• Title/Summary/Keyword: Co-simulator

Search Result 348, Processing Time 0.032 seconds

Reactor Sizing for Hydrogen Production from Ethane over Ni Catalyst (니켈 촉매 상에서 에탄으로부터 수소생산을 위한 반응기 사이징)

  • Seong, Minjun;Lee, Kyungeun;Cho, Jung-Ho;Lee, Young-Chul;Jeon, Jong-Ki
    • Clean Technology
    • /
    • v.19 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • In this study, kinetics data was obtained for steam reforming reaction of ethane over the nickel catalyst. The variables of steam reforming reaction were reaction temperature, partial pressure of ethane, and mole ratio of steam and ethane. Parameters for the power rate law kinetic model and the Langmuir-Hinshelwood model were obtained from the kinetic data. Also, sizing of steam reforming reactor was performed by using PRO/II simulator. For the steam reforming reaction of ethane, Langmuir-Hinshelwood model determining the reaction rate by the surface reaction was better suited than a simple power rate law kinetic model. On water-gas-shift reaction, power rate law kinetic model was well fitted to the kinetic data. Reactor size can be calculated for production of hydrogen through PRO/II simulation.

Centrifuge Test for Earthquake Response of Structures with Basements (지하층이 있는 구조물의 지진응답을 위한 원심모형실험)

  • Kim, Dong Kwan;Park, Hong Gun;Kim, Dong Soo;Ha, Jeong Gon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.223-234
    • /
    • 2016
  • To investigate earthquake responses of structures with basements affected by soil deposits, centrifuge tests were performed using an in-flight earthquake simulator. The test specimen was composed of a single-degree-of-freedom structure model, a basement and sub-soil deposits in a centrifuge container. The test parameters were the dynamic period of the structure model, boundary conditions of the basement, existence of soil deposits, centrifugal acceleration level, and type and level of input earthquake accelerations. When soil deposits did not exist, the earthquake responses of the structures with fixed basement were significantly greater than those of the structure without basement. Also, the earthquake responses of the structures with the fixed basement surrounded by soil deposits were amplified, but the amplifications were smaller than those of the structures without basement. The earthquake responses of the structures with the half-embedded basement in the soil deposits were greater than those estimated by the fixed base model using the measured free-field ground motion. The test showed that the basement and the soil deposit should be simultaneously considered in the numerical analysis model, and the stiffness of the half-embedded was not effective.

A Study on Evacuation Safety of Trainingship HANBADA using FDS & maritimeEXODUS

  • KIM, Won-Ouk;HAN, Ki-Young;KIM, Dae-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.3
    • /
    • pp.266-272
    • /
    • 2017
  • In this study, it was simulated and analyzed the evacuation safety to identify the cadets' evacuation time by using maritimeEXODUS which is applied IMO MSC.1/Circ.1238 theory as well as the trim and heel which are the major factor of reducing the ship evacuation speed. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. As a result of the analysis on visibility evacuation limit 5 m, it was found that the only one evacuation rallying point could not meet the evacuation safety. However, it derived the perfect evacuation safety under the condition of two rallying points available on wood fire. In case of Kerosene, it was satisfied the evacuation safety if the heeling was under $10^{\circ}$. Moreover, it could not meet the evacuation safety by evacuating through upper deck although there were two evacuation rallying points. When it was set by the lifeboat descending maximum angle-$20^{\circ}heel$ and $10^{\circ}trim$ which was described in SOLAS regulation, it was simulated that the wood fire having two evacuation rallying points in the center of the ship satisfied the evacuation safety.

Modeling, Simulation and Optimization of Hydrogen Production Process from Glycerol using Steam Reforming (글리세롤로부터 수증기 개질에 의한 수소 생산공정의 모델링, 시뮬레이션 및 최적화)

  • Park, Jeongpil;Cho, Sunghyun;Lee, Seunghwan;Moon, Dong Ju;Kim, Tae-Ok;Shin, Dongil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.727-735
    • /
    • 2014
  • For improved sustainability of the biorefinery industry, biorefinery-byproduct glycerol is being investigated as an alternate source for hydrogen production. This research designs and optimizes a hydrogen-production process for small hydrogen stations using steam reforming of purified glycerol as the main reaction, replacing existing processes relying on steam methane reforming. Modeling, simulation and optimization using a commercial process simulator are performed for the proposed hydrogen production process from glycerol. The mixture of glycerol and steam are used for making syngas in the reforming process. Then hydrogen are produced from carbon monoxide and steam through the water-gas shift reaction. Finally, hydrogen is separated from carbon dioxide using PSA. This study shows higher yield than former U.S. DOE and Linde studies. Economic evaluations are performed for optimal planning of constructing domestic hydrogen energy infrastructure based on the proposed glycerol-based hydrogen station.

Design of a Multi-Stripline Loaded On-Glass Antenna for T-DMB Applications (다중 선로가 로딩된 T-DMB 수신용 차량 글래스 안테나 설계)

  • Kang, Woo-Joong;Kay, Young-Chul;Park, Seul-Gi;Oh, Jung-Hun;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.664-672
    • /
    • 2009
  • In this paper we propose an on-glass antenna which consists of conducting dual center striplines and multi-loaded striplines. Multi-loaded striplines and dual center lines were employed for achieving a broad matching bandwidth and improving a vertical radiation gain, respectively. The detail design parameters were determined using the Pareto genetic algorithm with an full wave EM simulator. The optimized design was built and installed on a commercial vehicle, and the antenna performances such as the return loss and the radiation gain were measured in a semi-anechoic chamber. The measurement results showed the matching bandwidth($S_{11}$<-3 dB) of about 49 % in the T-DMB frequency band, the vertical gain of about -3 dBi along the bore-sight direction, and the average gain of about -10 dBi along the azimuth direction.

The effect of communication quality on team performance in digital main control room operations

  • Kim, HyungJun;Kim, Seunghwan;Park, Jinkyun;Lee, Eun-Chan;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1180-1187
    • /
    • 2020
  • A team of operators is required for nuclear power plant operation, and communication between the operators is an important aspect of the team's ability to successfully carry out tasks. It has been difficult to evaluate the quality of this communication though, and as the relationship between communication quality and team performance has yet to be clarified, it has not been applied to most human reliability analysis (HRA) methodologies. This study investigates the relationship between the quality of communication and team performance using data from a full-scope training simulator of a digital main control room (MCR). Two important characteristics of communication were considered to determine quality: each operator's ability to self-confirm the status of a given task in a digital MCR, and the type of communication, as divided into 1-way, 2-way, and 3-way between operators. To measure team performance, the concept of an unsafe act was employed, which is defined as a human error that has the potential to negatively affect plant safety. Analysis results showed that the communication quality and team performance were related to each other. With this more clearly defined relationship, the results of this study can be applied to related performance shaping factors to improve HRA.

Design of Source Driver for QVGA-Scale LDI Using Mixed Driving Method (Mixed Driving 방식을 이용한 QVGA급 LDI의 Source Driver 설계)

  • Kim, Hak-Yun;Ko, Young-Keun;Lee, Sung-Woo;Choi, Ho-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.11
    • /
    • pp.40-47
    • /
    • 2009
  • In this paper, we present the design of a source driver of QVGA scale TFT-LCD driver IC which uses a mixed driving method and performs $\gamma$-correction to improve image. The source driver with 240 RGB ${\times}$ 320 dots resolution drives a TFT-LCD panel through 720 channels and implements 262k colors using 18-bit RGB data format. The mixed driving method is a mixture the channel amp. driving method with high drivability and the gray amp. driving method with small area, which remarkably reduces channel driver areas. The driver has been designed using the $0.35{\mu}m$ Magnachip embedded DRAM technology and simulated using the HSPICE simulator. The results show that our source driver operates well with y-correction and the channel driver has $17{\mu}s$ channel driving time with only 78 driving amplifiers and control logic.

Integrated Control Algorithm of Hydraulic Pump with Electric Motor to Improve Energy Efficiency of Electric Excavator (전기굴삭기 에너지 효율 향상을 위한 유압펌프-전동기 통합 제어 알고리즘)

  • Lee, Jeeho;Lee, Jihye;Lee, Hyeongcheol;Oh, Chang Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.195-201
    • /
    • 2015
  • An electric excavator consumes battery energy to drive an electric motor attached to a hydraulic pump to generate hydraulic power. In a conventional hydraulic excavator, the hydraulic pump is controlled by regulators, which are used to optimize the diesel engine efficiency. Because of a lack of battery energy capacity, an electric excavator controller should consider not only the electric motor efficiency but also the hydraulic pump efficiency. Thus, electric motor and hydraulic pump efficiency maps were constructed. An optimal operating map (OOM) was created based on the most efficient operating points under each input condition. An integrated control algorithm controlled the speed of the electric motor and displacement of the hydraulic pump according to the OOM. To confirm the utility of this algorithm, a model-in-the-loop simulator for the algorithm with an electric excavator was established. The simulation results showed that the integrated control algorithm improved the energy efficiency of an electric excavator.

Fabrication of Analysis Tool for Performance Verification of Naval Multi Function Radar (함정용 다기능레이다 성능검증을 위한 분석도구 제작)

  • Choi, Hong-Jae;Park, Myung-Hoon;Riew, oo-Gon;Kwon, Sewoong;Lee, Ki-Won;Kang, Yeon-Duk;Yo, Seung-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.123-131
    • /
    • 2020
  • The system performance of naval multi function radar is affected by radar beam operation. Multi f function radar has to operate complicated beam better than search radar and tracking radar which have single operation. This paper describes fabricating analysis tool for the verification method for system performance of naval multi function radar. We composed the model that naval ship with MFR and radar which are detecting targets to verification the system performance. The targets are composed anti-aircraft and anti-ship. We integrate each model and make naval MFR simulator that applied resource management of track beam and search beam. We verify analysis tool by simulation in operating scenario after adjusting system parameter to analysis tool.

Fabrication and Characterization of Low Noise Amplifier using MCM-C Technology (MCM-C 기술을 이용한 저잡음 증폭기의 제작 및 특성평가)

  • Cho, H.M.;Lim, W.;Lee, J.Y.;Kang, N.K.;Park, J.C.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.11a
    • /
    • pp.61-64
    • /
    • 2000
  • We fabricated and characterized Low Noise Amplifier (LNA) using MCM-C (Multi-Chip-Module-Cofired) technology for 2.14 GHz IMT-2000 mobile terminal application. First, We designed LNA circuits and simulated it's high frequency characteristics using circuits simulator. For the simulation, we adopted high frequency libraries of all the devices used in LNA samples. By the simulation, Gain was 17 dB and Noise Figure was 1.4 dB. We used multilayer process of LTCC (Low Temperature Co-fired Ceramics) substrate and conductor, resistor pattern for the MCM-C LNA fabrication. We made 2 buried inductors, 2 buried capacitors and 3 buried resistors. The number of the total layers was 6. On the top layer, we patterned microstrip line and pads for the SMT device. We measured the high frequency characteristics, and the results were 14.7 dB Gain and 1.5 dB Noise Figure.

  • PDF