• Title/Summary/Keyword: Closed-type

Search Result 1,267, Processing Time 0.027 seconds

A Study on the Performance of the Boiling and Condensation Heat Transfer of Vertical Closed Two-Phase Thermosyphons with Low Integral-Fins (관 외벽에 낮은 핀을 가진 수직 열사이폰의 비등 및 응축열전달 성능에 관한 연구)

  • Cho, Dong-Hyun
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 1999
  • An Experimental study on the boiling and condensation heat transfer performance of thermosyphons with low intergral-fins was performed to investigate its heat transfer characteristics. A plain thermo syphon having the same inner and outer diameter as the finned thermosyphons was also tested for comparison. Water and CFC-30 was used as working fluids. The experimental results have been assessed and compared with same existing theories. Good agreement with the theories of Imura and Nusselt was obtained. The vertical closed-type thermosyphons with low integral-fins gave significant increases in the overall heat transfer coefficient compared to plain thermosyphon. In addition, the overall heat transfer coefficients and the operating characteristics was obtained as a function vof operating temperature for the practical applications. Also, the closed two-phase thermosyphons with low integral-fins would be highly recommended to achieve some inexpensive and compact heat exchangers in the range of low temperatures.

  • PDF

OPTION PRICING IN VOLATILITY ASSET MODEL

  • Oh, Jae-Pill
    • Korean Journal of Mathematics
    • /
    • v.16 no.2
    • /
    • pp.233-242
    • /
    • 2008
  • We deal with the closed forms of European option pricing for the general class of volatility asset model and the jump-type volatility asset model by several methods.

  • PDF

Comparative Study for the Efficacy of Small Bore Catheter in the Patients with Iatrogenic Pneumothorax

  • Noh, Tae-Ook;Ryu, Kyoung-Min
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.418-422
    • /
    • 2011
  • Background: It has recently become most general to use the small bore catheter to perform closed thoracostomy in treating iatrogenic pneumothorax. This study was performed for analysis of the efficacy of treatment methods by using small bore catheter such as 7 F (French) central venous catheter, 10 F trocar catheter, 12 F pigtail catheter and for analysis of the appropriateness of each procedure. Materials and Methods: From March 2007 to February 2010, Retrospective review of 105 patients with iatrogenic pneumothorax, who underwent closed thoracostomy by using small bore catheter, was performed. We analyzed the total success rate for all procedures as well as the individual success rate for each procedure, and analyzed the cause of failure, additional treatment method for failure, influential factors of treatment outcome, and complications. Results: The most common causes of iatrogenic pneumothorax were presented as percutaneous needle aspiration(PCNA) in 48 cases (45.7%), and central venous catheterization in 26 cases (24.8%). The mean interval to thoracostomy after the procedure was measured as 5.2 hours (1~34 hours). Total success rate of thoracostomy was 78.1%. The success rate was not significantly difference by tube type, with 7 F central venous catheter as 80%, 10 F trocar catheter as 81.6%, and 12 F pigtail catheter as 71%. Twenty one out of 23 patients that had failed with small bore catheter treatment added large bore conventional thoracostomy, and another 2 patients received surgery. The causes for treatment failure were presented as continuous air leakage in 12 cases (52.2%) and tube malfunction in 7 cases (30%). The causes for failure did not present significant differences by tube type. Statistically significant factors affecting treatment performance were not discovered. Conclusion: Closed thoracostomy with small bore catheter proved to be effective for iatrogenic pneumothorax. The success rate was not difference for each type. However, it is important to select the appropriate catheter by considering the patient status, pneumothorax aspect, and medical personnel in the cardiothoracic surgery department of the relevant hospital.

An Experimental Study on Forming an Axi-Symmetric Dome Type Closed-Die Forging Product Using Modeling Material(I) (모델링재료를 이용한 축대칭형 돔형상의 폐쇄단조 성형 연구 (I))

  • 이근안;임용택;이종수;홍성석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2082-2089
    • /
    • 1992
  • An experimental study on forging an axi-symmetric dome type of AISI4130 was carried out using modeling material. In order to verify the validity of the experimental data, a similarity study between plasticine and AISI4130 has been made. Friction conditions were characterized by ring test for the various lubricants. For the closed-die forging experiments of an axi-symmetric dome type of AISI4130 using the plasticine, various cylindrical billets with different aspect ratios were forged and different flash width to thickness(W/T) ratios were used in order to determine the optimum forging conditions. As W/T ratios decrease forging loads decrease while excess volumes increase. It was found out that the experimental results reproduce the similiar results available in the literature. As a result of these experiments, it was construed physical modeling is an excellent tool for forging process simulation at a practical level.

Olfactory Dysfunction in Nasal Bone Fracture

  • Kim, Sug Won;Park, Beom;Lee, Tae Geun;Kim, Ji Ye
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.92-96
    • /
    • 2017
  • Background: All nasal bone fractures have the potential for worsening of olfactory function. However, few studies have studied the olfactory outcomes following reduction of nasal bone fractures. This study evaluates posttraumatic olfactory dysfunction in patients with nasal bone fracture before and after closed reduction. Methods: A prospective study was conducted for all patients presenting with nasal bone fracture (n=97). Each patient consenting to the study underwent the Korean version of Sniffin' Sticks test (KVSS II) before operation and at 6 month after closed reduction. The nasal fractures were divided according to the nasal bone fracture classification by Haug and Prather (Types I-IV). The olfactory scores were compared across fracture types and between preoperative and postoperative settings. Results: Olfactory dysfunction was frequent after nasal fracture (45/97, 46.4%). Our olfactory assessment using the KVSS II test revealed that fracture reduction was not associated with improvements in the mean test score in Type I or Type II fractures. More specifically, the mean posttraumatic Threshold, discrimination and identification score decreased from 28.8 points prior to operation to 23.1 point at 6 months for Type II fracture with septal fracture. Conclusion: Our study has revealed two alarming trends regarding post-nasal fracture olfactory dysfunction. First, our study demonstrated that almost half (46.4%) of nasal fracture patients experience posttraumatic olfactory dysfunction. Second, closed reduction of these fractures does not lead to improvements olfaction at 6 months, which suggest that olfactory dysfunction is probably due to factors other than the fracture itself. The association should be further explored between injuries that lead to nasal fracture and the mechanism behind posttraumatic olfactory dysfunction.

Performance Evaluation of a Two-Product CONWIP System with Poisson Demand Processes (Poisson 수요과정을 갖는 두 품목 콘윕시스템의 성능평가)

  • Park, Chan-Woo;Kim, Su-Min;Bang, Woo-Hyung;Lee, Hyo-Seong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.3
    • /
    • pp.172-182
    • /
    • 2013
  • In this study we consider a flow line CONWIP system in which two types of product are produced. The processing times of each product type at each station follow an independent exponential distribution and the demands for the finished products of each type arrive according to a Poisson process. The demands that are not satisfied instantaneously are either backordered or lost according to the number of unsatisfied demands that exist at their arrival instants. For this system we develop an approximation method to obtain the performance measures such as steady state probabilities of the number of parts of each product type at each station, mean waiting times of backordered demands and the proportion of backordered demands. For the analysis of the proposed CONWIP system, we model the CONWIP system as a two class closed queueing network with a synchronization station and analyze the closed queueing network using a product-form approximation method for multiple classes developed by Baynat and Dallery. In the approximation method, each subsystem is analyzed using a matrix geometric method. Comparisons with simulation show that the approximation method provides fairly good results for all performance measures.

Computer Topology and Its Applications

  • Han, Sang-Eon
    • Honam Mathematical Journal
    • /
    • v.25 no.1
    • /
    • pp.153-162
    • /
    • 2003
  • Recently, the generalized digital $(k_{0},\;k_{1})$-continuity and its properties are investigated. Furthermore, the k-type digital fundamental group for digital image has been studies with the generalized k-adjacencies. The main goal of this paper is to find some properties of the k-type digital fundamental group of Boxer and to investigate some properties of minimal simple closed k-curves with relation to their embedding into some spaces in ${\mathbb{Z}}^n(2{\leq}n{\leq}3)$.

  • PDF

MATHIEU-TYPE SERIES BUILT BY (p, q)-EXTENDED GAUSSIAN HYPERGEOMETRIC FUNCTION

  • Choi, Junesang;Parmar, Rakesh Kumar;Pogany, Tibor K.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.3
    • /
    • pp.789-797
    • /
    • 2017
  • The main purpose of this paper is to present closed integral form expressions for the Mathieu-type a-series and its associated alternating version whose terms contain a (p, q)-extended Gauss' hypergeometric function. Certain upper bounds for the two series are also given.

HARNACK ESTIMATES FOR NONLINEAR BACKWARD HEAT EQUATIONS WITH POTENTIALS ALONG THE RICCI-BOURGUIGNON FLOW

  • Wang, Jian-Hong
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.2
    • /
    • pp.313-329
    • /
    • 2020
  • In this paper, we derive various differential Harnack estimates for positive solutions to the nonlinear backward heat type equations on closed manifolds coupled with the Ricci-Bourguignon flow, which was done for the Ricci flow by J.-Y. Wu [30]. The proof follows exactly the one given by X.-D. Cao [4] for the linear backward heat type equations coupled with the Ricci flow.