• 제목/요약/키워드: Co-injection Molding

검색결과 142건 처리시간 0.024초

DNA 검출 공정 전용 플라스틱 튜브형 시험관 개발에 관한 연구 (A study on development of plastic vial tube for the DNA detection process)

  • 최규완;라문우;강정희;장성호
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.35-40
    • /
    • 2017
  • PCR(Polymerase chain reaction) is a technique to replicate and amplify a desired part of DNA. It is used in various aspects such as DNA fingerprint analysis and rare DNA amplification of an extinct animal. Especially in the medical diagnosis field, it provides various measurement methods at the molecular level such as genetic diagnosis, and is a basic tool for molecular diagnostics. The internal shape of the plastic vial tube for PCR analysis used in the DNA detection process, and the surface roughness and internal cleanliness can affect detection and discrimination results. The plastic vial tube demanded by the developer of the PCR analysis equipment should be changed to a structure that eliminates the residual washing solution in the washing process to ensure the internal cleanliness. Thus the internal structure and the internal surface design for improving the PCR amplification efficiency are key issues to develop the plastic vial tube for the DNA detection process.

비구면 프리즘 렌즈를 이용한 소형 경량의 EGD용 광학계 설계 및 제작 (Aspherical prism lens design and manufacture of a small size and light wight EGD)

  • 김태하;박광범;김미정;박영수;김휘운;문현찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.454-454
    • /
    • 2007
  • Eye Glass Display (EGD) with microdisplay to realize the virtual display can make the large screen, so virtual image has been developed by using microdisplay panel. This paper shows study of spherical prism lens design and manufacture of a small size and light weigh EGD with 0.59" OLED panel. Code V is used and it designed an aspherical prism lens about eye relief 25mm and 42 degree of filed of view (FOV). With the application this aspheric prism lens to OLED type's microdisplay, virtual image showed 60 inch at 2m. It had less than 2% of distortion value and modulation transfer function in axial had 30% of resolution with 32 lp/mm spatial frequency. We made an injection molding bases to lens designed.

  • PDF

초음파 접합 공정을 합성한 자동차용 램프 생산시스템 제어에 관한 연구 (A Study for Automotive Lamp Manufacturing System Control Composing Ultra melting Process)

  • 이일권;국창호;김승철;김기진;한기봉
    • 한국가스학회지
    • /
    • 제18권1호
    • /
    • pp.46-51
    • /
    • 2014
  • 이 논문의 목적은 자동차 램프의 초음파 접합 공정을 합성한 자동차 램프 생산시스템에 관한 연구이다. 램프어셈블리를 생산할 때 독립된 단순 공정에 의해 사출과 초음파 접합, 항온풀림, 조립과 포장을 하던 분리된 작업공정을 원스텝(One-step) 일관공정으로 합성하여 초음파 접합시 발생되는 미세한 발생가스와 소음에 대하여 작업자에게 미치는 영향을 최소화하였다. 또한, 합성 공정에 의한 에너지 저감과 이를 자동공정에 의해 생산함으로써 생산 효율을 극대화하였다. 이 방식은 제어시스템의 타당성을 검토하기 위해 수학적 모델링을 하였고, 이들 수식을 이용하여 플랜트의 전달함수와 필요에 따라 bode선도를 이용하여 안정성과 적합한 제어기를 선정하였다. 이 연구에서 사출 물을 뒤집기 위한 $180^{\circ}$ 회전 제어장치는 중력의 영향으로 비선형 항 $M_{eq}\;lcos{\theta}(t)$이 나타났고, 이를 해결하기위해 피드포워드 제어기법을 적용하여 시스템의 선형화 및 안정화를 확보하였다.

PLA/CNT 복합재료의 결정화 특성 및 가수분해에 미치는 CNT 영향에 대한 연구 (A Study on the Effect of CNT on Crystallization Kinetics and Hydrolytic Degradation of PKA/CNT Composite)

  • 이미현;김성하;김시환;박종규;이우일
    • Composites Research
    • /
    • 제24권4호
    • /
    • pp.5-10
    • /
    • 2011
  • 환경오염이 나날이 증가함에 따라 바이오 재료에 대한 관심이 커지고 있다. 본 연구에서는 생분해성 열가소성 수지인 폴리 유산 (PLA)을 기지재료로 하고 탄소나노튜브 (CNT)를 나노 filler로 사용하여 압출 및 사출공정을 통하여 복합재료를 제작하였다. 시편의 결정화도를 변화시키기 위하여 어닐링 시간에 변화를 주어 처리하였다. PLA의 결정화 특성은 시차주사열량계 (DSC)를 통하여 평가하였고, 적당한 양의 CNT가 PLA의 결정화 속도를 향상시킨 것을 확인할 수 있었다. 그 외에 PLA/CNT 복합재료의 가수분해 속도는 순수 PLA에 비하여 빠르지만 PLA/CNT 복합재료의 결정화도가 증가함에 따라 가수분해 속도가 늦어지는 것을 확인할 수 있었다. 이것은 가수분해가 PLA/CNT의 계면에서 쉽게 일어나고 결정화도가 높아짐에 따라 분자 구조가 치밀해지기 때문인 것으로 판단 된다.

저비용 수제 연신레오미터 개발 및 성능 평가 (Development and performance evaluation of a low-cost custom-made extensional rheometer)

  • 김시현;박한별;김정현
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.110-118
    • /
    • 2023
  • Characterizing the extensional rheological properties of non-Newtonian fluids is crucial in many industrial processes, such as inkjet printing, injection molding, and fiber engineering. However, educational institutions and research laboratories with budget constraints have limited access to an expensive commercial extensional rheometer. In this study, we developed a custom-made extensional rheometer using a CO2 laser cutting machine and 3D printer. Furthermore, we utilized a smartphone with a low-cost microscopic lens for achieving a high spatial resolution of images. The aqueous polyethylene-oxide (PEO) solutions and a Boger fluid were prepared to characterize their extensional properties. A transition from a visco-capillary to an elasto-capillary regime was observed clearly through the developed rheometer. The extensional relaxation time and viscosity of the aqueous PEO solutions with a zero-shear viscosity of over 300 mPa·s could be quantified in the elasto-capillary regime. The extensional properties of the solutions with relatively small zero shear viscosity could be calculated using a smartphone's slow-motion feature with increasing temporal resolution of the images.

드럼세탁기용 커플링 부품 다이캐스팅 금형개발 (Development of Mold for Coupling Parts for Drum Washing Machine)

  • 박종남;노승희;이동길
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.482-489
    • /
    • 2020
  • 본 연구의 목적은 소비자 및 현장의 니즈에 부합하면서 다이캐스팅으로 생산할 수 있는 커플링 부품을 개발하고자 하였으며, 유동 및 응고해석을 기반으로 다이캐스팅 금형 설계, 제작, 및 사출조건 최적화 도출을 실시하였고 사출된 제품의 측정 및 평가를 수행하였다. 유동해석을 통하여 캐비티 내부가 100 % 충진되기 위한 적정한 사출조건은 용탕의 온도 670 ℃, 사출속도 1.164 m/s, 충진압력 6.324~18.77 MPa로 분석되었다. 또한, 응고율이 69.47 %일 때 4개의 캐비티 모두에서 100 %에 근접하는 응고가 발생됨을 알 수 있었으며, 이를 기초로 시사출 조건설정 등에 응용하였으며 그 결과 사이클 타임은 약 6.5초로 도출되었다. 다이캐스팅으로 시사출된 제품의 표면 및 내부의 품질 검사를 수행한 결과 성형불량 및 기공 등의 결함은 전혀 발견되지 않았으며, 주요 개소의 치수를 측정한 결과 모든 항목에서 허용하는 공차 이내의 값을 보였다. 또한, 게이트로부터 약 45 mm 이격된 곳의 평균 경도값은 97.7(Hv)로 나타나는 등 전체적으로 양호한 치수 및 품질의 부품을 제작할 수 있었다.

적인 함유량에 따른 LDPE 수지 film의 특성연구 (Characteristics of LDPE resin film depending on RP contents)

  • 조동수;노영태;박병선
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6655-6665
    • /
    • 2015
  • 할로겐계 난연제의 환경적 문제로 인한 규제가 강화되면서 비할로겐타입의 인계화합물을 기초로 한 난연제의 비중이 높아지고 있으며, 기능성 film 제조에 있어 난연 효과를 보이는 적인 첨가에 따라 수지의 물성 및 열적 특성이 확연히 달라진다. 난연 효과를 높이고자 난연제 과량 첨가시 수지의 물성은 크게 저하되며, 수축 또는 방청 등 기능성 film에 적용되기 어렵다. 본 연구에서는 적인MB의 함유량에 따른 LDPE film을 blow 타입의 사출공청을 통해 제조하였고, 이에 대한 난연성 시험과 인열 강도 및 수축률, 방청성 평가를 통해 적인-LDPE film의 기계적 특성 및 물성특성에 미치는 영향력과 함유량에 따른 적인난연 film의 특성연구를 그 목적으로 하였다. 난연성의 경우 VTM 0를 보였으며, 인열 강도의 경우 MD 및 TD의 경향성이 상반되는 것을 알 수 있었다. 수축률의 경우 함유량에 따른 특성은 보이지 않았으며, 방청성의 경우 국내 방청 수축 필름 신뢰성 규격의 기준인 0.05 % 보다 우수한 결과를 보였다.

컴퓨터지원공학(CAE)을 활용한 자동차 부품 개선 (Application of CAE in Injection Molding Process of Automobile Part)

  • 조정환;장우진;박영훈;최순자
    • 공업화학
    • /
    • 제18권5호
    • /
    • pp.407-414
    • /
    • 2007
  • Moldflow사의 CAE 해석 프로그램인 MPI (Moldflow Plastics Insight)를 이용하여 PP(polypropylene)에 talc 20%가 들어간 수지를 사용한 자동차 공기 청정기 상부 덮개의 최적 공정을 찾았다. 핀 게이트가 하나인 기존 시스템을 CASE-1, 두 개로 새로운 공정을 CASE-2로 디자인하여 두 공정에 대한 유동 발란스 등을 비교하였다. CASE-2는 충진 시간이 더 짧아 생산성과 공정성의 향상이, 유동성과 부피수축율이 하부 덮개와 유사하게 나타나 조립성과 조립 후의 변형 및 물성발현이 향상되었다. 또한 전단속도와 전단응력의 해석결과, CASE-1의 문제점은 잔류 응력에 의한 것보다는 상 하부 덮개의 크기 차이에 의한 것으로 판단되며, 결국 수지의 배향 문제는 게이트 구조를 최적화 함으로써 파손 문제를 해결할 수 있을 것이라 예상된다.

다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작 (Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging)

  • 박정찬;오지은;우승태;곽원정;이정은;김경민;안광일;최태현;천기정;장용민;이상우;안병철;이재태;유정수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.401-409
    • /
    • 2008
  • 목적: 최근 들어, 분자 영상에서 다중 영상 기법이 널리 보급되고 있다. 우리는 PET/MR 융합 영상을 얻기 위해 쉽게 이용 가능한 점토와 순간 고형제를 이용하여 동물 특이적 자세 고정 틀을 제작하였다. 동물 특이적 자세 고정 틀은 동물의 고정과 재현성 있는 자세 연출이 가능하도록 한다. 여기에서 우리는 실험 동물의 틀을 제작하는데 있어 점토와 순간 고형제를 비교해 보았다. 재료 및 방법: MicroPET의 받침대와 잘 맞는 바닥이 둥근 아크릴 받침대를 먼저 제작하였다. 실험 동물은 마취 후, 자세 고정을 위해서 틀 위에 올려놓았다. 틀 제작을 위하여 순간 고형제와 점토가 사용되었다. 순간 고형제와 점토를 사용한 두 가지 경우 모두, 실험 동물의 자세 고정을 위하여 부드럽게 실험 동물을 눌러 위치를 잡았다. 위치가 잡혔으면, 쥐를 들어내고, 점토로 뜬 틀은 $60^{\circ}C$ 건조기에 넣어 두어 완전히 경화시켰다. 그리고 $[^{18}F]FDG$용액이 든 밀봉된 4개의 파이펫 팁을 기준 마커로 사용하였다. 실험 동물의 꼬리에 $[^{18}F]FDG$를 정맥 주사하여 microPET 스캔을 실시한 후, 동일한 실험동물을 순차적으로 MRI 스캔하였다. 결과: 다중 영상을 위하여 점토와 순간 고형제로 동물 특이적 자세 고정 틀을 제작하였다. MicroPET과 MRI를 통하여 기능적이고 해부학적인 영상을 얻었다. PET/MR 융합 영상은 무료로 이용 가능한 AMIDE 프로그램을 사용하여 획득할 수 있었다. 결론: 쉽게 이용 가능한 점토, 순간 고형제와 일회용 파이펫 팁을 사용하여 성공적으로 동물 특이적 자세 고정 틀을 제작할 수 있었다. 동물 특이적 자세 고정 틀 덕택으로, 적은 오차 범위 내에서 PET/MR 융합 영상을 얻을 수 있었다.

마이크로 코어 핀 정밀 연삭 시스템 (Precision Grinding System for Micro Core-pin)

  • 양지경;이인철;강동성;한봉석;한유진;이정우;송기혁
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.50-57
    • /
    • 2017
  • 본 사출 금형을 통해 제품 생산 시 사출 금형 내에서 제품 형상을 형성하는 코어는 금형 내부에 틀의 형태로 가공되어 설치되며 이때 부분적인 코어의 형상을 핀에 가공하여 설치하는 부품을 코어 핀이라 한다. 이러한 사출 코어 용 코어 핀은 제품의 소형화 집적화에 따라 그 크기가 마이크로의 크기로 작아지고 있다. 하지만 이를 가공 시 기존의 센터리스 연삭 장치로는 마이크로 사이즈의 피삭재를 고정하여 밀착 시켜주는 장치의 부재로 인해 진동이 발생한다. 이러한 이유로 마이크로 크기의 직경을 가지는 코어 핀의 경우 가공 시 진동에 의해 변형 발생으로 가공 불량률이 매우 높다. 따라서 본 논문에서는 마이크로 크기의 코어 핀을 가공하기 위해 기존의 평면 연삭기에 설치하여 사용이 가능한 소형의 연삭 시스템을 개발 하였다. 이를 이용하여 코어 핀에 대한 연삭 실험을 진행하였으며 표면 거칠기, 진원도, 원통도의 측정을 통해 성능을 검증하였다.