• Title/Summary/Keyword: Closed-type

Search Result 1,267, Processing Time 0.036 seconds

Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System (물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구)

  • Hong, Boo-Pyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

A Study on the Preliminary Classification System for the Development of the Application Model of Closed School Facilities - Focused on the Comparison of Public Design Indicators with Pre-research - (폐교시설의 활용모형 개발을 위한 예비 분류체계 도출 연구 - 선행연구와 공공 디자인지표의 비교를 중심으로 -)

  • Kim, Jae-young;Lee, Jong-kuk
    • Youth Facilities and Environment
    • /
    • v.17 no.1
    • /
    • pp.131-141
    • /
    • 2019
  • The purpose of this study is to derive and type utilization indexes by comparing public design indicators with preceding studies related to closed school facilities, and to derive preliminary classification systems through a correlation review between indicators. Pre-research was conducted in the scope of academic papers, academic journals, research reports, and special act for promoting the utilization of closed school assets. Public design indicators were set in the scope of domestic design guidelines, the Seoul city public design assessment system, the 'Good Building' designation system, and the UK Design Quality Index (DQI). and the design review of the British architects. First of all, the research method looked at laws, procedures and utilization of closed schools, and reviewed the preceding study and domestic and international public design indicators sequentially. Next, the association was reviewed through a comparison between the preceding study and the public design indicators, and a preliminary classification system for the use of closed schools was derived from this.

A Comparative Study on the Status and Utilization Types of Closed Schools in Rural and Islands - Comparative Study of Closed School in Goesan-gun, Chungcheongbuk-do, and Sinan-gun, Jeollanam-do - (농촌지역과 도서지역의 폐교 현황과 활용 유형 비교 연구 - 충청북도 괴산군과 전라남도 신안군 폐교를 중심으로 -)

  • Moon, Seang Hyen
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.1
    • /
    • pp.11-20
    • /
    • 2024
  • Due to the decrease in the school-age population and the overall population, school closures will continue to occur. Currently, most school closures are happening in rural areas, where geographical conditions often result in relatively poor educational, welfare, and cultural facilities compared to urban areas. Additionally, the proportion of elderly populations and migrant women is continuously increasing. In order to effectively utilize closed schools in the future, various efficient utilization methods that align with the social context of the respective regions will be necessary. The purpose of this study is to examine the status of closed school and utilization types in selected rural and island areas of similar sizes through field surveys and literature reviews. By comparing and analyzing these findings, we have identified the predominant utilization types in rural and island areas and assessed the current situation where utilization is lacking. Based on the results, we aim to provide fundamental data for improving and enhancing the utilization of school closures in the face of the ongoing decline in the school-age population.

The clinical usefulness of closed reduction of nasal bone using only a periosteal elevator with a rubber band

  • Park, Young Ji;Ryu, Woo Sang;Kwon, Gyu Hyeon;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.284-288
    • /
    • 2019
  • Background: Closed reduction of nasal fracture with various instrument is performed to treat nasal fracture. Depending on the type of nasal fracture and the situation in which it is being operated, the surgeon will determine the surgical tool. The objective of this study was to investigate whether a periosteal elevator (PE) was a proper device to perform closed reduction for patients with simple nasal fractures. Methods: From March 2018 to December 2018, 50 cases of simple nasal bone fracture underwent closed reduction performed by a single surgeon. These patients were divided into two groups randomly: nasal bone reduction was performed using only PE (freer) and nasal bone reduction was performed using Walsham, Asch forcep, and Boies elevator (non-freer, non-PE). Results: The paranasal sinus computed tomography was performed on patients before and after operation to carry out an accurate measurement of reduction distance at the same level. According to the results, the interaction between instruments and fracture types had a significant influence on reduction distance (p = 0.021). To be specific, reduction distance was significantly (p= 0.004) increased by 2.157 mm when PE was used to treat patients with partial displacement compared to that when non-PEs were used. Conclusion: Closed reduction using PE and other elevator is generally an effective treatment for nasal fracture. In partial-displacement type of simple nasal fracture, closed reduction using PE can have considerable success in comparison with using classic instruments.

Development of a Biped Walking Robot Actuated by a Closed-Chain Mechanism

  • Choi, Hyeung-Sik;Oh, Jung-Min;Baek, Chang-Yul;Chung, Kyung-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.209-214
    • /
    • 2003
  • We developed a new type of human-sized BWR (biped walking robot), named KUBIR1 which is driven by the closed-chain type of actuator. A new type of the closed-chain actuator for the robot is developed, which is composed of the four-bar-link mechanism driven by the ball screw which has high strength and high gear ratio. Each leg of the robot is composed of 6 D.O.F joints. For front walking, three pitch joints and one roll joint at the ankle. In addition to this, one yaw joint for direction change, and another roll joint for balancing the body are attached. Also, the robot has two D.O.F joints of each hand and three D.O.F. for eye motion. There are three actuating motors for stereo cameras for eyes. In all, a 18 degree-of-freedom robot was developed. KUBIR1 was designed to walk autonomously by adapting small 90W DC motors as the robot actuators and batteries and controllers are on-boarded. The whole weight for Kubir1 is over 90Kg, and height is 167Cm. In the paper, the performance test of KUBIR1 will be shown.

  • PDF

Closed loop type MCV(Main Control Valve) for Hydraulic Excavator (유압 굴삭기용 폐루프 타입 MCV(Main Control Valve))

  • Lim T.H.;Lee H.S.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.864-870
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. From the simulation results, fixed spring stiffness of MCV can't satisfy accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing proportional gain is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The simulator can be used to forecastexcavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

Pore Size and its Distribution as a Function of Sintered Density of UO2-20 wt%CeO2Pellets (UO2-20 wt%CeO2소결체의 밀도에 따른 기공크기 및 분포)

  • 나상호;김기홍;김시형;이영우;유명준
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.572-576
    • /
    • 2003
  • Open/closed porosity, pore size and its distribution and pore type as a funtion of sintered density of UO$_2$-20 wt%CeO$_2$ pellets were investigated. Pore appeared almost closed-type with the density above 96% of the theoretical density. Bimodal pore size distribution was observed regardless of the sintered density, but the number of pore decreased with increasing the sintered density. The shape of pore was changed from irregular shape to round type with increasing the sintered density.

Parametric analyses for the design of a closed-loop passive containment cooling system

  • Bang, Jungjin;Hwang, Ji-Hwan;Kim, Han Gon;Jerng, Dong-Wook
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1134-1145
    • /
    • 2021
  • A design parameter study is presented for the closed-loop type passive containment cooling system (PCCS) which is equipped with two heat exchangers: one installed at the inside of the containment and the other submerged in the water pool at the outside of the containment. A GOTHIC code model for PCCS performance analyses was set up and the design parameters such as the heat exchanger sizes, locations, and water pool tank volumes were analyzed to investigate the feasibility of installing this type of PCCS in PWRs like OPR-1000 being operated in Korea. We identified the size of the circulation loop and heat exchangers as major design parameters affecting the performance of PCCS. The analyses showed that the heat exchangers in the inside of the containment would be more influential on the heat removal capability of PCCS than that installed in the water pool at the outside of the containment. Hence, it was recommended to down-size the heat exchangers in the water pool to optimize PCCS without compromising its performance. Based on the parametric study, it was demonstrated that a closed-loop type PCCS could be designed sufficiently compact for installation in the available space within the containment of PWRs like OPR-1000.

Indoor Environment Due to Multi-cultural Complex Space Structure Impact on the Choice of Guests (복합 문화공간 구조에 따른 실내환경이 이용객의 선택에 미치는 영향)

  • Kang, Jin-Young;Won, Young-Suk;Cha, Jung-Hoon;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.4
    • /
    • pp.278-286
    • /
    • 2011
  • Today, people are becoming more conscious regarding environmental-friendliness, and the society as a whole is becoming more aware of it. With such phenomenon, the purpose of this research is to examine how comfort and pleasantness of indoor environment influences when selecting a place for multi-cultural complex. To demonstrate the stated hypothesis, I have preceded the experiment by selecting the C multi-cultural complex of closed-type structure and T multi-cultural complex of open-type structure. The next step I took, in order to validate the public's awareness of environmental-friendliness, was conducting a survey. I then deducted a conclusion through comparison and analysis of experiment measures with survey result. As a result of the research, the experiment measures of each air, light, heat condition of the T multi-cultural complex of open-type structure had a higher measurement for the comfort and pleasantness than the C multi-cultural complex of closed-type structure. Moreover, after validating the consciousness of the public through the survey, they had a tendency preferring T multi-cultural complex of open-type structure over C multi-cultural complex of closed-type structure in terms of comfort and pleasantness. To summarize, it is proper to conclude that the criteria - comfort and pleasantness of indoor environment - has influenced significantly when it comes to selecting a multi-cultural complex through both the experiment and the survey result.

  • PDF

REAL RANK OF $C^*$-ALGEBRAS OF TYPE I

  • Sudo, Takahiro
    • The Pure and Applied Mathematics
    • /
    • v.17 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • We estimate the real rank of a composition series of closed ideals of a $C^*$-algebra such that its subquotients have continuous trace, which is equivalent to that the $C^*$-algebra is of type I.