• Title/Summary/Keyword: Coefficient Matrix

Search Result 844, Processing Time 0.029 seconds

Deriving Key Risk Sub-Clauses which the Engineer of FIDIC Red Book Shall Agree or Determine according to Sub-Clause 3.7 -based on FIDIC Conditions of Contract for Construction, Second Edition 2017- (FIDIC Red Book의 Engineer가 합의 또는 결정해야할 핵심 리스크 세부조항 도출 -FIDIC Red Book 2017년 개정판 기준으로-)

  • Jei, Jae Yong;Hong, Seong Yeoll;Seo, Sung Chul;Park, Hyung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.239-247
    • /
    • 2023
  • The FIDIC Red Book is an international standard contract condition in which the Employer designs and the Contractor performs the construction. The Engineer of FIDIC Red Book shall agree or determine any matter or Claim in accordance with Sub-Clause 3.7 neutrally, not as an agent of the Employer. This study aimed to derive Key Risk Sub-Clauses out of 49 Sub-Clauses that the Engineer of FIDIC Red Book recently revised in 18 years shall agree or determine according to Sub-Clause 3.7 using the Delphi method. A panel of 35 experts with more than 10 years of experience and expertise in international construction contracts was formed, and through total three Delphi surveys, errors and biases were prevented in the judgment process to improve reliability. As for the research method, 49 Sub-Clauses that engineers shall agree on or determine according to Sub-Clause 3.7 of the FIDIC Red Book were investigated through the analysis of contract conditions. In order to evaluate the probability and impact of contractual risk for each 49 Sub-Clause, the Delphi survey conducted repeatedly a closed-type survey three times on a Likert 10-point scale. The results of the first Delphi survey were delivered during the second survey, and the results of the second survey were delivered to the third survey, which was re-evaluated in the direction of increasing the consensus of experts' opinions. The reliability of the Delphi 3rd survey results was verified with the COV value of the coefficient of variation. The PI Risk Matrix was applied to the average value of risk probability and impact of each of the 49 Sub-Clauses and finally, 9 Key Risk Sub-Clauses that fell within the extreme risk range were derived.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Clean Separation of Difluoromonochloromethane(R22)/Hexafluoropropylene(HFP) by Using Liquid-Supported Membrane(BMIBF4/PVDF) (고정화 액막(BMIBF4/PVDF)에 의한 디플루오로-클오로메탄과 헥사플루오로프로필렌의 청정분리)

  • Choi, Pyoung-Ho;Kim, Chul-Ung;Kim, Beom-Sik;Lee, Jung-Min;Koo, Kee-Kahb
    • Clean Technology
    • /
    • v.9 no.4
    • /
    • pp.169-177
    • /
    • 2003
  • In order to develope a clean technology by liquid-supported membrane of ionic liquid/PVDF, the solubility of R22 and HFP gases using BMIBF4 as ionic liquid were measured at temperatures from 0 to $30^{\circ}C$, at total pressures up to 4 bars. The solubility of R22 in this ionic liquid was shown a rapid increasing tendency with increases of pressure and decreases of temperature, respectively, whereas the solubility of HFP was showed only a little in the same conditions. Based on these results, liquid-supported membranes of ionic liquid/PVDF were prepared by variables of the deposition amount of ionic liquid in polymer matrix, PVDF and were applied to the separation of fluoro-gases(R22, HFP) including $N_2$ gas. The permeability of R22 was rapidly increased by depending on the deposition amounts of ionic liquid, whereas both of HFP and $N_2$ were just showed so little. Especially, the diffusivity coefficient and solubility parameter of R22 were increased by lower operating temperatures and increased deposition amount of ionic liquid in 1iquid membrane. In conclusion, the selectivity of R22 against HFP was changed to 10-45 times depending on both of operating temperatures and the deposition amount of ionic liquid in BMIBF4/PVDF liquid membrane.

  • PDF

Study for Residue Analysis of Pinoxaden in Agricultural Commodities

  • Kim, Ji Young;Yoon, Eun Kyung;Kim, Jong Soo;Seong, Nu Ri;Yun, Sang Soon;Jung, Yong Hyun;Oh, Jae Ho;Kim, Hyochin
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.4
    • /
    • pp.321-331
    • /
    • 2019
  • BACKGROUND: Pinoxaden is the phenylpyrazoline herbicide developed by Syngenta Crop Protection, Inc. and marketed on 2006. The maximum residue levels for wheat and barley were set by import tolerance. Thus, Ministry of Food and Drug Safety (MFDS) official analytical method determining Pinoxaden residue was necessary in various food matrixes. Satisfaction of international guideline of CODEX (Codex Alimentarius Commission CAC/GL 40) and National Institute of Food and Drug Safety Evaluation-MFDS (2017) are additional pre-requirements for analytical method. In this study, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was investigated to analyze residue of Pinoxaden (M4), which is defined as pesticide residue in Korea, in foods. METHODS AND RESULTS: Pinoxaden (M4) was extracted followed by acid digestion (2hr reflux with 1N HCl) and pH adjusting (pH 4-5 with 3% ammonium solution). To remove oil, additional clean-up step with hexane saturated with acetonitrile was required to high oil contained sample before purification. HLB cartridge and nylon syringe filter were used for purification. Then, samples were analyzed by LC-MS/MS using reserve phase column C18. Five agricultural group representative commodities (mandarin, potato, soybean, hulled rice, and red pepper) were used to verify the method in this study. The liner matrix-matched calibration curves were confirmed with coefficient of determination (r2) > 0.99 at calibration range 0.002-0.2 mg/kg. The limits of detection and quantitation were 0.004 and 0.01 mg/kg, respectively, which were suitable to apply Positive List System (PLS). Mean average accuracies of pinoxaden (M4) were shown to be 74.0-105.7%. The precision of pinoxaden and its metabolites were also shown less than 14.5% for all five samples. CONCLUSION: The method investigated in this study was suitable to CODEX (CAC/GL 40) and National Institute of Food and Drug Safety Evaluation-MFDS (2017) guideline for residue analysis. Thus, this method can be useful for determining the residue in various food matrixes in routine analysis.

Epoxy/BaTiO3 (SrTiO3) composite films and pastes for high dielectric constant and low tolerance embedded capacitors fabrication in organic substrates

  • Paik Kyung-Wook;Hyun Jin-Gul;Lee Sangyong;Jang Kyung-Woon
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2005.09a
    • /
    • pp.201-212
    • /
    • 2005
  • [ $Epoxy/BaTiO_3$ ] composite embedded capacitor films (ECFs) were newly designed fur high dielectric constant and low tolerance (less than ${\pm}15\%$) embedded capacitor fabrication for organic substrates. In terms of material formulation, ECFs are composed of specially formulated epoxy resin and latent curing agent, and in terms of coating process, a comma roll coating method is used for uniform film thickness in large area. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ composite ECF is measured with MIM capacitor at 100 kHz using LCR meter. Dielectric constant of $BaTiO_3$ ECF is bigger than that of $SrTiO_3$ ECF, and it is due to difference of permittivity of $BaTiO_3\;and\;SrTiO_3$ particles. Dielectric constant of $BaTiO_3\;&\;SrTiO_3$ ECF in high frequency range $(0.5\~10GHz)$ is measured using cavity resonance method. In order to estimate dielectric constant, the reflection coefficient is measured with a network analyzer. Dielectric constant is calculated by observing the frequencies of the resonant cavity modes. About both powders, calculated dielectric constants in this frequency range are about 3/4 of the dielectric constants at 1 MHz. This difference is due to the decrease of the dielectric constant of epoxy matrix. For $BaTiO_3$ ECF, there is the dielectric relaxation at $5\~9GHz$. It is due to changing of polarization mode of $BaTiO_3$ powder. In the case of $SrTiO_3$ ECF, there is no relaxation up to 10GHz. Alternative material for embedded capacitor fabrication is $epoxy/BaTiO_3$ composite embedded capacitor paste (ECP). It uses similar materials formulation like ECF and a screen printing method for film coating. The screen printing method has the advantage of forming capacitor partially in desired part. But the screen printing makes surface irregularity during mask peel-off, Surface flatness is significantly improved by adding some additives and by applying pressure during curing. As a result, dielectric layer with improved thickness uniformity is successfully demonstrated. Using $epoxy/BaTiO_3$ composite ECP, dielectric constant of 63 and specific capacitance of 5.1nF/cm2 were achieved.

  • PDF

Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링)

  • Lee, Young-Jun;Choi, Jeong-Heui;Chung, Hyung Suk;Lee, Han Sol;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.166-174
    • /
    • 2016
  • BACKGROUND: The current study developed a monitoring method of 6 veterinary antibiotics (amoxicillin, ampicillin, enrofloxacin, tetracycline, chlortetracycline, oxytetracycline) in agricultural soils using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization mode.METHODS AND RESULTS: Sample preparation was carried out using acidic acetonitrile and citrate salts followed by purification with dispersive solid phase extraction (d-SPE). Separation on Eclipse Plus C18 column was conducted in gradient of the mobile phase, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations expressed as the coefficient of determination was good with R2≥0.9900. The limit of quantifications (LOQs) ranged from 0.5 to 10 μg/kg for all analytes. Analysis of 51 agricultural soil samples taken in the Republic of Korea revealed concentrations less than 1.9 μg/kg for enrofloxacin, 75.5 μg/kg for chlortetracycline.CONCLUSION: The method was successfully applied to monitor 6 veterinary antibiotics from 51 field incurred agricultural soil samples in 17 provincial areas throughout the Republic of Korea. The developed method was simple, easy, and versatile and can be used for monitoring various veterinary antibiotics in soil.

Determination of Cd(II) after Preconcentration onto Microcrystalline p-Dichlorobenzene Loaded with 2-Mercaptobenzothiazole (2-Mercaptobenzothiazole이 내포된 p-Dichlorobenzene 미세결정으로 예비농축시킨 후 Cd(II) 정량)

  • Yoon, Ju-Im;Choi, Hee-Seon
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • A sensitive technique for the determination of trace Cd(II) in various real samples after preconcentration onto microcrystalline p-dichlorobenzene loaded with 2-mercaptobenzothiazole was developed. Several experimental conditions such as the pH of the sample solution, the amount of chelating agent 2-mercaptobenzothiazole, the amount of adsorbent p-dichlorobenzene-2-MBT, and the flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. Cu(II) interfered with more seriously than any other ions. However, the interference by Cu(II) could be overcome sufficiently by adjusting tartrate ion concentration to be 0.01M or by controlling the amount of 2-mercaptobenzothiazole contained in 0.20 g p-dichlorobenzene to be 0.12 g. The dynamic range, the correlation coefficient ($R^2$) and the detection limit obtained by this proposed technique were $0.5{\sim}30$ ng $mL^{-1}$, 0.9962, and 0.39 ng $mL^{-1}$, respectively. Thus, good results were obtained by the use of p-dichlorobenze as adsorbent matrix. For validating this proposed technique, the aqueous samples(wastewater, stream water, and reservoir water) and the plastic sample were used. Recovery yields of $93{\sim}104$ % were obtained. By F test, these measured data were not different from ICP-MS data at 95 % confidence level. Based on the results from the experiment, it was found that this proposed technique could be applied to the preconcentration and determination of Cd(II) in various real samples.

AN EVALUATION OF CHEMICAL DEGRADATION OF LIGHT-CURED RESTORATIVE COMPOSITES (광중합 복합레진의 화학적 분해 평가)

  • Yang, Kuy-Ho;Kim, Hun-Ju;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.530-539
    • /
    • 2003
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Charisma, Filtek P 60, Palpique Estelite, and Spectrum. Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 2 weeks they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth(${\mu}m$) - measured SEM and CLSM from polished circular sections of exposed specimens. The results were as follows: 1. The sequence of mass loss was in descending order by Palpique Estelite, Filtek P 60, Charisma, and Spectrum. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek P 60, Charisma, Palpique Estelita, and Spectrum. 3. The sequence of the Si loss was in descending order by Chrisma, Spectrum, Palpique Estelite, and Filtek P 60. 4. The correlation coefficient between mass loss and degradation layer depth was relatively high(r=0.704, p<0.05). 5. When observed with SEM, destruction of bonding was observed between resin matrix and filler. 6. When observed with CLSM, degradation layer depth of composite resin surface was observed.

  • PDF

Assessment of Genetic Diversity of Horse Breeds Using Microsatellite Makers (Microsatellite makers를 이용한 마품종 간의 평가 및 유전적 다양성)

  • Jung, Ji-Hye;Lee, Mi-Rang;Ha, Tae-Yong;Kim, Seon-Ku;Shin, Teak-Soon;Kang, Han-Seok;Lee, Hong-Gu;Cho, Gil-Jae;Park, Kyung-Do;Cho, Byung-Wook
    • Journal of Life Science
    • /
    • v.19 no.2
    • /
    • pp.169-173
    • /
    • 2009
  • To assist in selection schemes we estimate the genetic diversity of the horse breeds. Genetic diversity at 13 microsatellite loci was compared in six horse breeds : Jeju Native Horse, American Quarter, Jeju Racing Horse, Mongolian Horse, Japanese Horse and Thoroughbred. All of the equine microsatellite used in this study were amplified and were polymorphic. The expected total heterozygosity over all the populations varied between 0.669 and 0.869 and the expected heterozygosity within population range from 0.569 to 0.219 in this study. The low coefficient of gene differentiation value showed that only 0.118 of the diversity was between horses breeds. The constructed dendrogram from the genetic distance matrix showed little differentiation between horse breeds using DISPAN program. The genetic distance using 13 microsatellites ranged between 0.137 and 0.414 for the six horse breeds. These results confirm the potential use of equine microsatellite loci as a tool for genetic studies in horse populations. The genetic diversity of the six horse breeds to each other closed to their geographical distribution. Suggesting that the loci would be suitable for horse breeds parentage testing. Therefore, Microsatellite marker seems to be very useful for clarifying the evolutionary relationships of closely related populations.

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.