A study on fundametal properties of thermoelectric power plant pond-ash in Korea (국내 화력발전소 매립회의 기초물성에 관한 연구)

  • Lee, Bong-Chun;Jung, Sang-Hwa;Kim, Jin-Sung;Kim, Joo-Hyung;Moon, Jae-Heum;Kim, Tae-Sang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.841-844
    • /
    • 2008
  • Non-refining fly ash and bottom ash, the byproducts generated from the coal-fired power stations, have usually been disposed of in onshore ash disposal sites. With an increase of power consumption due to industrial development, the generation of coal ash has been growing tremendously. Current insufficiency of disposal sites and environmental concerns over newly-built disposal sites have also led a growing need to utilize the coal ash. Accordingly, this paper compares and analyzes the fundamental properties of the coal ash collected from each disposal sites in order to increase the usability of the coal ash generated from coal-fired power stations. The results of the study indicate that coal ash shall be separately applied by the properties for each intended use as the ash greatly differs in its properties depending on the site of disposal. In particular, it is shown that the overall evaluation on the ash shall be necessary as the quality might be varied by the change of absorptance when applied as an aggregate for concrete. From the examination on the salt content, it has been observed that the ash can be applied as an aggregate for concrete only after more than 3 times of washing process.

  • PDF

The Effect of Multi-Coal Combustion on the Generation of Slagging in a Bituminous Coal-fired Power Plant Boiler (연탄 화력발전소 보일러에서 다탄종 연소가 슬래깅 발생에 미치는 영향)

  • Park, Jihoon;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • In this study, I analyzed the effect of slagging caused by blending bituminous coal and subbituminous coal while maintaining the generator output, combustion conditions, and ventilation conditions for 870MW thermal power plant designed with bituminous coal. Accordingly I proposed an acceptable method of blending coal method. the blending ratio of sub-bituminous coal was adjusted to 10%, 20%, 40%, 60%, 80%, etc. to confirm ultimate analysis, proximate analysis, ash fusion temperature change, slagging indices, etc. Proper blending coal conditions are blending with sub-bituminous coal at 40% or less, ratio of base component to acid component(B/A) is 0.4 or less or 1 or more, total alkali(TA) is 3.5 or less, fusion slagging index(Rfs) is 1,345℃ or more, and ash content is 13% or less in ultimate analysis, the ash content in proximate analysis is 15% or less, and the initial deformation temperature(IDT) should be at least 1,200℃ or more

  • PDF

Abnormal Vibration of the Steam Turbine Shaft in 500 MW Class Coal-fired Power Plants (500 MW급 석탄화력발전소 증기터빈축 이상진동의 해결방안)

  • Ahn, Kwang-Min;Yoo, HoSeon
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • During the start-up of 500 MW class coal-fired power plant, abnormal shaft vibration was occurred on bearings installed on both side of high and intermediate pressure steam turbine. Shaft vibration was analyzed to investigate the reason and find the resolution, based on well-known theory in this study. Typical vibration characteristics which occur when rotating parts contact with stationary parts were observed at the analysis of frequency, amplitude and phase angle. The reason of abnormal vibration was assumed to be rub and internal parts wear was observed during repair period. As a result of applying low speed turning and balancing for resolution of abnormal vibration, balancing was more effective for rub removal. So balancing could be excellent resolution in the case of abnormal vibration which is similar to this study.

  • PDF

The Study on the ECO Artificial Precast Block using Coal-ash (석탄회를 이용한 환경친화적 프리캐스트 블록의 개발)

  • 조병완;권병윤;박승국;김진일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.1015-1020
    • /
    • 2002
  • Recycling of coal combustion by-product(Ash) are becoming more improtant in the utilization business as a result of the increased use of NOx reduction technologies at coal-fired power plants. Current disposal methods of these by-products create not only a loss of profit for the power industry, but also environmental concerns that breed negative public opinion. This research made Precast block for environment-friendly secondary product and compare strength special quality of this block with existent common use brick and analyze application possibility in situ with a reserve experiment that measure strength property and manufacture method to handle coal ash produced in Bo-ryung thermoelectric power plant.

  • PDF

CO2 sequestration and heavy metal stabilization by carbonation process in bottom ash samples from coal power plant

  • Ramakrishna., CH;Thriveni., T;Nam, Seong Young;kim, Chunsik;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.74-83
    • /
    • 2017
  • Coal-fired power plants supply roughly 50 percent of the nation's electricity but produce a disproportionate share of electric utility-related air pollution. Coal combustion technology can facilitate volume reduction of up to 90%, with the inorganic contaminants being captured in furnace bottom ash and fly ash residues. These disposal coal ash residues are however governed by the potential release of constituent contaminants into the environment. Accelerated carbonation process has been shown to have a potential for improving the chemical stability and leaching behavior of bottom ash residues. The aim of this work was to quantify the volume of $CO_2$ that could be sequestrated with a view to reducing greenhouse gas emissions and stabilize the contaminated heavy metals from bottom ash samples. In this study, we used PC boiler bottom ash, Kanvera reactor (KR) slag and calcined waste lime for measuring chemical analysis and heavy metals leaching tests were performed and also the formation of calcite resulting from accelerated carbonation process was investigated by thermo gravimetric and differential thermal analysis (TG/DTA).

Studies on the Combustion Characteristics and NO Distribution in the Pulverized Coal Fired Boiler (대용량 미분탄 보일러의 연소특성 및 NO 분포 특성 연구)

  • Park, Ho-Young;Kim, Young-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.552-559
    • /
    • 2008
  • Three dimensional numerical analysis were performed to investigate the combustion characteristics in a tangentially fired pulverized coal boiler. The predicted values at the outlet of economizer for the gas temperature, O$_2$, NO, CO were been compared with the measured data. By using the actual operating conditions of the power plant, the distribution of velocity, gas temperature, O$_2$, CO, CO$_2$ and NO as well as the particle tracking in the boiler were investigated. Throughout the present study, the non-uniform distribution of flue gas temperature in front of the final superheater might be resulted from the residual swirl flow in the upper furnace of the boiler. The present analysis on non-uniform distribution of the gas temperature could provide the useful information to prevent the frequent tube failure from happening in the final superheater of the tangentially coal-fired boiler.

Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack (화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증)

  • Shin, Dongho;Kim, Young-Hoon;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Lee, Ga-Young;Chun, Sung-Nam;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

Effect of activated carbon on bloating properties of artificial lightweight aggregates containing coal reject ash and bottom ash (석탄 잔사회 및 바닥재가 포함된 인공경량골재의 발포특성에 미치는 활성탄소의 영향)

  • Kang, Min A;Kang, Seunggu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • The coal bottom ash and reject ash discharged from a coal-fired power plant are difficult to recycle so most of them are mainly landfill-disposed. In this study, the artificial aggregate were produced using reject ash, bottom ash and dredged soil emitted from the coal-fired power plant in Korea and the effect of experimental factors on the bloating behavior and the properties of the aggregates were analyzed. In particular, a lot of unburned carbon in the reject ash was removed by calcination and the activated carbon was added to batch powders then the dependence of those process upon bloating properties of artificial aggregate were investigated. For this purpose, the specific gravity and water absorption values of artificial aggregates were investigated in conjunction with microstructural observations. This study could contribute to increase the recycling rate of the reject ash.

A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler (870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰)

  • Woo, Gwang-Yoon;Kim, Soo-Seok;Park, In-Chan;Ham, Young-Jun;Lee, Eung-Yoon
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • In this study, the boiler efficiency and the change of boiler combustion state with the burner operation of the uppermost layer of 870MW opposite fired coal boiler were measured. Test results showed that the boiler efficiency was high in the order of the uppermost layer simultaneous operation of the front and rear burners, the front burner, and the rear burner operation. When the front and rear burners were operated simultaneously, the heat absorption rate of water walls in the boiler furnace was uniform at four side, and the temperature deviation of the left and right steam on the convection front surface decreased. As the heat absorption rate of the boiler improved, the loss of boiler exhaust gas decreased and the coal supply amount decreased by 8 tons/hour compared to the operation of the rear burner. This will contribute not only to the reduction of fuel cost but also to the reduction of greenhouse gas emissions.