Flow and Heat Transfer Characteristics on Oblique Impingement Surface by Single Axisymmetric Jet (단일 축대칭제트에 의한 경사충돌면에서 유동 및 열전달 특성)

  • 이창호;황상동;조형희;정학재
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1999
  • An experimental study has been conducted to determine the effects of inclined impinging jet on the local heat transfer coefficients. A single jet with nozzle diameter of 24.6 mm was tested for Reynolds numbers from 10,000 to 70,000 and nozzle-to-plate spacings of 2~6 jet diameters. The angle of inclination of the impingement surface relative to the horizontal surface was varied from $0^{\cire}$ (normal impingement) to $60^{\cire}$. The results indicate that the point of maximum heat transfer is moved up from the geometrical stagnation point of inclined surface by Coanda effect. The local heat transfer coefficients on the minor jet region decrease more rapidly than on the major jet region, thus creating an imbalance in the cooling capabilities on the two sides.

  • PDF

Performance Improvement of a Scroll Compressor by Heat Transfer Analysis (열전달 해석을 통한 스크롤 압축기 성능 개선)

  • Hong, S. W.;Rew, H. S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.22-29
    • /
    • 2000
  • Numerical analysis using three dimensional finite volume method for the discretization, adaptive grid method for the numerical accuracy, multiple rotating frame method for the rotating body and the standard $k-{\epsilon}$ model for the turbulent flow was performed to understand the heat transfer phenomena and to improve the efficiency of the scroll compressor. The temperature measurement was carried out under ARI condition. It was found that the fluid temperature in the compressor was predicted accurately while the temperature of the motor coil showed large discrepancy between the calculation and experiment due to the large anisotropy of the conductivity and non homogeneity. We found that the efficiency of the compressor depends on the inlet temperature of the compressing part and the flow pattern around the inlet region of the compressing part influences the inlet temperature due to high surface temperature of the main frame. The efficiency of the compressor using Coanda effect is higher than the previous one because the smooth suction at the inlet region of the compressing part leads to low heat transfer to the refrigerant of the compressor.

  • PDF

Further results on the development of a novel VTOL aircraft, the Anuloid. Part II: Flight mechanics

  • Petrolo, Marco;Carrera, Erasmo;Visser, Coen de;D'Ottavio, Michele;Polit, Olivier
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.4
    • /
    • pp.421-436
    • /
    • 2017
  • This paper presents the main outcomes of the preliminary development of the Anuloid, an innovative disk-shaped VTOL aircraft. The Anuloid has three main features: lift is provided by a ducted fan powered by a turboshaft; control capabilities and anti-torque are due to a system of fixed and movable surfaces that are placed in the circular internal duct and the bottom portion of the aircraft; the Coanda effect is exploited to enable the control capabilities of such surfaces. In this paper, results from flight mechanics are presented. The vertical flight dynamics were found to be desirable. In contrast, the horizontal flight dynamics of the aircraft shows both dynamic instability, and more importantly, insufficient pitch and roll control authority. Some recommendations and guidelines are then given aimed at the alleviation of such problems.

A Study on the Interaction between Hull-Propeller and a High-Lifting Horn-type Rudder (선체-프로펠러와 고양력 혼타의 상호작용에 관한 연구)

  • Kim, Doo-Dong;Lee, Young-Gill
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.346-356
    • /
    • 2011
  • Rudder is to be located in extremely complicated flows generated and disturbed behind a hull and a propeller in operation. In order to estimate the rudder efficiency, it is quite important to investigate the disturbed flows due to the interaction under the hull-propeller and rudder condition. The purpose of the present research is to investigate the interaction between the hull-propeller and a high-lifting horn-type rudder through both numerical computations and experiments. A horn-type rudder implementing the Coanda effect of USB (Upper Surface Blowing) type is selected for its high efficiency of lifting force, and a 1/85 scaled model of 47K PC(Product Carrier) is manufactured for the purpose of the model test. The forces acting on the rudder during the experiment are measured using a three-component force gauge. Both cases are investigated in the hull-propeller-rudder condition and rudder open-water condition, which confirms that the flows generated under the former condition is considerably different from that of the latter condition.

Heat transfer and flow characteristics of sweeping jet issued from rectangular nozzle with thin plate (박판이 부착된 사각노즐에서 분사되는 Sweeping jet의 유동 및 열전달 특성)

  • Kim, Donguk;Jung, Jae Hoon;Seo, Hyunduk;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.58-66
    • /
    • 2019
  • This study investigated heat transfer and flow characteristics of a sweeping jet issued from a rectangular nozzle with a thin plate. A thin vertical aluminum plate was attached on outlet of fluidic oscillator to increase velocity of central area with Coanda effect and enhance heat transfer performance. From visualization and PIV experiments, sweeping jet with a thin plate has larger velocity distribution in center region than that of the normal sweeping jet while oscillating frequency is similar as the normal one. Thermographic phosphor thermometry method was used to visualize the temperature field and Nu distribution of plate with impinging sweeping jet with thin plate. Four Reynolds numbers and three jet-to-wall distances were selected as parameters. It is found that heat transfer performance in the low jet-to-wall spacing was enhanced as the cooled area was expanded. However, when the jet-to-wall spacing became greater than 8dh, heat transfer performance became similar due to reduced impinging velocity.

Characteristics of Entrainment Flow Rate in a Coanda Nozzle with or without Coaxial Contractor (코안다 노즐에서 중심 축소관 유무에 따른 유입량 특성)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2014
  • A MILD(Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow rate of hot exhaust gas to the combustion furnace. The present study used a coanda nozzle for the exhaust gas recirculation in a MILD combustor. A numerical analysis was accomplished to elucidate the effect of exhaust gas entrainment toward the furnace with or without a coaxial contractor. The result of the present CFD analysis showed that the entrainment mass flow rate without a coaxial contractor had 18% larger than that with a coaxial contractor when the mixed gas outlet pressure was ambient pressure. On the other hand, if the outlet pressure increased, the mass flow rate with a contractor was larger than that without a contractor. It could be analysed by the entrainment driving force composed with the nozzle throat pressure, inlet and outlet pressures and flow cross sectional area.

A Study of PIV Analysis around 2-Dimensional Foil with Blowing (물분사장치를 이용한 2차원 익 주위의 PIV 해석에 관한 연구)

  • Oh, Kyoung-Gun;Cho, Dae-Hwan;Lee, Gyoung-Woo;Ko, Jae-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.45-49
    • /
    • 2006
  • The flow around a foil with waterjet was investigated using the two-frame PIV(CACTUS 3.1) system. After separation, unsteady recirculation & reattachment region was shown as a result at reading edge. Separation area was decreased to 1/3 more by waterjet system with coanda effect. Angle of attack and waterjet velocity was a variable in the experiment. Each parameters was controlled to $0^{\circ}{\sim}35^{\circ}$ and 0[m/s]${\sim}$9.2[m/s]. The separation of flow appearanced at first when the angle of attack is $17^{\circ}{\sim}18^{\circ}$. However, according to grew up of velocity, beginning of the separation was delayed. In this experiment, vortex and separation region was disappeared by blown when each parameters are low level, and separation controlled more certainly.

  • PDF

A Numerical Study on a Circulation Control Foil using Coanda Effect (코앤다 효과를 이용한 순환 제어 날개의 수치적 연구)

  • J.J. Park;S.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.70-76
    • /
    • 2000
  • A numerical study on the viscous flow around a 2-dimensional circulation control foil is carried out for application on the field of naval architecture and ocean engineering. The governing equations are the RANS and the continuity equations. The equations are discretized by finite difference method and MAC method and the pressure poisson equation is calculate by a SOR method and an O-type non-staggered boundary fitted coordinate system which is overlapped near the slot is used to improve the numerical accuracy. Turbulence is approximated by a modified Baldwin-Lomax turbulence model. In the present paper, the Coanda effect on a 2-dimensional foil of a 20% thickness ellipse with modified rounded trailing edge has been numerically studied. The change in drag and lift of the foil with various jet momentums are calculated and compared to the experimental results to show good agreements.

  • PDF

Development of the High-Accuracy Multi-Component Balance for Fluidic Thrust Vectoring Nozzle of UAV (UAV용 유체역학적 추력편향 노즐의 고 정확도 다분력 시험장치 개발)

  • Song, Myung-Jun;Chang, Hong-Been;Cho, Yong-Ho;Lee, Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.142-149
    • /
    • 2013
  • The thrust vector control technique is essential for high maneuverability of unmanned aerial vehicles. In the present study, a multi-component balance was developed to quantitatively evaluate the thrust-vectoring performance of a supersonic rectangular nozzle based on the Coanda coflowing effect. Precise calibration and detailed data analysis were performed during the development. It was found that the cross-talk errors between load cells in the balance were less than 5%, and that the unwanted errors due to high-pressure supply tubes were almost negligible, which contributed to the high accuracy of the present balance design. Some preliminary test results of the thrust-vectoring performance of the present nozzle design were also obtained and analyzed.

A Study on Operation Characteristics of Co-flow Fluidic Thrust Vector Control under Over-expanded Jet Condition (동축류 이차유동 분사를 이용한 초음속 과팽창 제트유동의 유체역학적 추력방향제어 작동특성 연구)

  • Heo, Jun-Young;Jeon, Dong-Hyun;Lee, Yeol;Sung, Hong-Gye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.416-423
    • /
    • 2011
  • The purpose of this research is to investigate the operation characteristics of fluidic thrust vector control using injection of the control flow parallel to the main jet direction; Co-flow injection. The technique bases on the Coanda effect of flow. Both numerical and experimental studies were conducted to investigate operation parameters; flow structure, the jet deflection angle, and shock effects near the nozzle exit. While the total pressure of main jet is the range of 300 to 790 kPa, the total pressure of control flow varies from 120 to 200 kPa. The jet deflection angle and thrust coefficient have linear relation with the pressure ratio(PR) of main jet to control flow in 0.15 < PR < 0.4 but show their limit above PR = 0.4.