• Title/Summary/Keyword: Closed circuit

Search Result 341, Processing Time 0.027 seconds

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Estimation of Incident Detection Time on Expressways Based on Market Penetration Rate of Connected Vehicles (커넥티드 차량 보급률 기반 고속도로 돌발상황 검지시간 추정)

  • Sanggi Nam;Younshik Chung;Hoekyoung Kim;Wonggil Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.3
    • /
    • pp.38-50
    • /
    • 2023
  • Recent advances in artificial intelligence (AI) technology have enabled the integration of AI technology into image sensors, such as Closed-Circuit Television (CCTV), to detect specific traffic incidents. However, most incident detection methods have been carried out using fixed equipment. Therefore, there have been limitations to incident detection for all roadways. Nevertheless, the development of mobile image collection and analysis technology, such as image sensors and edge-computing, is spreading. The purpose of this study is to estimate the reducing effect of the incident detection time according to the introduction level of mobile image collection and analysis equipment (or connected vehicles). To carry out this purpose, we utilized data on the number of incidents collected by the Suwon branch of the Gyeongbu expressway in 2021. The analysis results showed that if the market penetration rate (MPR) of connected vehicles is 4% or higher for two-lane expressway and 3% or higher for three-lane expressways, the incident detection time was less than one minute. Furthermore, if the MPR is 0.4% or higher for two-lane expressways and 0.2% or higher for three-lane expressways, the incident detection time decreased compared to the average incident detection time announced by the Korea Expressway Corporation for both two-lane and three-lane expressways.

Computer vision-based remote displacement monitoring system for in-situ bridge bearings robust to large displacement induced by temperature change

  • Kim, Byunghyun;Lee, Junhwa;Sim, Sung-Han;Cho, Soojin;Park, Byung Ho
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.521-535
    • /
    • 2022
  • Efficient management of deteriorating civil infrastructure is one of the most important research topics in many developed countries. In particular, the remote displacement measurement of bridges using linear variable differential transformers, global positioning systems, laser Doppler vibrometers, and computer vision technologies has been attempted extensively. This paper proposes a remote displacement measurement system using closed-circuit televisions (CCTVs) and a computer-vision-based method for in-situ bridge bearings having relatively large displacement due to temperature change in long term. The hardware of the system is composed of a reference target for displacement measurement, a CCTV to capture target images, a gateway to transmit images via a mobile network, and a central server to store and process transmitted images. The usage of CCTV capable of night vision capture and wireless data communication enable long-term 24-hour monitoring on wide range of bridge area. The computer vision algorithm to estimate displacement from the images involves image preprocessing for enhancing the circular features of the target, circular Hough transformation for detecting circles on the target in the whole field-of-view (FOV), and homography transformation for converting the movement of the target in the images into an actual expansion displacement. The simple target design and robust circle detection algorithm help to measure displacement using target images where the targets are far apart from each other. The proposed system is installed at the Tancheon Overpass located in Seoul, and field experiments are performed to evaluate the accuracy of circle detection and displacement measurements. The circle detection accuracy is evaluated using 28,542 images captured from 71 CCTVs installed at the testbed, and only 48 images (0.168%) fail to detect the circles on the target because of subpar imaging conditions. The accuracy of displacement measurement is evaluated using images captured for 17 days from three CCTVs; the average and root-mean-square errors are 0.10 and 0.131 mm, respectively, compared with a similar displacement measurement. The long-term operation of the system, as evaluated using 8-month data, shows high accuracy and stability of the proposed system.

Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter (ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계)

  • 이득기;윤길문;차영길;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.231-239
    • /
    • 1998
  • This paper presents the dynamic analysis and control loop design of a zero voltage switching full bridge (ZVS-FB) PWM DC/DC converter. The small-signal model is derived incorporating the effects of phase shift control and the utilization of transformer leakage inductance and power FET junction capacitance to achieve zero voltage resonant switching. These effects are modeled by introducing additional feedforward and feedback terms for duty cycle modulation. Based on the results of the small-signal analysis, the control loop is designed using a simple two-pole one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system is carried out and the potential of the zero voltage switching and the superiority of the dynamic characteristics are verified through the experiment with a 2 kW prototype converter.

  • PDF

Design of Moving Magnet Type Optical Pickup Actuator with High Frequencies of the Flexible Modes (높은 유연 모드 주파수를 갖는 가동 자석형 광 픽업 액추에이터 개발)

  • Song, Myeong-Gyu;Kim, Yoon-Ki;Park, Young-Pil;Yoo, Jeong-Hoon;Park, No-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1043-1049
    • /
    • 2007
  • Data transfer rate and storage capacity are main criteria of the performance of the optical disk drive. The highest data transfer rate and the largest storage capacity is most desirable. To increase these performances, the actuator of the optical disk drive should have a high servo bandwidth to compensate the vibration of an optical disk. The servo bandwidth is limited by some flexible modes of the actuator, thus it is essential to increase the natural frequencies of the flexible modes. In this paper, we suggested a moving magnet type actuator having high frequencies of the flexible modes. Generally, the moving magnet type actuator has an advantage to increase the natural frequencies of the flexible modes because the moving magnet type actuator has simple structure and the Young's modulus of magnet is high. However, large moving mass and inefficiency of EM(electromagnetic) circuit cut down driving sensitivities of the actuator. To improve driving sensitivities, we designed the model with the closed electromagnetic circuit for tracking direction. In addition, driving sensitivities and the natural frequencies of the flexible modes were improved by using DOE(design of experiments) for electromagnetic circuit and modifying the lens holder.

Study on Equivalent Circuit and Bandwidth of Short Wavelength Thin-film Transmission Line Employing ML/CPW composite structure for Miniaturization of wireless Communication System on RFIC (실리콘 RFIC 상에서 무선 통신 시스템의 소형화를 위한 마이크로스트립/코프레너 복합구조를 가지는 박막필름 전송선로의 등가회로 및 대역폭에 관한 연구)

  • Son, Ki-Jun;Jeong, Jang-Hyeon;Kim, Dong-Il;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • In this paper, we study the RF characteristics of the short wavelength thin-film transmission line employing microstrip line (ML)/coplanar waveguide (CPW) composite structure on silicon substrate for application to RFIC (radio frequency integrated circuit). The thin-film transmission line employing ML/CPW composite structure showed a wavelength shorter than conventional transmission lines. Concretely, at 10 GHz, the wavelength of the transmission line employing ML/CPW composite structure was 6.26 mm, which was 60.5 % of the conventional coplanar waveguide. We also extracted the bandwidth characteristic of the transmission line employing ML/CPW composite structure using equivalent circuit analysis. The S parameter of the equivalent circuit showed a good agreement with measured result. According to the bandwidth extraction result, the cut-off frequency of thin-film transmission line employing ML/CPW composite structure was 377 GHz. Above results indicate that the transmission line employing ML/CPW composite structure can be effectively used for application to broadband and compact RFIC.

Fiber Optic Interferometer Simulator (광섬유 간섭계 시뮬레이터)

  • Yang, Mun-Sang;Chong, Kyoung-Ho;Do, Jae-Chul;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.411-414
    • /
    • 2008
  • The study is about simulation of optical circuit for oneself performance evaluation of Fiber Optic Gyro(FOG) closed-loop controller board. The Fiber Optic Interferometer Simulator is used a digital signal processing for cosine response specificity output of fiber optic coil about input rate. Response specificity of the fiber optic coil is $Vo(t)=K3[1+\cos\{K1(Vm(t)-Vm(t-{\tau}))+K2\}]$. Also the Fiber Optic Interferometer Simulator is able to confirm a output value with K1, K2 and K3 input. The fiber Optic Interferometer Simulator is able to oneself performance evaluation without fiber optical circuit. Because, it is the very same cosine response specificity of real fiber optic coil about input rate.

  • PDF

The Isoflurane Concentration of Precision Vaporizer Goldman Vaporizer According to Room Temperature and Carrier Gas Flow Rate (온도 및 유량에 따른 흡입 마취제 전용 기화기와 Goldman 기화기의 isoflurane 농도 변화)

  • 김성미;장화석;이정선;최치봉;임희란;최준철;김휘율
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.270-275
    • /
    • 2004
  • Anesthetic machines may be equipped with either a precision or nonprecision vaporizer. A precision vaporizer is designed to deliver an exact concentration of anesthetic agent. Goldman vaporizer is a low-flow, closed-circle circuit with a low resistance vaporizer, in circuit. Vaporizers used within circle system(VIC) are not usually temperature compensated and this is generally thought to be a disadvantage. As the volatile agent is vaporized, heat is extracted from the liquid and temperature decreases. This cooling of the liquid leads to a decrease in concentration of the anaesthetic agent delivered by the vaporizer. The purpose of this study is to examine the mechanical consistency of the delivery of isoflurane from Goldman vaporizer and precision vaporizer at various gas flow rates and temperatures. And we first studied isoflurane concentration according to room temperature changes delivered by a Goldman vaporizer and precision vaporizer using different gas flow. The room temperature of $15^{\circ}C,$ $20^{\circ}C,$ $28^{\circ}C$ and fresh gas flow rates of 0.5, 1.0, 1.5, 2.0, 3.0 l/min were used. The inspired agent concentration was measured using a Datex-Ohmeda multigas analyzer. As rose in room temperature, the isoflurane concentration of precision vaporizer approximated the dial setting. On the other hand, at a dial setting concentration of 5.0 percent the delivered isoflurane concentration of precision vaporizer was more than the dial setting in high temperature. The isoflurane concentration of precision vaporizer remained constant despite the increase in temperature. The isoflurane concentration of Goldman vaporizer was increased with rise in room temperature and decreased with rise in gas flow.

An Analysis of Conception Types of High School Students, Chemistry Teachers, and Pre-service Science Teachers about Salt Bridge of Daniel Electronic Cell (다니엘 전지를 구성하는 염다리의 역할에 대한 고등학생, 화학교사, 그리고 예비 과학 교사들의 개념 유형 분석)

  • Park, Jin-Hee;Kim, Dong-Uk;Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.3
    • /
    • pp.544-555
    • /
    • 2004
  • This study examined the conception types of high school students, chemistry teachers, and pre-service teachers about the salt bridge in Daniel cell by a questionnaire and follow-up interviews. High school chemistry II textbooks were analyzed for finding the cause of the understanding difficulties of the teachers and students. Pre-service teachers' thoughts examined for the problems of pre-service teacher programs. From the analysis, it was found that teachers only thought that the role of salt bridge is for ion movement of two solutions involving electrodes. But they didn't have the conception that salt bridge has a roll of connection a circuit. This result was similar to students' and pre-service teachers' results. It was possible that insufficient and different explanations of the textbooks were attributed the teachers' and students' conceptual difficulties.

A Coupled Analysis of Smart Plate Under Electro-Mechanical Loading Using Enhanced Lower-Order Shear Deformation Theory (개선된 저차 전단 변형 이론을 이용한 전기, 기계 하중을 받는 스마트 복합재 구조물의 연성 해석)

  • Oh, Jin-Ho;Cho, Maeng-Hyo;Kim, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.121-128
    • /
    • 2007
  • Enhanced lower order shear deformation theory is developed in this study. Generally, lower order theories are not adequate to predict accurate deformation and stress distribution through the thickness of laminated plate. For the accurate prediction of detailed stress and deformation distributions through the thickness, higher order zigzag theories have been proposed. However, in most cases, simplified zigzag higher order theory requires $C_1$, shape functions in finite element implementation. In commercial FE softwares, $C_1$, shape functions are not so common in plate and shell analysis. Thus zigzag theories are useful for the highly accurate prediction of thick composite behaviors but they are not practical in the sense that they cannot be used conveniently in the commercial package. In practice, iso-parametric $C_0$ plate model is the standard model for the analysis and design of composite laminated plates and shells. Thus in the present study, an enhanced lower order shear deformation theory is developed. The proposed theory requires only $C_0$ shape function in FE implementation. The least-squared energy error between the lower order theory and higher order theory is minimized. An enhanced lower order shear deformation theory(ELSDT) in this paper is proposed for smart structure under complex loadings. The ELSDT is constructed by the strain energy transformation and fully coupled mechanical, electric loading cases are studied. In order to obtain accurate prediction, zigzag in-plane displacement and transverse normal deformation are considered in the deformation Held. In the electric behavior, open-circuit condition as well as closed-circuit condition is considered. Through the numerous examples, the accuracy and robustness of present theory are demonstrated.