• 제목/요약/키워드: Closed cycle

검색결과 232건 처리시간 0.021초

원자력발전소 온배수를 이용한 해양 온도차발전 사이클 해석 (Cycle Simulation on OTEC System using the Condenser Effluent from Nuclear Power Plant)

  • 김남진;전용한;김종보
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.37-44
    • /
    • 2007
  • For the past few years, the concern for clean energy has been greatly increased. Ocean Thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regeneration cycle, Kalina cycle, open cycle and hybrid cycle. The results show that the regeneration cycle using R125 showed a 0.17 to 1.56% increase in energy efficiency, and simple Rankine cycle can generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $15^{\circ}C$. Also, the cycle efficiency of OTEC power plant using the condenser effluent from nuclear power plant instead of the surface water increased about 2%.

The Concept of Clean Technology

  • Clift, Roland
    • 청정기술
    • /
    • 제1권1호
    • /
    • pp.34-46
    • /
    • 1995
  • Clean Technology goes beyond Clean-UP (or "End of PiPe) Technologies to include Pollution prevention, waste minimisation, and cleaner production. However, the concept of Clean Technology goes deeper than changes in technology, to ways in which human needs can be satisfied sustainably. In other words, Clean Technology, concentrates on delivering a human benefit rather than making a product. Introducing cleaner technology may therefore involve new commercial relationships as well as new technological practices. In some economic sectors, this involves leasing or providing a service rather than selling a product. Life Cycle Assessment (LCA) is an important tool in Clean Technology. LCA involves determining all the resources used and all the wastes and emissions produced in providing the human benefit. Use of LCA ensures that improved environmental performance in one part of the Life Cycle is not achieved merely at the expense of more environmental damage elsewhere. Going beyond LCA, the concepts of Life Cycle Design and "metabolised" use of materials are approaches to obtain maximum benefit from materials as they pass through the human economy. "Closed-loop" use can be a component of clean technology. Looking beyond simple re-use and recycling, a material may pass through a "cascade of uses". typically a series of applications with progressively lower performance specifications. Closed-loop use necessarily involves a change in commercial practice, because the material or product must be recovered after use.

  • PDF

Multi-criteria Comparative Evaluation of Nuclear Energy Deployment Scenarios With Thermal and Fast Reactors

  • Andrianov, A.A.;Andrianova, O.N.;Kuptsov, I.S.;Svetlichny, L.I.;Utianskaya, T.V.
    • 방사성폐기물학회지
    • /
    • 제17권1호
    • /
    • pp.47-58
    • /
    • 2019
  • The paper presents the results of a multi-criteria comparative evaluation of 12 feasible Russian nuclear energy deployment scenarios with thermal and fast reactors in a closed nuclear fuel cycle. The comparative evaluation was performed based on 6 performance indicators and 5 different MCDA methods (Simple Scoring Model, MAVT / MAUT, AHP, TOPSIS, PROMETHEE) in accordance with the recommendations elaborated by the IAEA/INPRO section. It is shown that the use of different MCDA methods to compare the nuclear energy deployment scenarios, despite some differences in the rankings, leads to well-coordinated and similar results. Taking into account the uncertainties in the weights within a multi-attribute model, it was possible to rank the scenarios in the absence of information regarding the relative importance of performance indicators and determine the preference probability for a certain nuclear energy deployment scenario. Based on the results of the uncertainty/sensitivity analysis and additional analysis of alternatives as well as the whole set of graphical and attribute data, it was possible to identify the most promising nuclear energy deployment scenario under the assumptions made.

철도노반재료의 동상 팽창압 특성에 관한 연구 (The Characteristics of Frost Heaving Pressure on the Railroadbed Materials)

  • 신은철;박정준;이창섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.264-270
    • /
    • 2002
  • The frost heaving pressure can be a problem for weakening of the railroadbed material. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable pressure was developed. This pressure is induced as a result of a curved ice-water interface. This study was initiated to investigate the soils frost heaving expansion pressure and physical characteristics resulting from freezing and freezing-thawing cycle process. Weathered granite soils, sandy soil were used in the laboratory freezing test subjected to thermal gradients under closed-systems.

  • PDF

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

액화천연가스 냉열을 이용한 단일팽창과 이단팽창 사이의 비교 연구 (Comparative Study between Single-stage and Two-stage Expansion Using LNG Cold Heat)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.188-192
    • /
    • 2019
  • Comparative studies between single- and two-stage expansion process using LNG cold heat have been performed for a closed Rankine power generation cycle. PRO/II with PROVISION release 10.0 from Schneider Electric Company was used, and the Peng-Robinson equation of state model with Twu's alpha function was selected for the modeling and optimization of the power generation cycle using LNG cold heat. In two-stage power generation cycle, 6.7% more power was obtained compared to that of single-stage power generation cycle through the optimization works.

폐쇄형 해양온도차발전 사이클에 관한 연구 (A Study of Closed OTEC Power Plants)

  • 신상호;정동수;김종보;서태범;천원기;오정무
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.23-33
    • /
    • 1997
  • 본 연구에서는 Rankine 사이클을 이용한 해양 온도차 발전 시스템을 컴퓨터로 모사했고 작동유체를 변화시켜 가면서 그 성능을 비교하였다. 증발기와 응축기는 UA(총괄열전달계수$\times$전열면적)와 LMTD(대수평균온도차) 방법으로 모사하였으며 터빈과 펌프는 등엔트로피 효율로 모사하였다. 작동유체로는 R22, R290, R1270, R134a, R125, R143a, R32, R410A 그리고 암모니아 등을 사용하였다. 모사 결과 OTEC 발전 시스템의 효율은 작동유체에 상관없이 거의 일정한 것으로 드러났다. 한편 증발기 출구에서의 과열도와 응축기 출구에서의 과냉도는 시스템의 성능에 거의 영향을 미치지 않는 것으로 나타났지만 터빈의 효율과 열교환기의 크기는 시스템 성능에 큰 영향을 미치는 것으로 나타났다. 마지막으로 따뜻한 표층수와 차가운 심해수 사이의 온도차가 $20^{\circ}C$이상일 때 실제로 전기를 생산할 수 있다는 사실을 확인했다.

  • PDF

CMOS 기반의 집적 회로 및 시스템을 위한 극저온 측정 환경 구축 (Measurement set-up for CMOS-based integrated circuits and systems at cryogenic temperature)

  • 안현식;최윤석;한정환;남재원;조건희;김주성
    • 전기전자학회논문지
    • /
    • 제28권2호
    • /
    • pp.174-179
    • /
    • 2024
  • 본 논문에서는 극저온 냉동기를 사용하여 양자 컴퓨터 제어 및 read-out을 위한 CMOS 기반의 집적회로 측정 셋업을 제시한다. CMOS 회로는 큐비트 안정성과 잡음 감소를 위해 3~5 K의 극저온에서 작동해야한다. 기존의 극저온 측정 시스템은 액체 헬륨 담금질이며, 이는 소모성 자원을 장기간 사용하기에 비용이 많이 소모된다. 따라서 헬륨 가스를 장기간 사용해도 비용이 들지 않는 폐쇄 사이클 냉동기(Closed Cycle Refrigerator, CCR) 기반의 극저온 측정 시스템에 대해 설명한다. Gifford-Mcmahon(G-M) 방식의 극저온 냉각기를 이용하여 4.7 K에 도달할 수 있는 냉동기를 구축하였다. 이는 가격 경쟁력이 우수한 극저온 냉동기 셋업이 될 것으로 기대된다.

전력 및 담수생산을 위한 해양온도차발전에 대한 연구 (Study on OTEC for the Production of Electric Power and Desalinated Water)

  • 박성식;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.124-130
    • /
    • 2010
  • Ocean Thermal Energy Conversion(OTEC) power plants have been examined as a viable option for supplying clean energy. This paper evaluated the thermodynamic performance of the OTEC Power system for the production of electric power and desalinated water. The results show that newly developed fluids such as R32, R125, R143a, and R410A that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. Overall cycle efficiency of open cycle is the lowest value of 3.01% because about 10% of the gross power is used for pumping out non-condensable gas. Also, the hybrid cycle is an attempt to combine the best features and avoid the worst features of the open and closed cycles. The overall cycle efficiency of hybrid cycle is 3.44% and the amount of desalinated water is 0.0619 kg/s.

울진 원자력발전소 온배수를 이용한 재생식 해양온도차발전에 대한 연구 (A Study on Regenerative OTEC System using the Condenser Effluent of Uljin Nuclear Power Plant)

  • 강윤영;박성식;박윤범;김남진
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.591-597
    • /
    • 2012
  • For the past few years, the concern for clean energy has been greatly increased. Ocean thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this study, we examined the thermodynamic performance of the OTEC power system for the production of electric power. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regenerative cycle, Kalina cycle, open cycle, and hybrid cycle. The results show that the regenerative cycle showed the best system efficiency. And then we examined the thermodynamic performance of regenerative cycle OTEC power system using the condenser effluent from Uljin nuclear power plant instead of the surface water. The highest system efficiency of the condition was 4.55% and the highest net power was 181 MW.