• Title/Summary/Keyword: Cobalt-chromium

Search Result 102, Processing Time 0.056 seconds

Reevaluation of the Metabolic Essentiality of the Minerals - Review -

  • Spears, J.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.1002-1008
    • /
    • 1999
  • Essential metabolic functions have been identified for seven macrominerals (calcirum, phosprorus, magnesium, sodium, potassium, chloride, and sulfur), and eight microminerals (cobalt, copper, iodine, iron, manganese, molybdenum, selenium, and zinc). Major functions for each of these minerals are summarized. Considerable research suggests that chromium is also essential and that it functions by facilitating insulin activity. Studies are reviewed which indicate that chromium supplementation of animal diets may: 1) increase glucose removal from blood, 2) reduce carcass fat and increase lean in nonruminants, 3) alter egg cholesterol content, and 4) enhance immunity and disease resistance in ruminants. A number of other minerals including nickel, boron, vanadium, arsenic, silicon, lithum, and lead have been reported to be essential, but specific metabolic functions have not been defined for any of these elements. Limited research in poultry suggests that boron may be of practical significance in some instances.

A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA (시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구)

  • Kwak, Chun;Kim, Jim-Bom;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

Recent updates for biomaterials used in total hip arthroplasty

  • Hu, Chang Yong;Yoon, Taek-Rim
    • Biomaterials Research
    • /
    • v.22 no.4
    • /
    • pp.259-270
    • /
    • 2018
  • Background: Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods: A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'total hip arthroplasty', 'biomaterials', 'stainless steel', 'cobalt-chromium', 'titanium', 'polyethylene', and 'ceramic'. Results: The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion: This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.

Effects of Cobalt Protective Coating Prepared by DC Electroplating on Ferritic Stainless Steel for SOFC Interconnect (직류 전기도금을 이용한 고체산화물 연료전지 금속연결재용 페라이트계 스테인리스 스틸의 코발트 보호막 코팅 효과)

  • Hong, Jong-Eun;Lim, Tak-Hyung;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul;Yoo, Young-Sung;Lee, Dok-Yol
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.2
    • /
    • pp.116-124
    • /
    • 2009
  • We investigated the influences of cobalt coating deposited by DC electroplating on the ferritic stainless steel, STS 430, as a protective layer on a metallic interconnect for SOFC applications. Cobalt coated STS 430 revealed a uniform and denser-packing oxide surface and a reduced growth rate of $Cr_2O_3$ scales after oxidation at $800^{\circ}C$in air. Cobalt coating layer was oxidized to $CoCo_2O_4$ and Co containing mixed oxide spinels such as $Co_2CrO_4$, $CoCr_2O_4$, and $CoCrFeO_4$. The area specific resistance value of Co coated sample was $0.020\;{\Omega}cm^2$ lower than that of uncoated at $800^{\circ}C$ in air during 500 h. After 1000 h oxidation, cobalt oxide coating layer suppressed chromium outward diffusion.

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

A Study on the Characterization on Some Semiconuctor Materials by Neutron Activation Analysis. Characterization of Semiconductor Silicon

  • Lee Chul;Kwun Oh Cheun;Kim Ho Kun;Lee Jong Du;Chung Koo Soon
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.1
    • /
    • pp.30-32
    • /
    • 1989
  • Traces of nine elements, gold, arsenic, cobalt, chromium, copper, europium, hafnium, sodium and antimony in commercially available silicon crystals were determined by the instrumental neutron activation analysis using the single comparator method. The values of the concentrations of these elements in both single and polycrystals were found to decrease significantly to a low limiting level by simply washing and etching surface contaminants having been introduced during various steps of sample preparation and irradiation. However, the chromium levels in polycrystals were not easily decreased, these depending upon the cutting tools employed. The Sb-doped content in each semiconductor has been compared with the associated quantities such as the concentration and the conductivity range given by the sample donor. Uncertainty in the sodium analysis due to the fission neutron reaction by silicon itself was discussed.

Evaluation of Marginal and Internal Gap of Cobalt-Chromium Sintering Metal Coping Fabricated by Dental CAD/CAM System (치과 CAD/CAM 시스템으로 제작한 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도 평가)

  • Kim, Dong-Yeon;Sin, Chun-Ho;Jung, Il-Do;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.536-541
    • /
    • 2015
  • The purpose of this study was to evaluate the marginal and internal gap of Cobalt (Co)-Chromium (Cr) sintering metal coping fabricated by dental computer-aided design/computer-aided manufacturing systems. Abutment tooth 46 of universal numbering system was selected for the study. Twenty Co-Cr metal copings of two groups were manufactured and scanned. Co-Cr cast metal copings (CCM) group of ten were fabricated using investment, burnout and casing after subtractive manufacturing of wax block. Also, Co-Cr sintering metal copings (CSM) group of ten were fabricated using sintering processing after subtractive manufacturing of Co-Cr soft metal bock. Marginal and internal gap of Co-Cr metal copings of twenty were measured by digital microscope (${\times}160$) with silicone replica technique. The data was analyzed from IBM SPSS Statistics ver. 22.0 Statistical software for Mann-Whitney U test (${\alpha}=0.05$). $Mean{\pm}standard$ deviation of marginal gap of CCM group was $90.12{\pm}61.73{\mu}m$ of CSM group was $60.17{\pm}24.83{\mu}m$. However, two groups was statistically not different (p>0.05). This study showed that CSM group was clinically acceptable adaptation.

Metal Concentrations Analysed in the Inorganic Bulk Pigment Samples by ICP-AES and the Provision Rate of MSDS and Agreement Rate with MSDS (우리 나라에서 제조/사용하는 일부 무기 안료중 ICP-AES를 이용한 주요 중금속 농도와 MSDS 비치율 및 일치율 비교)

  • Kim, Hyoung-Ah;Lee, Kyoung-Joo;Kim, Yong-Woo;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.196-208
    • /
    • 1998
  • To improve the quality of environmental measurements and evaluation of the workplace air in the pigment manufacturing industries, we analyzed metal(chromium, cadmium, lead, iron, cobalt, manganese, antimony, titanium, arsenic, and selenium) concentrations by ICP-AES in sixty seven samples of inorganic bulk pigments which are produced and/or used in Korea. We also collected MSDS which has to be supplied by manufacturer and/or supplier and posted in the workplace according to the Hazard Communication Standards, and compared the number of metals listed in each MSDS with the number of metals determined by ICP-AES. Results were as followed; 1. Among seventeen yellowish-colored samples, chromium(2~19%) and lead(0.1~61%) were the two major metals. In thirteen reddish-colored samples, iron was the major component with 37~81%. Cobalt and manganese were detected in blue-colored samples with less than 1%, while antimony and titanium were the major two metals in white-colored pigments with 178~300 ppm and with 36~65%, respectively. 2. In area samples collected in workplace air(one pigments producing factory and five retailer stores), iron and manganese were detected but the concentrations not exceeded the TLVs(1 and $5mg/m^3$, respectively). In three of fifteen samples, the concentrations of lead exceeded the TLV ($0.05mg/m^3$). 3. Two out of seven companies provided MSDS, and the average provision rate was 22.4%. And the coincidence rate of the number of metals referenced in MSDS and determined by ICP-AES mostly accorded, but in one sample, different metal was detected from MSDS. In summary, metals have to be concerned in evaluation of the workplace air dealing with compounds of inorganic pigments dust are cobalt, chromium, iron, manganese, lead and antimony, and these are simultaneously determined by ICP-AES. Taking this opportunity, it is needed to reinforce that the personnel is to be concerned about prevention of workers' ill health regarding to provision of MSDS.

  • PDF