Relationship between Secondary Electron Emissions and Film Thickness of Hydrogenated Amorphous Silicon

  • Yang, Sung-Chae;Chu, Byung-Yoon;Ko, Seok-Cheol;Han, Byoung-Sung
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.185-189
    • /
    • 2004
  • The temporal variation of a secondary electron emission coefficient (${\gamma}$ coefficient) of hydrogenated amorphous silicon (a-Si:H) was investigated in a dc silane plasma. Estimated ${\gamma}$ coefficients have a value of 2.73 ${\times}$ 10$^{-2}$ on the pure aluminum electrode and 1.5 ${\times}$ 10$^{-3}$ after 2 hours deposition of -Si:H thin films on a cathode. It showed an abrupt decrease for about 30 minutes before saturation. The variation of the ${\gamma}$ coefficient was estimated as a function of the thin film thickness, and the film thickness was about 80 nm after 30 minutes deposition time. These results are compared with the results of a computer simulation for ion penetration into a cathode.

Friction Characteristics of CNx Coated Dimple Pattern with Hexagonal Array (CNx 코팅된 육각대열 딤플패턴의 마찰특성)

  • Choi, Won-Sik;Umehara, Noritsugu
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.264-268
    • /
    • 2011
  • In this study, we examined the friction characteristics of a dimple pattern on a carbon nitride coating. The study was conducted with a hexagonal array 40 ${\mu}m$ dimple pattern on a steel bearing containing a CNx coating. The area density of the dimple patterns were varied between 5% and 25%, the speed was varied from 0.06-0.26 m/s, and the load was varied between 20-100N. In general, we found that as the velocity increased, the friction coefficient increased. Furthermore, the friction coefficient was lowest at a load of 40N. The friction coefficient of the non-coated specimen was 0.025-0.15; on the other hand, the friction coefficient of the coated specimen was 0.002-0.02. Thus, we determined that the coated materials could reduce the friction coefficient by a factor of 7.5.

Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration (저압나노여과에 의한 각종 중금속의 제거 특성)

  • Oh, Jeong-Ik;Kim, Han-Seung;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.

Study on Characteristics of Flow Boiling Heat Transfer in Multi channels (수평 다채널 관에서의 유동 비등 열전달 특성에 관한 연구)

  • CHOI, Yong-Seok;LIM, Tae-Woo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1310-1317
    • /
    • 2015
  • Two-phase flow boiling heat transfer in micro-channels was experimently investigated. The test section consisted of 15 rectangular micro-channels with a depth of 0.45mm, width of 0.20mm. The experiments were performed for heat fluxes ranging from 5.6 to 46.1kW/m2 and mass fluxes from 150 to 450kg/m2s using FC-72 as the working fluid. According to the results, at the low heat flux region, heat transfer coefficient strongly depends on the heat flux, while heat transfer coefficient at the high heat flux region was independent on the heat flux. Four correlations were used to predict the heat transfer coefficient. The measured heat transfer coefficient was compared with four correlations. It was found that Kaew-On and Wongwises's correlation well predicted the measured data, within the MAE of 40.3%.

Evaluation on MUSLE Runoff Energy Coefficient in Small Forest Watershed (산림소유역에서 MUSLE 유출에너지인자 계수값의 적용성 평가)

  • Kim, Jaehoon;Choi, Hyung Tae;Lim, Hong-geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.191-200
    • /
    • 2015
  • This study was carried out to investigate coefficient and exponent of runoff energy in MUSLE for small forest watershed, Hwachoen watershed in Gangwon-do. For 15 rainfall events, runoff volume, peak discharge and sediment yield were measured and these data were used to calculate coefficient and exponent of runoff energy. The results of this study showed that $LS{\bullet}K{\bullet}C{\bullet}P$ factors of MUSLE were affected by slope steepness. The coefficient and exponent of runoff energy were validated with coefficient of efficiency of 0.92 and these values were suggested to 0.002 and 0.81 respectively. The comparison of the coefficients and exponents between Hwacheon and other forest watersheds showed that these values would reflect the effect of forest management within watershed.

A Study for Evaporation Heat Transfer Characteristic of R22/Rl14 Refrigerant Mixtures in a Horizontal Tube (수평증발관내 R22/R114 혼합냉매의 열전달 특성에 관한 연구)

  • 윤치한;이종인;하옥남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.502-510
    • /
    • 2000
  • Evaporation heat transfer characteristics were studied in a horizontal tube using R22/R114 non-azotropic refrigerant mixture. the heat transfer coefficient was high in the upper part for pure refrigerants, and heat transfer coefficient was low in the lower part for refrigerant mixtures. In the low quality region where nucleate boiling was dominant, the average heat transfer coefficient was low. In the region where forced convection was dominant, heat transfer coefficient was high. Results show that the heat transfer coefficient for pure refrigerants obtained by experiments were lower than those of Yoshida et al. but agreed well with Jung et al., and Chen et al. data. But the heat transfer coefficients for refrigerant mixtures were lower about 20% than those predicted by the equation for pure refrigerant.

  • PDF

A Study on Chloride ion Diffusion in Cracked Concrete (균열이 발생한 콘크리트에서의 염화물 이온 확산에 관한 연구)

  • 배상운;박상순;변근주;송하원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.677-682
    • /
    • 2001
  • In this study, a method to evaluate diffusion coefficient of chloride ion in cracked concrete is proposed. For cracked concrete having either anisotropic or isotropic crack network, each crack of saturated concrete is considered as a V shape crack, and an effective diffusion coefficient is expressed with diffusion coefficients of cracked part and noncracked part and a so-called crack spacing factor. A comparison with experimental results shows that the diffusion coefficient for cracked concrete is accurately predicted by the effective diffusion coefficient. Prediction results also show that the cracks in concrete markedly change the diffusion properties and accelerate penetration of drifting species. The method in this paper can be effectively used to consider the effect of cracks on concrete diffusion coefficient of cracked concrete.

  • PDF

Censored varying coefficient regression model using Buckley-James method

  • Shim, Jooyong;Seok, Kyungha
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1167-1177
    • /
    • 2017
  • The censored regression using the pseudo-response variable proposed by Buckley and James has been one of the most well-known models. Recently, the varying coefficient regression model has received a great deal of attention as an important tool for modeling. In this paper we propose a censored varying coefficient regression model using Buckley-James method to consider situations where the regression coefficients of the model are not constant but change as the smoothing variables change. By using the formulation of least squares support vector machine (LS-SVM), the coefficient estimators of the proposed model can be easily obtained from simple linear equations. Furthermore, a generalized cross validation function can be easily derived. In this paper, we evaluated the proposed method and demonstrated the adequacy through simulate data sets and real data sets.

INFLUENCE OF EDDY VISCOSITY COEFFICIENT ON ${\kappa}-{\varepsilon}$ TURBULENCE MODEL FOR SUPERSONIC BASE FLOW (초음속 기저부 유동에서 ${\kappa}-{\varepsilon}$ 난류 모델에 대한 와점성 계수의 영향)

  • Park, Soo-Hyung;Sa, Jeong-Hwan;Kim, Jee-Woong;Kwon, Jang-Hyuk;Kim, Chang-Joo
    • Journal of computational fluids engineering
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • A supersonic base flow is computed to investigate the effect of the eddy viscosity coefficient to the linear ${\kappa}-{\varepsilon}$ turbulence models. Slight modifications to the eddy viscosity coefficient, which are based on the realizability condition, are given to the Launder-Sharma turbulence model so that present models satisfy the realizability condition. Numerical results for supersonic base flow show that turbulence models with the weaky-nonlinear eddy viscosity coefficient can lead to reasonable enhancements in the prediction of the velocity and turbulent kinetic energy profiles.

A new consideration for the heat transfer coefficient and an analysis of the thermal stress of the high-interim pressure turbine casing model (열전달계수에 대한 새로운 고찰 및 고-중압 터빈 케이싱 모형의 열응력 해석)

  • Um, Dall-Sun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.425-429
    • /
    • 2004
  • In real design of the high & interim pressure turbine casing, it is one of the important things to figure out its thermal strain exactly. In this paper, with the establishment of the new concept for the heat transfer coefficient of steam that is one of the factors in analysis of the thermal stress for turbine casing, an analysis was done for one of the high & interim pressure turbine casings in operating domestically. The sensitivity analysis of the heat transfer coefficient of steam to the thermal strain of the turbine casing was done with a 2-D simple model. The analysis was also done with switching of the material properties of the turbine casing and resulted in that the thermal strain of the turbine casing was not so sensitive to the heat transfer coefficient of steam. On the basis of this, 3-D analysis of the thermal strain for the high and interim pressure turbine casing was done.

  • PDF