• 제목/요약/키워드: Coating Flow

검색결과 402건 처리시간 0.03초

Friction Behavior of High Velocity Oxygen Fuel (HVOF) Thermal Spray Coating Layer of Nano WC-Co Powder

  • Cho, T.Y.;Yoon, J.H.;Kim, K.S.;Fang, W.;Joo, Y.K.;Song, K.O.;Youn, S.J.;Hwang, S.Y.;Chun, H.G.
    • 한국표면공학회지
    • /
    • 제40권4호
    • /
    • pp.170-174
    • /
    • 2007
  • High Velocity Oxygen Fuel (HVOF) thermal spray coating of nano size WC-Co powder (nWC-Co) has been studied as one of the most promising candidate for the possible replacement of the traditional hard plating in some area which causes environmental and health problems. nWC-Co powder was coated on Inconel 718 substrates by HVOF technique. The optimal coating process obtained from the best surface properties such as hardness and porosity is the process of oxygen flow rate (FR) 38 FMR, hydrogen FR 57 FMR and feed rate 35 g/min at spray distance 6 inch for both surface temperature $25^{\circ}C\;and\;500^{\circ}C$. In coating process a small portion of hard WC decomposes to less hard $W_2C$, W and C at the temperature higher than its decomposition temperature $1,250^{\circ}C$ resulting in hardness decrease and porosity increase. Friction coefficient increases with increasing coating surface temperature from 0.55-0.64 at $25^{\circ}C$ to 0.65-0.76 at $500^{\circ}C$ due to the increase of adhesion between coating and counter sliding surface. Hardness of nWC-Co is higher or comparable to those of other hard coatings, such as $Al_2O_3,\;Cr,\;Cr_2O_3$ and HVOF Tribaloy 400 (T400). This shows that nWC-Co is recommendable for durability improvement coating on machine components such as high speed spindle.

Issues in IT Rheology

  • Ahn Kyung-Hyun;Lee Seung-Jong
    • 한국유변학회:학술대회논문집
    • /
    • 한국유변학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.15-15
    • /
    • 2006
  • PDF

수종의 구취처치법의 구치감소효과에 관한 연구 (Effect of Tongue Scraping, ZnCl2 Mouth Rinse, and Periodontal Treatment on the Reduction of Oral Malodor)

  • 박종훈;한경수;김문규
    • Journal of Oral Medicine and Pain
    • /
    • 제25권1호
    • /
    • pp.41-51
    • /
    • 2000
  • This study was performed to investigate the effect of three modalities commonly used for reduction of oral malodor and to review the contributing factors for halitosis. For this study, 45 subjects of good general health in their third decades were selected, and they were divided into three groups by each modality, that is, tongue scraping, $ZnCl_2$ mouth rinse, and periodontal treatment. Subjective sense of halitosis, diets, Oral hygiene index based on tooth brushing and tongue brushing habit, resting salivary flow rate, gingival index, degree of tongue coating were recored in the Halito-Chart designed by the author. Oral malodor converted from volatile sulfur compound was measured by the Halimeter$^{(R)}$(Interscan Co., USA), and the correlation between the oral factors and pre-treatment halimeter score were analysed. Data obtained were analysed by the SPSS windows program and the results of this study were as follows : 1. There were no significant correlation between oral factors such as oral hygiene index, salivary flow rate, gingival index, degree of tongue coating and pre-treatment halimeter score. 2. Difference between pre- and post-treatment halimeter score by the three modalities were significant, but correlation between pre- and post-treatment score within group was most significant in the periodontal treatment group followed by the tongue scraping group and lowest in the $ZnCl_2$ mouth rinse group. 3. Reduction of halimeter score was significant only in subjects with relatively more tongue coating in the tongue scraping group, but in the $ZnCl_2$ mouth rinse group and in the periodontal treatment group, the modality applied to each group had same significant effects without regard to the degree of oral hygiene index or gingival index. 4. Men had more tongue coating than women, and reduction of halimeter score was significant in men, but not in women.

  • PDF

WC-10Co4Cr으로 초고속 화염용사 코팅된 Cu 합금의 해수내 캐비테이션 손상 거동 (Behaviors of Cavitation Damage in Seawater for HVOF Spray Coated Layer with WC-10Co4Cr on Cu Alloy)

  • 한민수;김민성;장석기;김성종
    • 한국표면공학회지
    • /
    • 제45권6호
    • /
    • pp.264-271
    • /
    • 2012
  • Due to the good corrosion resistance and machinability, copper alloy is commonly employed for shipbuilding, hydroelectric power and tidal power industries. The Cu alloy, however, has poor durability, and the seawater application at fast flow condition becomes vulnerable to cavitation damage leading to economic loss and risking safety. The HVOF(High Velocity Oxygen Fuel) thermal spray coating with WC-10Co4Cr were therefore introduced as a replacement for chromium or ceramic to minimize the cavitation damage and secure durablility under high-velocity and high-pressure fluid flow. Cavitation test was conducted in seawater at $15^{\circ}C$ and $25^{\circ}C$ with an amplitude of $30{\mu}m$ on HVOF WC-10Co4Cr coatings produced by thermal spray. The cavitation at $15^{\circ}C$ and $25^{\circ}C$ exposed the substrate in 12.5 hours and in 10 hours, respectively. Starting from 5 hours of cavitation, the coating layer continued to show damage by higher than 160% over time when the temperature of seawater was elevated from $15^{\circ}C$ to $25^{\circ}C$. Under cavitation environment, although WC-10Co4Cr has good wear resistance and durability, increase in temperature may accelerate the damage rate of the coating layer mainly due to cavitation damage.

구리합금에 대한 WC-27NiCr 초고속화염용사 코팅층의 해수내 캐비테이션 특성 평가 (Evaluation of Cavitation Characteristics in Seawater on HVOF Spray Coated Layer with WC-27NiCr Material for Cu Alloy)

  • 한민수;김민성;장석기;김성종
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.263-269
    • /
    • 2012
  • Copper alloys are commonly applied to ship's propellers, pumps and valves which are serviced in seawater due to their good castability and corrosion resistance. In the environment of high flow velocity, however, erosion damage predominates over corrosion damage. In particular, the cavitation in seawater environment accelerates surface damage to copper alloys, resulting in degradation of products and economic losses and also threatening safety. The surface was coated with WC-27NiCr by high velocity oxygen fuel(HVOF) spraying technique to attain durability and cavitation resistance of copper alloys under high velocity/pressure flow. The cavitation test was performed for the WC-27NiCr coating deposited by HVOF in seawater at the amplitude of $30{\mu}m$ with seawater temperature. The cavitation at $15^{\circ}C$ caused exfoliation of the coating layer in 17.5 hours while that of $25^{\circ}C$ caused the exfoliation in 12.5 hours. When the temperature of seawater was elevated to $25^{\circ}C$ from $15^{\circ}C$, more damage was induced by over 160%. Although WC-27NiCr has good durability, corrosion resistance and eletrochemical stability, the cavitation damage rate of the coating layer could remarkably increase at the elevated temperatures under cavitation environments.

종이 도공용 라텍스의 계면(界面) 및 유동특성(流動特性)에 관한 연구(硏究) (Interfacial and Flow Properties of Latices for Paper Coating)

  • 이용규
    • Journal of the Korean Wood Science and Technology
    • /
    • 제22권1호
    • /
    • pp.85-90
    • /
    • 1994
  • The flow properties of binder latices for paper coating were investigated, together with dynamic viscoelastic properties of latex films and electron micrographs of latices, under various conditions. The amphoteric latex, binder pigment latex and anionic latex were used in this work. The amphoteric latex has both anionic and cationic functional group on its surface. The binder-pigment with a core-shell structure has dual functions : plastic pigment and binder. The low shear viscosity of binder latices and clay slurry were measured with Brookfield vis cometer. At low-shear rates. the viscosity decreased with increasing particle size of latex. On the amphoteric latex surface, the carboxyl groups are assumed to be fully dissociated over the region of pH 9~12, but the density of negative groups seems to be increased because of the gradual decrease in the degree of dissociation of amino groups. Since the apparent particle size of latex increases with surface charge, the electroviscous effect can be observed. On the anionic latex surface, the charge density is assumed to be nearly constant above pH 8. However, below pH 8 the coagulation of particles could be observed probably because of the decrease in the charge density.

  • PDF

Structural and discharge characteristics of MgO films prepared by Arc Ion Plating (AIP) method

  • Kim, Jong-Kuk;Kim, Do-Geun;Lee, Eun-Sung;Lee, Sung-Hun;Lee, Gun-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.625-627
    • /
    • 2002
  • MgO thin films were deposited on glass and (100) Si substrates by an Arc Ion Plating (AIP) equipment using a magnesium metal target at various oxygen gas flow. In this work, we investigated the relationship between the structural properties and the discharge characteristics of MgO coating layers. X-ray diffraction and AFM have been used to study behaviors of the structure and surface morphology. The optical transmittance and the ion induced secondary electron emission coefficient of the MgO films have been also measured. The resistivity of the deposited MgO films was gradually increased from 0.17 G ohm/${\square}$ to 0.35 G ohm/${\square}$ with the oxygen gas flow. The growth rate of the MgO coating layer was decreased with increasing the oxygen gas flow, while the optical transmittance was improved.

  • PDF

고균일 유기박막 코팅을 위한 모세관 현상 전산모사 (Simulation of Capillary Phenomenon for Solution Coating of High-uniformity Organic thin Films)

  • 신동균;홍기영;박종운;서화일
    • 반도체디스플레이기술학회지
    • /
    • 제16권1호
    • /
    • pp.106-111
    • /
    • 2017
  • When a substrate with a pixel-defining layer (bank) is coated, there arises capillary force due to surface tension and adhesive forces between a solvent and the bank layer. It brings in a degradation of film thickness and emission uniformities within pixels. With an attempt to suppress it, we have performed fluid flow simulations of capillary arise by varying the contact angle of bank and the bank structure. We have first demonstrated that the fluid flow model can reproduce the capillary phenomenon that was observed experimentally. It has been found that capillary arise can be suppressed using a hydrophobic material for the bank layer. Furthermore, it was suppressed by tilting the sidewalls outwardly (i.e., using a positive photoresistor). We can obtain very uniform films when the slope is $50^{\circ}$ with the contact angle of $40^{\circ}$.

  • PDF

유연재 코팅 평판의 난류 변동압력 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Turbulent Wall Pressure Fluctuation Over Compliant Coatings)

  • 박경훈;이승재;신구균
    • 한국음향학회지
    • /
    • 제26권6호
    • /
    • pp.293-300
    • /
    • 2007
  • 수중운동체가 주행할 때 수중운동체의 표면에는 난류 경계층이 형성되고, 난류 경계층 내 벽면 변동압력은 탄성체인 수중운동체의 표면을 가진시켜 유동 유기 소음을 발생시킨다. 이러한 유체 소음을 감소시키기 위한 하나의 방법으로 수중운동체 표면에 유연재를 부착하여 수중운동체의 유동 유기 방사 소음을 감소시키는 방법이 제안되기도 한다. 본 논문에서는 유연재 부착에 따른 수중에서의 유체소음의 변화 특성을 살펴보기 위하여 유연재가 코팅되지 않은 강판 시편과, 고무 재질의 Neoprene 및 폴리우레탄 재질의 유연재가 부착된 강판시편을 저소음 공동수조에 설치한 후 여러 가지 유속 조건에서 유체소음의 주요 소음원인 난류 경계층 내 벽면 변동압력을 측정하고 그 결과를 비교 분석하였다. 그 결과 유연재를 코팅한 경우에는 유연재로 인하여 난류 경계층의 두께가 두꺼워지는 등 경계층 유동이 변화하지만, 유연재에서의 난류 에너지의 소산으로 인하여 고주파수 대역에서 약 10dB의 벽면 변동압력의 감소 효과를 확인할 수 있었다.