Browse > Article

A Study on the Performance Improvement for The Coal Filing Power Station  

서주오 (한국동서발전(주) 당진화력)
Publication Information
Abstract
In this study, the exergy analysis is conducted on the well known performance of already developed system and then compared with the efficiency of each equipment to propose optimum operation of the system. The system used in this study is 500 MW coal firing power plant. The efficiency of the boiler is 67% and the condenser is 99% by exergy analysis. The exergy consumption of the boiler was 32.95% at 100% load. The exergy consumption of the high pressure turbine and the low pressure turbine is 8.31% and 8.12%, respectively. Together with the concrete study on the object of performance revision of the low efficient development system proved in this study, if detailed exergy analysis on the operation condition of the equipments of the development system presently being operated is continued, then it is expected to help minimize the exergy consumption of relatively low efficient parts that are worn-out or miss-installed.
Keywords
Citations & Related Records
연도 인용수 순위
  • Reference
1 Understanding Combustion Irreversibility /
[ Dunbar,W.R.;Lior,N. ] / ASME AES-Vol 25/HTD
2 Second law analysis of the turbine cycle for steam power plants:a parametric study /
[ Tsung,S.M. ] / Ph. D. Thesis
3 A practical exergy method for system analysis /
[ Feng Xiao;Zhu,X.X.;Zheng,J.P. ] / 31th IECEC
4 /
[ Ahem,J.E. ] / The Exergy Method of Energy Systems Analysis
5 /
[] / 한국전력통계
6 /
[ Obert,E.F.;Gaggioli,R.A. ] / Thermodynamics(2nd ed.)
7 /
[ Bejan,A.;Tsatsaronis,G.;Moran,M. ] / Thermal Design & Optimization
8 /
[ 조형래;홍은기;황광원 ] / 신규화력 발전설비 인수성능 시험결과 보고서
9 /
[ Keenan,J.H. ] / Themodynamics
10 /
[ Moran,M.J. ] / Availability Analysis:A Guide to Efficiency Energy Use
11 /
[ Moran,M.J.;Shapiro,H.N. ] / Fundamentals of Engineering Thermodynamics
12 /
[ Haywood,R.W. ] / Equilibrium Thermodynamics for Engineers and Scientists