung-Han;Kim, Jong-Ho;Shon, Kyung-Soo;Cho, Sung-Wook;Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul;Seo, Jeong-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.317-325
    • /
    • 1994
  • The accuracy of dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial imaging for detection of ischemia depends on reproducible image interpretation. To evaluate the reproducibility of visual assessment, agreement in interpretation among two independent observers, blind-ed to clinical data, was evaluated in SPECT images of 131 patients (94 males, 38 females; mean age $58{\pm}7yr$) with suspected coronary artery disease who underwent both dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial SPECT and coronary angiography. The left ventricle was divided into twenty-nine segments in stress and rest SPECT images and each segment was visually graded according to a five-point scale (segmental score : 0=normal, 1=equivocal, 2=mild decrease, 3=severe decrease and 4=absent uptake). Overall concordance of segmental scoring between the two observers was 80%. The Pear-son's correlation coefficient (r) of the segmental scores for stress and rest images were 0.67 and 0.65, respectively, while the difference in score between the two images showed a correlation of 0.45 (all p<0.001). Agreement between two observers in final SPECT diagnosis as absence or presence of disease was 93%. The degree of agreement in segmental scoring showed no difference between patients with or without agreement as to the presence of disease. Therefore it appeared that cases with inconcordant diagnosis between the 2 observers were mainly due to a difference in individual threshold for interpretating the significance of a particular decreased uptake area rather than to a difference in perceiving the degree of the hypoactivity Thus, establishment of individual optimum thresholds in visual interpretation of myocardial SPECT may be helpful to improve reproducibility and accuracy of scan diagnosis.

  • PDF

Comparative Volume Measuring Methods According to the Tumor Characters in PET/CT (PET/CT 검사에서 종양의 특성에 따른 체적 측정 방법 비교)

  • Choi, Yong Hoon;Ban, Yung Gak;Oh, Shin Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose Recent retrospective studies are being actively conducted to analyze the survival of patients with SUVmax, MTV, TLG, such as information from a variety of PET originating. However, there is no clear way is difficult to accurately measure the volume of the tumor may be the difference between the caster is raised. In this study, to evaluate compare the volume measuring methods according to the characteristics of the tumor. Materials and Methods 18F-saline to fill the NEMA IEC Body Phantom insert the volume of balance and imbalance in phantom were acquired to the Biograph truepoint 40 (Siemens medical system, Germany) PET/CT scanner. The ratio of the volume and Background was acquired as 3.0, 5.0, 8.0, 18, 40. Clinical patients were randomly selected 120 people in staging patients with cancer of the digestive system from the year 2010 until the year 2014. Measurement methods were used a 40% threshold, 50% threshold and gradient segmentation technique, i.e. PET EDGE. Five years of experience of the two radio-technologist and one doctor was measured by repeated three times. Analysis methods were Intraclass correlation coefficient and Pearson correlation. Results In Phantoms, the 40% threshold method gave the best concordance between measured and actual volumes (r = 0.992, 0.997). In clinical patient outcome agreement between observers EDGE it is as high as 0.999 (CI: 0.998-0.999). And there were no statistical significance of the difference between the measurements (P = 0.620). 40% threshold method showed the best correlation between the measurements (r = 0.953). Increasing the ratio of tumor to background decreased the influence of a measuring method. Conclusion How to measure volume of the tumor in the patient was clinically most useful is 50% and the lowest impact on the characteristics of the tumor. Therefore, to reduce the background of the patients in PET/CT scan, it should be required research and effort.

  • PDF

A Study of Esthetic Facial Profile Preference In Korean (한국인의 연조직측모 선호경향에 대한 연구)

  • Choi, Jun-Gyu;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.327-342
    • /
    • 2002
  • Soft tissue profile is a critical area of interest in the development of an orthodontic treatment and diagnosis. The purpose of this study was to determine the facial profile preference of diversified group and to investigate the relationship between most Preferred facial Profile and existing soft tissue reference lines. A survey instrument of constructed facial silhouettes was evaluated by 894 lay person. The silhouettes had varied nose, lips, chin and soft tissue subnasale point. Seven sets of facial type were computer-generated by an orthodontist to represent distinct facial types. The varied facial profiles were graded on the basis of most preferred to least preferred. Every facial profile were measured by soft tissue reference lines(Ricketts E-line, Burstone B-line) to observe the most preferred facial profile. The results as follows: 1. In reliability test, the childhood group showed lower value than other groups, which means that this group has no concern on facial profile preference. 2. It appears that sexual and age difference made no significant difference in selecting the profile 3. An agreement to least preferred facial profile was higher than an agreement to most preferred facial profile. 4. Coefficient of concordance (Kendall W) was higher in the twentieth group. It means that a profile preference of the twentieth is distinct. 5. A lip protrusion (to Ricketts E-line and Burstone B-line) of most preferred facial profile was similar to measurements of previous study that investigate skeletal and soft tissue of esthetic facial profile of young Korean. So these reference lines can be used valuably in clinics. 6. Profile of excessive lip protrusion or retrusion to E-line & B-line was least preferred. 7. Most preferred profile of all respondents group was straight profile. Profile that showing convex profile was not pre(erred and the least preferred profile was concave profile.

Validation of initial nutrition screening tool for hospitalized patients (입원 환자용 초기 영양검색도구의 타당도 검증)

  • Kim, Hye-Suk;Lee, Seonheui;Kim, Hyesook;Kwon, Oran
    • Journal of Nutrition and Health
    • /
    • v.52 no.4
    • /
    • pp.332-341
    • /
    • 2019
  • Purpose: Poor nutrition in hospitalized patients is closely linked to an increased risk of infection, which can result in complications affecting mortality, as well as increased length of hospital stay and hospital costs. Therefore, adequate nutritional support is essential to manage the nutritional risk status of patients. Nutritional support needs to be preceded by nutrition screening, in which accuracy is crucial, particularly for the initial screening. To perform initial nutrition screening of hospitalized patients, we used the Catholic Kwandong University (CKU) Nutritional Risk Screening (CKUNRS) tool, originally developed at CKU Hospital. To validate CKUNRS against the Patient-Generated Subjective Global Assessment (PG-SGA) tool, which is considered the gold standard for nutritional risk screening, results from both tools were compared. Methods: Nutritional status was evaluated in 686 adult patients admitted to CKU Hospital from May 1 to July 31, 2018 using both CKUNRS and PG-SGA. Collected data were analyzed, and the results compared, to validate CKUNRS as a nutrition screening tool. Results: The comparison of CKUNRS and PG-SGA revealed that the prevalence of nutritional risk on admission was 15.6% (n = 107) with CKUNRS and 44.6% (n = 306) with PG-SGA. The sensitivity and specificity of CKUNRS to evaluate nutritional risk status were 98.7% (96.8 ~ 99.5) and 33.3% (28.1 ~ 39.0), respectively. Thus, the sensitivity was higher, but the specificity lower compared with PG-SGA. Cohen's kappa coefficient was 0.34, indicating valid agreement between the two tools. Conclusion: This study found concordance between CKUNRS and PG-SGA. However, the prevalence of nutritional risk in hospitalized patients was higher when determined by CKUNRS, compared with that by PG-SGA. Accordingly, CKUNRS needs further modification and improvement in terms of screening criteria to promote more effective nutritional support for patients who have been admitted for inpatient care.