• Title/Summary/Keyword: Coefficient

Search Result 30,028, Processing Time 0.064 seconds

An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory (자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가)

  • Jeong, Jee Yeon;Park, Seunghyun;Yi, GwangYong;Lee, Naroo;You, Ki Ho;Park, Junsun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

The Non-Destructive Determination of Heavy Metals in Welding Fume by EDXRF (EDXRF에 의한 용접흄 중의 중금속의 비파괴 정량)

  • Park, Seunghyun;Jeong, Jee Yeon;Ryoo, Jang Jin;Lee, Naroo;Yu, Il Je;Song, Kyung Seuk;Lee, Yong Hag;Han, Jeong Hee;Kim, Sung Jin;Park, Jung sun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.229-234
    • /
    • 2001
  • The EDXRF(Energy Dispersive X-ray Fluorescence Spectrometer) technique was applied to the determination of heavy metals in welding fume. The EDXRF method designed in this study was a non-destructive analysis method. Samples were analyzed directly by EDXRF without any pre-treatment such as digestion and dilution. The samples used to evaluate this method were laboratory samples exposed in a chamber connected with a welding fume generator. The samples were first analyzed using a non-destructive EDXRF method. The samples subsequently were analyzed using AAS method to verify accuray of the EDXRF method. The purpose of this study was to evaluate the possibility of the non-destructive analysis of heavy metals in welding fume by EDXRF. The results of this study were as follow: 1.When the samples were collected under the open-face sampling condition, a surface distribution of welding fume particles on sample filters was uniform, which made non-destructive analysis possible. 2. The method was statistically evaluated according to the NIOSH(National Institute for Occupational Safety and Health) and HSE(Health and Safety Executive) method. 3. The overall precision of the EDXRF method Was calculated at 3.45 % for Cr, 2.57 % for Fe and 3.78 % for Mn as relative standard deviation(RSD), respectively. The limits of detection were calculated at $0.46{\mu}g$/sample for Cr, $0.20{\mu}g$/sample for Fe and $1.14{\mu}g$/sample for Mn, respectively. 4. A comparison between the results of Cr, Fe, Mn analyzed by EDXRF and AAS was made in order to assess the accuracy of EDXRF method. The correlation coefficient between the results of EDXRF and AAS was 0.9985 for Cr, 0.9995 for Fe and 0.9982 for Mn, respectively. The overall uncertainty was determined to be ${\pm}12.31%$, 8.64 % and 11.91 % for Cr, Fe and Mn, respectively. In conclusion, this study showed that Cr, Fe, Mn in welding fume were successfully analyzed by the EDXRF without any sample pre-treatment such as digestion and dilution and a good correlation between the results of EDXRF and AAS was obtained. It was thus possible to use the EDXRF technique as an analysis method of working environment samples. The EDXRF method was an efficient method in a non-destructive analysis of heavy metals in welding fume.

  • PDF

Possibility Estimating of Unaccessible Area on 1/5,000 Digital Topographic Mapping Using PLEIADES Images (PLEIADES 영상을 활용한 비접근지역의 1/5,000 수치지형도 제작 가능성 평가)

  • Shin, Jin Kyu;Lee, Young Jin;Choi, Hae Jin;Lee, Jun Hyuk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.299-309
    • /
    • 2014
  • This paper evaluated the possibility for 1/5,000 digital topographic mapping by using PLEIADES images of 0.5m GSD(Ground Sampling Distance) resolution that has recently launched. Those results of check points by applying the initial RPC(Rational Polynomial Coefficient) of PLEIADES images came out as; RMSE of those were $X={\pm}1.806m$, $Y={\pm}2.132m$, $Z={\pm}1.973m$. Also, if we corrected geometric correction using 16 GCP(Ground Control Point)s, the results of RMSE became $X={\pm}0.104m$, $Y={\pm}0.171m$, $Z={\pm}0.036m$, and t he RMSE of check points were $X={\pm}0.357m$, $Y={\pm}0.239m$, $Z={\pm}0.188m$; which of those results indicated the accuracy of standard adjustment complied in error tolerances of the 1/5,000 scale. Additionally, we converted coordinates of points, obtained by TerraSAR. for comparing with measurements from GPS(Global Positioning System) surveying. The RMSE of comparing converted and GPS points were $X={\pm}0.818m$, $Y={\pm}0.200m$, $Z={\pm}0.265m$, which confirmed the possibility for 1/5,000 digital topographic mapping with PLEIADES images and GCPs. As method of obtaining GCPs in unaccessible area, however, the outcome evaluation of GCPs extracted from TerraSAR images was not acceptable for 1/5,000 digital topographic mapping. Therefore, we considered that further researches are needed on applicability of GCPs extracted from TerraSAR images for future alternative method.

Mathematical Transformation Influencing Accuracy of Near Infrared Spectroscopy (NIRS) Calibrations for the Prediction of Chemical Composition and Fermentation Parameters in Corn Silage (수 처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 및 발효품질의 예측 정확성에 미치는 영향)

  • Park, Hyung-Soo;Kim, Ji-Hye;Choi, Ki-Choon;Kim, Hyeon-Seop
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • This study was conducted to determine the effect of mathematical transformation on near infrared spectroscopy (NIRS) calibrations for the prediction of chemical composition and fermentation parameters in corn silage. Corn silage samples (n=407) were collected from cattle farms and feed companies in Korea between 2014 and 2015. Samples of silage were scanned at 1 nm intervals over the wavelength range of 680~2,500 nm. The optical data were recorded as log 1/Reflectance (log 1/R) and scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares (PLS) multivariate analysis in conjunction with several spectral math treatments to reduce the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation ($R^2{_{cv}}$) and the lowest standard error of cross validation (SECV). Results of this study revealed that the NIRS method could be used to predict chemical constituents accurately (correlation coefficient of cross validation, $R^2{_{cv}}$, ranging from 0.77 to 0.91). The best mathematical treatment for moisture and crude protein (CP) was first-order derivatives (1, 16, 16, and 1, 4, 4), whereas the best mathematical treatment for neutral detergent fiber (NDF) and acid detergent fiber (ADF) was 2, 16, 16. The calibration models for fermentation parameters had lower predictive accuracy than chemical constituents. However, pH and lactic acids were predicted with considerable accuracy ($R^2{_{cv}}$ 0.74 to 0.77). The best mathematical treatment for them was 1, 8, 8 and 2, 16, 16, respectively. Results of this experiment demonstrate that it is possible to use NIRS method to predict the chemical composition and fermentation quality of fresh corn silages as a routine analysis method for feeding value evaluation to give advice to farmers.

Determination and Survey of Fluoroquinolones Residue in Chicken Muscle by HPLC with Fluorescence Detector (액체크로마토그래피-형광검출기를 이용한 닭고기 중 플루오로퀴놀론계 항균물질 정량분석 및 잔류조사)

  • 박은정;임지흔;이성모
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.1
    • /
    • pp.12-18
    • /
    • 2004
  • Ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin in chicken muscle were seperated by liquid extraction and determined with high performance liquid chromatography (HPLC) with fluorescence detector. Analysis was carried out using following conditions; Cl8 column (250${\times}$4.6 mm i.d. 5 ${\mu}{\textrm}{m}$ particle size), mobile phase composed of D.W. (containing 0.4% triethylamine and phospholic acid): methanol : acetonitrile (800:100:100, v/v/v), isocratic pump at a flow rate of 1.0 $m\ell$/min and 50 ${mu}ell$ of injection volume, fluorescence detector with EX278 nm/EM.456 nm. The calibration curves of four fluoroquinolones showed linearity (${\gamma}$$^2$$\geq$0.999) at concenration range of 0.025-0.6 $\mu\textrm{g}$/ml. The recoveries in fortified chicken muscle represented more than 80% with low coefficient of variation (〈10%) for concentration range of four fluoroquinolones. The detection limits for ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin were 23.5, 3.4, 3.0 and 2.5 ng/g in chicken muscle, respectively. We also monitored fluoroquinolones residue in muscle of chickens (broiler 1:227, Korean native chicken 219, laying chicken 77) using EEC-4-plate screening and HPLC conformation methods. Ten(broiler 5, Korean native chicken 5) out of the fifteen samples which were positively detected by EEC-plate screening method from 1,523 chicken meat were confirmed with ciprofloxacin and enrofloxacin by HPLC. The ranges of residual concentration were 0-0.12 ppm for ciprofloxacin and 0.01-6.79 ppm for enrofloxacin. In conclusion, our method could be applied effectively to determine four fluoroquinolones residues in chicken meat, and further survey for fluoroquinolones residue in chicken meat are needed for more effective control of fluoroquinolones used in livestock.

A Study on the Analysis of Five Artificial Sweetners in Beverages by HPLC/MS/MS (HPLC/MS/MS를 이용한 음료류 중 인공감미료 동시분석에 관한 연구)

  • Lee, Seong-Bong;Yong, Kum-Chan;Hwang, Sun-Il;Kim, Young-Su;Jung, You-Jung;Seo, Mi-Young;Lee, Chang-Hee;Sung, Jin-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.327-333
    • /
    • 2014
  • A method for analysis of five artificial sweetners (sodium saccharin, aspartame, acesulfame-K, sucralose, cyclamate) in beverage samples was developed using high-performance liquid chromatography/triple quadrupole mass spectrometry (HPLC/MS/MS). The method uses a single-step dilution for sample preperation. Seperation was achieved on a $C_{18}$ column ($2.1{\times}150mm$, $3.5{\mu}m$) with A- 2% methanol (1 mM ammonium acetate), B-95% methanol (1 mM ammonium acetate) as mobile phase with gradient mode. The quantitation of target compounds was performed by external calibration in selected reaction monitorning (SRM) mode. The coefficient of determination of calibration curve for sodium saccharin, aspartame, acesulfame-K, sucralose and cyclamate were 0.9957, 0.9991, 0.9943, 0.9982 and 0.9948, respectively. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 0.001~0.022 mg/L and 0.004~0.073 mg/L, repectively. Recoveries for beverage samples were in the range of 92.76~113.50% with RSD < 10.91%. The method has applied to the determination of the five sweetners in 102 beverage samples. Three artificial sweetners-aspartame, acesulfame-K, sucralose were detected from 42 samples. Sodium saccharin and cyclamate were not detected in all samples.

Analytical Method Development for Determination of Silymarin by LC-MS/MS for Related Health Functional Foods (LC-MS/MS를 이용한 건강기능식품 중 실리마린 분석법 연구)

  • Oh, Mihyune;Lee, Jin Hee;Kim, Sang-A;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.124-130
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for the use of health functional foods (dietary food supplement), in order to establish regulatory standards and specifications in Korea. In this regard, we continue to pursue and perform our research on the analytical method development for the items being researched and reviewed. In this study, we have developed a sensitive and selective test method that could simultaneously separate and determinate six major bioactive flavonolignans in silymarin, which are based on the use of a liquid chromatographic-tandem mass spectrometry (LC-MS/MS). The standard calibration curves presented a linearity effect with the correlation coefficient ($r^2$) > 0.999. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of $0.3{\sim}9.0{\mu}g/L$ and $0.8{\sim}27.3{\mu}g/L$, respectively. The recovery results ranged between 96.2~98.6% at 3 different concentration levels, and its relative standard deviations (RSDs) were less than 5% as noted in this study. The proposed analytical method was characterized with a noted high resolution of the individual silymarin constituents, and the assay was fully validated as well. Our research can provide a significant scientific evidence that can be useful to amend the silymarin test method for the Health Functional Food Code.

Changes in Ion Balance and Individual Ionic Contributions to EC Reading at Different Renewal Intervals of Nutrient Solution under EC-based Nutrient Control in Closed-loop Soilless Culture for Sweet Peppers (Capsicum annum L. 'Fiesta') (EC 기준 파프리카 순환식 수경재배에서 양액 교체 주기에 따른 양액 중의 이온 균형 및 각 이온의 EC 기여도 변화)

  • Ahn, Tae-In;Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.29 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • Individual ion concentrations and ionic contributions to EC reading in the circulated nutrient solution are the important factors to be considered for stable EC-based closed-loop soilless culture. This study was conducted to determine appropriate ion-analysis intervals of the circulated nutrient solutions based on ion concentration, ion balance, and ion electrical conductivity under different renewal intervals in EC-based nutrient control systems for sweet peppers (Capsicum annum L. 'Fiesta') in early growth stage. Average node numbers of the plants were 13 and 18 when the experiment started and finished, respectively, and three plants were grown in each rockwool slab. Four different renewal intervals of circulated nutrient solutions such as 1, 2, 3, and 4 weeks were used as treatment. Nutrient solutions were supplied to the plants based on integrated radiation. Drainage was collected into drain tanks after irrigation ended in the day and then mixed with fresh water until the EC reaches 2.69 $dS{\cdot}m^{-1}$. The replenished nutrient solution was supplied to the plants in the next day. Ion concentrations of the individual ions periodically analyzed in the circulated nutrient solutions showed no significant differences among the treatments during the experimental period. Ion concentrations of $K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$, $NO_3{^-}$, ${SO_4}^{2-}$, ${PO_4}^{3-}$, and $Cl^-$ varied within 5-8, 11-14, 2.0-2.7, 0.5-0.6, 14-19, 4-5, 1-4, and 0.3-0.5 $meq{\cdot}L^{-1}$, respectively. Ion balance showed a consistent tendency over all the treatments and especially $K^+$ : $Ca^{2+}$ and ${SO_4}^{2-}$ : ${PO_4}^{3-}$ played great roles in the cation and anion balances in the nutrient solutions, respectively. Activity coefficients of ions such as $K^+$, $NO_3{^-}$, and $H_2PO_4{^-}$ varied within 0.8-0.9 and those of $Ca^{2+}$, $Mg^{2+}$, ${SO_4}^{2-}$ varied within 0.5-0.6, showing little changes with time. Ionic contributions of $K^+$ and $NO_3{^-}$ to EC reading were the greatest followed by $Ca^{2+}$, ${SO_4}^{2-}$, and $Mg^{2+}$ in the order. From the results, we thought that allowable ranges in ion concentration, ion balance, and subsequent individual ionic contributions to EC reading would be obtained within 4-week renewal interval of nutrient solution in EC-based closed-loop soilless culture for sweet pepper plants.

Association between picky eating behaviors and growth in preschool children (유아기 까다로운 식습관과 성장상태 간의 연관성)

  • Shim, Jae Eun;Yoon, Ji Hyun;Kim, Kijoon;Paik, Hee Young
    • Journal of Nutrition and Health
    • /
    • v.46 no.5
    • /
    • pp.418-426
    • /
    • 2013
  • This study was conducted in order to investigate the association between picky eating behaviors of preschool children and growth outcomes. In this study, picky eating behaviors were defined as containing four constructs of 'eating a small amount (ES),' 'neophoic behavior (NB),' 'refusal of specific food groups (RF),' and 'preference for specific food-preparation methods (PP).' A 7-point scale was used for the multi-item questionnaire, which consisted of 21 items (three items for ES, two items for NB, nine items for RF, and seven items for PP), in order to evaluate picky eating behaviors of children. Subjects were recruited among visitors at a medical clinic in Seoul. A total of 150 self-administered survey responses from parents of preschool children were analyzed in order to investigate the association between picky eating behaviors of preschool children and growth outcomes. Height for age (HFA) and weight for height (WFH) z-scores were used for assessment of preschool children's growth. The prevalence of ES, NB, RF, and PP was 44%, 57%, 73%, and 53%, respectively. Children with ES had lower HFA (p < 0.05) and WFH (p < 0.0001) than those without ES, while children with NB, RF, or PP had HFA and WFH were similar to their counterparts. The mean HFA z-score of children with ES was less than 0 (p < 0.05) and the mean WFH z-scores of children with ES, NB, RF, or PP were less than 0 (p < 0.05). According to the study results, related growth outcome differed depending on constructs of picky eating behaviors. In particular, picky eating of ES showed a risk of faltering height growth in preschool children. Further comprehensive studies on the reason for ES and intervention approach is warranted.

Development and relative validity of semi-quantitative food frequency questionnaire for Korean adults (한국인을 위한 반정량 식품섭취빈도 조사지의 개발 및 타당도 연구)

  • Kim, Sohye;Lee, Jung Sug;Hong, Kyung Hee;Yeom, Hye Sun;Nam, Yeon Seo;Kim, Ju Young;Park, Yoo Kyung
    • Journal of Nutrition and Health
    • /
    • v.51 no.1
    • /
    • pp.103-119
    • /
    • 2018
  • Purpose: This study was implemented to develop and validate the semi-quantitative food frequency questionnaire (SQ-FFQ) to assess energy, carbohydrates, fat, protein, minerals, and vitamins as well as fatty acids and alcohol in Korean adults. Methods: The SQ-FFQ consisted of 88 food items, and 12 food groups were selected based on information of frequently consumed foods from the Korean Health and Nutrition Examination survey. Each portion size was categorized as one of three amounts: small (0.5 times), medium (1 time), and large (1.5 times). A total of 111 subjects finished 3-day diet records and the SQ-FFQ. The relative validity of SQ-FFQ was assessed by comparison with the 3-day diet records. Results: The mean nutrient intakes obtained from the SQ-FFQ were estimated to be greater than those of the two 3-day dietary records. Spearman's correlation coefficient between the two methods was the highest for energy (r = 0.583; p < 0.001) and lowest for saturated fatty acid (r = 0.121). Correlation coefficients were energy (r = 0.583; p < 0.001), carbohydrates (r = 0.500; p < 0.001), protein (r = 0.466; p < 0.001), fat (r = 0.411; p < 0.001), dietary fiber (r = 0.467; p < 0.001), alcohol (r = 0.527; p < 0.001), calcium (r = 0.409; p < 0.001), phosphorus (r = 0.499; p < 0.001), potassium (r = 0.418; p < 0.001), magnesium (r = 0.427; p < 0.001), and zinc (r = 0.464; p < 0.001), respectively, for all subjects. Conclusion: The developed SQ-FFQ in this study seems to be useful for estimating nutritional status, particularly energy, carbohydrates, protein, fat, dietary fiber, alcohol, calcium, phosphorus, potassium, magnesium, and zinc of Korean adults.