• Title/Summary/Keyword: Co-fire

Search Result 935, Processing Time 0.033 seconds

Application Study of Design Fire Curves for Liquid Pool Fires in a Compartment (구획실 내 액체 풀화재에 대한 디자인 화재곡선 적용 연구)

  • Baek, Bitna;Oh, Chang Bo;Lee, Eui Ju;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.43-51
    • /
    • 2017
  • In this study, new design fire curves were suggested for the utilization in fire simulations. Numerical simulations with the Fire Dynamics Simulator (FDS) were performed for the n-octane and n-heptane pool fires in the ISO 9705 compartment to evaluate the prediction performance of the previous quadratic, exponential design fire curves and newly suggested ones. The numerical results were compared with the experimental temperature and concentrations of $O_2$ and $CO_2$. The numerical results with the previous quadratic and exponential curves showed slow increase and decrease trend than experiments. However, the numerical results with the newly suggested 2 design fire curves showed more similar variation trend in temperature, $O_2$ and $CO_2$ concentrations than the quadratic and exponential curves. It was found that the newly suggested design fire curves can be possibly used in the numerical simulation of fires in a practical respect.

A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring (옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구)

  • Kim, Doo-Hyun;Kim, Eun-Jin;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

Development of an Inert Gas Water Mist System -A Numerical Study on Ventilation of the Fire Test Room- (불활성가스 미분무소화설비의 개발 -화재시험실의 급기에 관한 수치연구-)

  • Park, Woe-Chul;Jeong, Lee-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • A Numerical study was carried out for a propane gas pool fire in the fire test room of $2.5m{\times}2.0m{\times}2.5m$ for testing a inert gas water mist system, to investigate a possible under-ventilation in the fire test room. For the fire sizes of 60 kW and 120 kW, changes in the temperature and CO concentration with and without a window were investigated. It was confirmed that the influence of the window on the distributions of temperature and CO concentration was small in the two fire sizes, and hence the under-ventilation was not occurred in the room.

  • PDF

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.

A Quantitative Analysis on the Extinguishing Mechanism of Laminar Diffusion Flames by $CO_2$ ($CO_2$에 의한 층류 확산화염의 소화기구에 관한 정량적 분석)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Oh, Chang-Bo;Park, Won-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.378-381
    • /
    • 2011
  • 대표적 가스계 소화약제인 $CO_2$의 소화기구(Extinguishing mechanism)를 재조명하기 위하여, $CH_4$/air 저 신장율 대향류 확산화염을 대상으로 $CO_2$가 소화에 미치는 영향에 대한 수치해석이 수행되었다. 부력이 지배적인 화염의 소화현상은 복사 열손실에 의해 큰 영향을 받기 때문에, 소화농도 예측에 대한 복사모델의 성능평가가 우선적으로 이루어졌다. 주요 결과로서, 공기류에 첨가된 $CO_2$의 소화농도는 복사모델이 고려되지 않은 경우 과다 예측되는 반면에, 간략화된 광학적으로 얇은 근사(Optically thin approximation) 모델과 비교적 높은 정확도를 갖는 좁은 밴드(Statistical narrow band) 모델은 실험의 오차범위 내에서 큰 차이를 보이지 않았다. $CO_2$가 소화에 미치는 순수 희석효과, 희석에 의한 복사효과, 화학적 효과 및 열적효과를 정량적으로 분석하기 위하여 가상의 소화약제의 개념을 도입하였다. 이를 통해 화염의 총괄신장율에 따른 $CO_2$ 소화효과에 대한 구체적인 이해가 시도되었다.

  • PDF

Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors (실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구)

  • Choi, Su-Gil;Young, Jin-Se;Park, Sang-Min;Nam, Yeong-Jae;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.37-46
    • /
    • 2020
  • This is a basic research on potential application of fire detection by measuring fire detection tendency of indoor air quality measurement factors. In this study, operation experiment using smoke detector sensitivity tester and paper fire experiment specified in UL 268 standards were conducted to evaluate the fire detection tendency of indoor air quality measurement factors. Based on the cross-substitution of values measured in the paper fire experiment, PM10 (excluding average) and HCHO (excluding average and maximum) for the indoor air quality meter (IAQ); PM1.0, PM2.5, and PM10 for IAQ S2; and CO (excluding the average and maximum) for combustion gas analyzers showed consistent tendency despite changes in the measured values for smoke generation under all experimental conditions. In particular, PM10 and CO are considered the most applicable fire detection factors among the factors measured in the experiment.

Estimation on Greenhouse Gases(GHGs) Emission of Large Forest Fire Area in 2013 (RapidEye 영상을 활용한 대형산불피해지의 온실가스 배출량 추정)

  • Won, Myoung-Soo;Kim, You-Seung;Kim, Kyong-Ha
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.54-67
    • /
    • 2014
  • This study was performed to estimate Greenhouse gases(GHGs) emissions from biomass burning at large forest fire(Ulju, Pohang and Bonghwa) in 2013. The extended methodology to estimate GHGs adopted the IPCC(Intergovermental Panel on Climate Change) Guidelines(2006) equation. For classifying fire damaged area and analyzing burn severity of total three large-fire area damaged, this study used post-fire imagery from Rapideye imagery to compute the Maximum Likelihood Classifiction (MLC). The result of accuracy assessment on burn severity from imagery showed that average overall accuracy was 75.93% and Kapp coefficient was 0.67 Finally, GHGs emissions from biomass burning in the three large-fire area 2013 were estimated as follows: Ulju $CO_2$ 63,260, CO 5.207, $CH_4$ 360, $N_2O$ 28.0 and $NO_x$ $4.4g/kg^{-1}{\cdot}ha^{-1}$, Pohang $CO_2$ 28,675, CO 2.359, $CH_4$ 163, $N_2O$ 12.7 and $NO_x$ $1.9g/kg^{-1}{\cdot}ha^{-1}$ and Bonghwa $CO_2$ 53,086, CO 1,655, $CH_4$ 114, $N_2O$ 23.5 and $NO_x$ $3.6g/kg^{-1}{\cdot}ha^{-1}$.

Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System (가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발)

  • So, Soo-Hyun;Oh, Ju-Hwan;Cha, Cheol-Woong;Lee, Dae-Kuen
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

The Development of Virtual Fire Control System Considering Operational Environment of Helicopter (헬기 운용환경을 고려한 가상 사격 통제 시스템 개발)

  • Kim, Woosik;Lee, Dongho;Jang, Indong;Park, Hanjoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.448-455
    • /
    • 2014
  • Virtual Fire Control System(VFCS) in attack helicopter is developed. VFCS is comprised of multifunction display, store management computer, mission computer, target acquisition and designation system, mission planning system, weapon simulator and flight simulator. Weapon engagement process under the operational environment of helicopter was considered by using the VFCS. We considered hellfire missile, tow missile, unguided rocket and turret gun. The results of this study will be utilized efficiently on integrated fire control system SIL(System Integration Lab.) in attack helicopter.

The development of fire protection trough (밀폐형 방재트러후 개발)

  • Hwang, S.C.;Kim, T.K.;Go, C.S.;Han, K.J.;Kim, D.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1168-1170
    • /
    • 1993
  • EHV underground transmission cable characterized by low loss and bulk capacity should have high reliability to be protected fully from external damages, not to speak of its quality. In 345kV underground transmission lines of our country, the usage of frie protection trough is standardized. Fire protection trough consists of combination of trough body, spacer, shutting board, fastener, and etc. and it is required to have a high level of fire-retardant characteristics and mechanical strength. Since 1992, we, GoldStar Cable, with collaboration of Lucky, have participated in the development of fire protect ion trough and completed the type test of manufacturing site and will be supposed to go into mass product within 1993.

  • PDF