Studies on the Production of Artificial Zeolite from Coal Fly Ash and Its Utilization in Agro-Environment

  • Lee, Deog-Bae;Henmi, Teruo;Lee, Kyung-Bo;Kim, Jae-Duk
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.401-418
    • /
    • 2000
  • 1. Production of the artificial zeolite from coal ash Coal fly ash is mainly composed of several oxides including $SiO_2$ and $Al_2O_3$ derived from inorganic compounds remained after burning. As minor components, $Fe_2O_3$ and oxides of Mg, Ca, P, Ti (trace) are also contained in the ash. These components are presented as glass form resulting from fusion in the process of the combustion of coal. In other word, coal ash may refer to a kind of aluminosilicate glass that is known to easily change to zeolite-like materials by hydrothermal reaction. Lots of hot seawater is disposing near thermal power plants after cooling turbine generator periodically. Using seawater in the hydrothermal reaction caused to produce low price artificial zeolite by reduction of sodium hydroxide consumption, heating energy and water cost. As coal ash were reacted hydrothermally, peaks of quartz and mullite in the ash were weakened and disappeared, and new Na-Pl peaks were appeared strengthily. Si-O-Si bonding of the bituminous coal ash was changed to Si-O-Al (and $Fe^{3+}$) bonding by the reaction. Therefore the produced Na-Pl type zeolite had high CEC of 276.7 $cmol^+{\cdot}kg^{-1}$ and well developed molecular sieve structure with low concentration of heavy metals. 2. Utilization of the artificial zeolite in agro-environment The artificial zeolite(1g) could remove 123.5 mg of zinc, 164.7 mg copper, 184.4 mg cadmium and 350.6 mg lead in the synthetic wastewater. The removability is higher 2.8 times in zinc, 3.3 times in copper, 4.7 times in cadmium and 4.8 times in lead than natural zeolite and charcoal powder. When the heavy metals were treated at the ratio of 150 $kg{\cdot}ha^{-1}$ to the rice plant, various growth inhibition were observed; brownish discoloration and death of leaf sheath, growth inhibition in culm length, number of panicles and grains, grain ripening and rice yield. But these growth inhibition was greatly alleviated by the application of artificial zeolite, therefore, rice yield increased $1.1{\sim}3.2$ times according to the metal kind. In addition, the concentration of heavy metals in the brown rice also lowered by $27{\sim}75%$. Artificial Granular Zeolites (AGZ) was developed for the purification of wastewater. Canon exchange capacity was 126.8 $cmol^+{\cdot}kg^{-1}$. AGZ had Na-Pl peaks mainly with some minor $C_3S$ peaks in X-ray diffractogram. In addition, AGZs had various pore structure that may be adhere the suspended solid and offer microbiological niche to decompose organic pollutants. AGZ could remove ammonium, orthophosphate and heavy metals simultaneously. Mixing ratio of artificial zeolite in AGZs was related positively with removal efficiency of $NH_4\;^+$ and negatively with that of $PO_4\;^{3-}$. Root growth of rice seedling was inhibited severely in the mine wastewater because of strong acidity and high concentration of heavy metals. As AGZ(1 kg) stayed in the wastewater(100L) for 4days, water quality turned into safely for agricultural usage and rice seedlings grew normally.

  • PDF

Apparatus for Measuring Fan Stall of Boiler for Power Station (화력발전용 보일러의 맥동 측정 장치)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1681-1684
    • /
    • 2014
  • In this paper, in the ventilation system of coal-fired power boilers can measure in real time the fan stall mechanism is all about. The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

A Study on the Improved the Hydrophobicity of Torrefied Biomass (반탄화 과정을 통한 바이오매스의 소수성 개선 연구)

  • JEONG, JAE-SEONG;KIM, GYEONG-MIN;JEONG, HYUN-JUN;KIM, GYU-BO;JEON, CHUNG-HWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2019
  • Biomass, a carbon-neutral fuel, has great advantages because it can replace fossil fuels to reduce greenhouse gas emissions. However, due to its low density, high water content, and hydrophilicity, biomass has disadvantages for transportation and storage. To improve these properties, a pretreatment process of biomass is required. One of the various pre-treatment technologies, torrefacion, makes biomass similar to coal through low-temperature pyrolysis. In this study, torrefacion treatment was carried out at 200, 230, 250, 280, and $300^{\circ}C$ for wood pellet, empty fruit bunch (EFB) and kenaf, and the feasibility of replacing coal with fuel was examined. Hygroscopicity tests were conducted to analyze the hydrophobicity of biomass, and its chemical structure changes were investigated using Infrared spectrum analysis. It was confirmed that the hygroscopicity was decreased gradually as the torrefacion temperature increased according to the hygroscopicity tests. The hydrophilicity was reduced according to the pyrolysis of hemicellulose, cellulose, and lignin of biomass.

Adsorption Characteristics of Sr(II) and Cs(I) ions by Zeolite Synthesized from Coal Fly Ash (Coal Fly Ash로 합성한 제올라이트에 의한 Sr(II)과 Cs(I) 이온의 제거 특성)

  • Lee, Chang-Han;Park, Jeong-Min;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1987-1998
    • /
    • 2014
  • Zeolite was synthesized from power station waste, coal fly ash, as an alternative low-cost adsorbent and investigated for the removal of Sr(II) and Cs(I) ions from single- and binary metal aqueous solutions. In order to investigate the adsorption characteristics, the effects of various operating parameters such as initial concentration of metal ions, contact time, and pH of the solutions were studied in a batch adsorption technique. The Langmuir model better fitted the adsorption isotherm data than the Freundlich model. The pseudo second-order model was found more applicable to describe the kinetics of system. The adsorption capacities of Sr(II) and Cs(I) ions obtained from the Langmuir model were 1.7848 mmol/g and 0.7640 mmol/g, respectively. Although the adsorption capacities of individual Sr(II) and Cs(I) ions was less in the binary-system, the sum of the total adsorption capacity (2.3572 mmol/g) of both ions in the binary-system was higher than the adsorption capacity of individual ion in the single-system. Comparing the homogeneous film diffusion model with the homogeneous particle diffusion model, the adsorption was mainly controlled by the particle diffusion process.

Combustion Characteristics of Coal-Fired Boiler Depending on the Variations in Combustion Air Supply Method (미분탄 보일러의 연소용 공기공급 변화에 따른 노내 연소상태 해석)

  • Seo, San-Il;Park, Ho-Young;Kang, Dong-Soo;Jeong, Dong-Hae
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.156-162
    • /
    • 2010
  • 3-D CFD(Computational Fluid Dynamics) work were carried out to investigate the combustion characteristics in a boiler depending on the variations in air supply condition. For the gas temperature, $O_2$, NO, SOx at the outlet of economizer, the predicted values were been compared with the measured data. With the verified CFD model, the effects of air flow rates through SOFA(Separated Over Fire Air) and CCOFA(Closed Coupled Over Fire Air) on the combustion behavior in a boiler were simulated, and the distributions of NOx and gas temperature were mainly compared each other. The change in SOFA air flow rate gave the more sensitive effect on NOx than that in CCOFA. The distributions of gas temperature at convection path are differed with the changes in SOFA and CCOFA flow rate, so the combustion modification such as yaw anlge adjustment are required to get an enhanced gas temperature distribution.

A Study on the Performance Improvement for The Coal Filing Power Station (엑서지분석을 통한 대용량 석탄화력 발전소의 성능개선 연구)

  • 서주오
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.165-176
    • /
    • 2003
  • In this study, the exergy analysis is conducted on the well known performance of already developed system and then compared with the efficiency of each equipment to propose optimum operation of the system. The system used in this study is 500 MW coal firing power plant. The efficiency of the boiler is 67% and the condenser is 99% by exergy analysis. The exergy consumption of the boiler was 32.95% at 100% load. The exergy consumption of the high pressure turbine and the low pressure turbine is 8.31% and 8.12%, respectively. Together with the concrete study on the object of performance revision of the low efficient development system proved in this study, if detailed exergy analysis on the operation condition of the equipments of the development system presently being operated is continued, then it is expected to help minimize the exergy consumption of relatively low efficient parts that are worn-out or miss-installed.

A Case Study of Desulphurization by Limestone Adsorbent in an Industrial CFBC Boiler

  • Park, Young-Goo;Kim, Seung-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.67-74
    • /
    • 2005
  • Domestic anthracite contains a large amount of fine particles, which causes to fire the back side of the boiler and to form the clinker deteriorating the combustion efficiency. At this time, the fine limestone adsorbents for a desulphurization agent may be used to facilitate an aggravation of the boiler, so that fine mode of limestone (<0.1mm) has been used no more than $25\%$ in local power stations of Korea. The present test carried out with an in-situ boiler, however, showed that higher content $(up\;to\;50\%)$ of fine limestone particles did not entail any mal-function. In addition, the desulphurization was found to be as good as the old mode of limestone adsorbents.

The Kwinana Shoreline Fumigation Experiment in Western Australia, Australia

  • Yoon, I.H.;Sawford, B.L;Manins, P.C.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1996.04a
    • /
    • pp.22-22
    • /
    • 1996
  • ;The Kwinana Shoreline Fumigation Experiment(KSFE) took place in Fremantle, WA, Australia between 23 January and 8 February, 1995. All measurement systems performed to expectation. The CSIRO DAR(Division of Atmospheric Research) LIDAR measured plume sections from near the Kwinana Power Station(KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. Radiosonde and double theodolite sounding systems measured temperature, humidity, air pressure and wind structure at the coast(Woodman Point) and at the inland(ALCOA residue dump) site at intervals of roughly two hours. These were supplemented by mid afternoon soundings(radiosonde and single theodolite) by Department of Environmental Protection(DEP) at Swanbourne. The Flinders aircraft measured wind, turbulence and temperature structure of the atmospheric boundary layer, concentrations of $C0_2,\;0_3,\;S0_2\;and\;NO_x$ in the smoke plumes and surface radiation over both land and sea. CSIRO DCET(Division of Coal and Energy Technology) vehicle successfully interceptde many smoke plumes and using a range of tracers will be able to identify the various sources much of the time. Routine data from the DEP and Kwinana Industrial Council(KIC) air quality monitoring networks were also automatically logged. Murdoch University measured surface heat flux at Hope Valldy monitoring station and also at Wattleup monitoring station for the last five days. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminumgarnet(Nd:Y AG) laser operating at a fundamental wavelength of 1064 nm, with harmonics fo 532 nm and 355 nm. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detedted by a photomultiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The results of nine days special field observations are summarized in detail.etail.

  • PDF

Development of Light Transmission Fluctuation for Particle Measurement in Solid-Gas Two Phase Flows

  • YANG, Bin;WANG, Zhan-ping;HE, Yuan;CAI, Xiao-Shu
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • In order to realize In-line and convenient measurement for solid-gas two phase flows, Light Transmission Fluctuation (LTF) based on the random variation of transmitted light intensity, light scattering theory and cross-correlation method was presented for online measurement of particle size, concentration and velocity. The statistical relationship among transmitted light intensity, particle size and particle number in measurement zone was described by Beer-Lambert Law. Accordingly, the particle size and concentration were determined from the fluctuation signal of transmitted light intensity. Simultaneously, the particle velocity was calculated by cross-correlation analysis of two neighboring light beams. By considering the influence of concentration variation in industrial applications, the improved algorithm based on spectral analysis of transmitted light intensity was proposed to improve measurement accuracy and stability. Therefore, the online measurement system based on LTF was developed and applied to measure pulverized coal in power station and raw material in cement plant. The particle size, concentration and velocity of powder were monitored in real-time. It can provide important references for optimal control, energy saving and emission reduction of energy-intensive industries.

Developing and Assessing Geopolymers from Seochun Pond Ash with a Range of Compositional Ratios (서천화력발전소 매립 석탄재로부터 제조한 다양한 조성비의 지오폴리머와 그 특성의 평가)

  • Lee, Sujeong;Jou, Hyeong-Tae;Chon, Chul-Min;Kang, Nam-Hee;Cho, Sung-Baek
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.2
    • /
    • pp.134-141
    • /
    • 2013
  • Pond ash produced from Seochun Power Station was quantitatively characterized to manufacture geopolymers with a range of Si/Al compositional ratios. Mix consistency was kept nearly constant for comparing the compressive strengths of geopolymers. The amorphous composition of coal ash was determined using XRF and quantitative X-ray diffraction. Different mix compositions were used in order to achieve Si/Al ratios of 2.0, 2.5 and 3.0 in the geopolymer binder. Geopolymers synthesized from coal ash with a Si/Al ratio of 3.0 exhibited the highest compressive strength in this study. It was found that geopolymers activated with aluminate produced different microstructure from that of geopolymers activated with silicate. High silica in alkali activators produced the fine-grained microstructure of geopolymer gel. It was also found that high compressive strength was related to low porosity and a dense, connected microstructure. The outcome of the reported experiment indicates that quantitative formulation method made it possible to choose suitable activators for achieving targeted compositions of geopolymers and to avoid efflorescence.