• 제목/요약/키워드: Closed Cell

검색결과 276건 처리시간 0.026초

Microbiological Stability Test of Biodisel (바이오디젤의 미생물 안정성 조사)

  • 박근형;정해영;채희정
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제4권4호
    • /
    • pp.387-390
    • /
    • 2003
  • The microbiological stability was examined by detecting the growth of microorganisms in the closed bottles under anaerobic long-term storage at $25^{\circ}C$ and 35$^{\circ}C$. Microbial growth was examined by a microscope and total cell number on a plate medium was quantitatively measured. There was no observed microbial growth in biodiesel for 90 days.

  • PDF

Primary pulmonary adenocarcinoma metastasized to kidney in a captive nutria (Myocastor coypus)

  • Oh, Yeonsu;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • 제40권2호
    • /
    • pp.139-142
    • /
    • 2017
  • A six-year-old male captive nutria (Myocastor coypus) maintained in a closed space with a small vent was found dead in his cage. Gross findings showed multifocal nodules in varying sizes, small 0.5 to large 5 cm in diameter, intermixed with normal parenchyma were scattered all over the surface of the lungs and a kidney, which the cut surface was smooth, compact and whitish in color. Microscopically, small round to oval neoplastic cells with modest to slight amounts of cytoplasm formed acinar and gland-like structures. Immunohistochemically, cells were strongly positive for E-cadherin and slightly reactive for thyroid transcription factor-1 (TTF-1). Based on those diagnostic features, the neoplasia was diagnosed as primary pulmonary adenocarcinoma (small cell type) and metastasized into the kidney. This is the first case report of malignant pulmonary tumor and its metastasis in the nutria.

A hollow definitive obturator fabrication technique for management of partial maxillectomy

  • Patil, Pravinkumar Gajanan;Patil, Smita Pravinkumar
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.248-253
    • /
    • 2012
  • Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

AUTOMATIC TUNING OF FUZZY OPTIMAL CONTROL SYSTEM

  • Hoon-Kang;Lee, Hong-Gi-;Kim, Yong-Ho-;Jeon, Hong-Tae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1195-1198
    • /
    • 1993
  • We investigate a systematic design procedure of automated rule generation of fuzzy logic based controller for uncertain dynamic systems such as an engine dynamic model.“Automated Tuning”means autonomous clustering or collection of such meaningful transitional relations in the state-space. Optimal control strategies are included in the design procedures, such as minimum squared error, minimum time, minimum energy or combined performance criteria. Fuzzy feedback control systems designed by the cell-state transition method have the properties of closed-loop stability, robustness under parameter variabtions, and a certain degree of optimality. Most of all, the main advantage of the proposed approach is that reliability can be potentially increased even if a large grain of uncertainty is involved within the control system under consideration. A numerical example is shown in which we apply our strategic fuzzy controller design to a highly nonlinear model of engine idle speed contr l.

  • PDF

Approximation Method for QoS Analysis of Wireless Cellular Networks with Impatient Calls

  • Eom, Hee-Yeol;Kim, Che-Soong;Melikov, Agassi;Fattakhova, Mehriban
    • Industrial Engineering and Management Systems
    • /
    • 제9권4호
    • /
    • pp.339-347
    • /
    • 2010
  • Simple-closed expressions for approximate calculation of quality of service (QoS) metrics of isolated cell of wireless networks with either finite or infinite queues of both new and handover calls are developed. It is assumed that both kinds of calls might leave the system without receiving service if their waiting times exceed some threshold value. For the models with infinite queues of heterogeneous calls easily checkable ergodicity conditions are proposed. The high accuracy of the developed approximation formulas is shown. Results of numerical experiments are given.

Microwave-assisted extraction of paclitaxel from plant cell cultures (Microwave를 이용한 식물세포배양으로부터 paclitaxel 추출)

  • Hyun, Jung-Eun;Kim, Jin-Hyun
    • KSBB Journal
    • /
    • 제23권4호
    • /
    • pp.281-284
    • /
    • 2008
  • A simple and efficient microwave-assisted extraction procedure was developed and optimized for the extraction of paclitaxel from the plant cell cultures of Taxus chinensis. The biomass, immersed in a methanol-water mixture, was irradiated with microwaves in a closed-vessel system. The microwave-assisted extraction was compared with the existing conventional solvent extraction in terms of yield, extraction time, and solvent consumption. The use of microwave energy allows rapid recovery of paclitaxel from biomass and dramatically reduces extraction time and solvent usage compared to conventional solvent extraction. The paclitaxel was completely extracted from biomass by microwave-assisted extraction for 3 min at $50^{\circ}C$, for 6 min at $30^{\circ}C$ and $40^{\circ}C$, respectively.

CLINICOPATHOLOGIC STUDY OF PLEOMORPHIC ADENOMA IN MINOR SALIVARY GLANDS (소타액선에 발생한 다형성선종의 임상 및 병리학적 고찰)

  • Baik, Seok-Kee;Cha, In-Ho;Kim, Jin;Lee, Eui-Wung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권2호
    • /
    • pp.116-122
    • /
    • 2003
  • Pleomorphic adenoma is the most common salivary neoplasm mainly occurring in the major salivary glands - especially in parotid gland, which is characterized by variable histopathologic appearances and high recurrence rate with malignant transformation according to surgical situations. And this benign mixed tumor occurring in minor salivary glands is believed to shows same clinicopathologic appearances and relatively low recurrent rate compared with the case in major salivary glands. But there are few comparative studies of large series of pleomorphic adenoma occurring in minor salivary glands which includes different histopathologic appearance, clinical characteristics, treatment methods, recurrence rate, and malignant transformation. We retrospectively studied the 54 patients who were pathologically confirmed with pleomorphic adenoma occurring in minor salivary glands, and analyzed the clinico-histopathological appearance, surgical methods, recurrent cases. The results obtained are as follows. 1. The incidence of the tumor was most frequent in 4th & 5th decade, and in female. 2. Palate(90%) including hard & soft palate was the most frequent site for pleomorphic adenoma in minor salivary glands. 3. The exact duration could not be known due to asymptomatic slow growth patterns of the tumor. 4. The mean tumor size was 2.3cm. 5. 28 (52%) pleomorphic adenomas were classified as Cellular type (cell-rich), 17 (31%) specimen as Intermediate type(equal cell to stroma ratio), and 9 (17%) as Myxoid type(stroma-rich). 6. Surgically 51 cases (94%) were showed well-encapsulated tumors, but histopathologically only 34 specimen (63%) were wellencapsulated. Therefore pleomorphic adenomas in minor salivary glands also have to be excised more widely, not enucleated. And in case of suspicious malignancy or large tumor, preoperative incisional biopsy can be applied in the center of the tumor for prevention of rupture of tumor cell, and total excision with use of frozen biopsy for detection of malignancy and confirming the excision margin, and closed follow-up according to final histopathologic results is recommended.

An Analysis of Conception Types of High School Students, Chemistry Teachers, and Pre-service Science Teachers about Salt Bridge of Daniel Electronic Cell (다니엘 전지를 구성하는 염다리의 역할에 대한 고등학생, 화학교사, 그리고 예비 과학 교사들의 개념 유형 분석)

  • Park, Jin-Hee;Kim, Dong-Uk;Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • 제24권3호
    • /
    • pp.544-555
    • /
    • 2004
  • This study examined the conception types of high school students, chemistry teachers, and pre-service teachers about the salt bridge in Daniel cell by a questionnaire and follow-up interviews. High school chemistry II textbooks were analyzed for finding the cause of the understanding difficulties of the teachers and students. Pre-service teachers' thoughts examined for the problems of pre-service teacher programs. From the analysis, it was found that teachers only thought that the role of salt bridge is for ion movement of two solutions involving electrodes. But they didn't have the conception that salt bridge has a roll of connection a circuit. This result was similar to students' and pre-service teachers' results. It was possible that insufficient and different explanations of the textbooks were attributed the teachers' and students' conceptual difficulties.

Radioautographical observations of development and appearance of glia cells in brain I. Apperarace of ectodermal glial cell aggregates in rodent brain (뇌신경교세포(腦神經膠細胞) 집단(集團)의 발생(發生)과 이동(移動)에 대한 방사선(放射線) 자기법적(自記法的) 관찰 I, 설치류 뇌(腦)에 외배엽성(外胚葉性) 신경교세포(神經膠細胞) 집단(集團)의 출현(出現)에 대하여)

  • Kwak, Soo-dong
    • Korean Journal of Veterinary Research
    • /
    • 제32권4호
    • /
    • pp.481-487
    • /
    • 1992
  • The present study was designed to investigate the appearance of the congenital aggregates of the ectodermal glial cells in the brain of the normal rodents. The brain samples were taken from mice fetus, juvenile mice, rats and rabbits. The appearance regions of the glial cell aggregates (GCA) were investigated and the cells in the GCA were identified with electron microscope. 1. GCA in the mouse fetus tended to be higher in cell density, larger in size and lower frequency in appearance than juvenile mouse. The regions of higher appearance frequency of GCA in the juveniles of mice, rats and rabbits were ordered as subependymal layer in the collateral trigone of lateral ventricles, molecular layer of the neocortex, inner layer except the molecular layer in the neocortex, cerebral medulla, corpus callosum and hippocampus. Appearance frequency of GCA in the neonatal mice tended to be higher until 5 day after birth, and were markedly decreased on 10 and 15 day after birth. 2. GCA tended to be closed on one side of the blood vessels or neurons but not perivascular or perineuronal appearance. 3. In electron microscophy, GCA were composed of immature oligodendrocytes and astrocytes in the subependymal, and tended to be more mature and loose in the neocortex and to be appended some microglia cells with age. The cells in the GCA of older mice tended to be more mature than in young mice.

  • PDF

A Study on the Development of Noncontact Soldering Device of PV Cells Using Infrared Lamp (적외선 램프를 이용한 비접촉식 태양전지셀 솔더링 장치 개발에 관한 연구)

  • Lho, Tae-Jung;Kim, Seon-Jin;Park, Min-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권1호
    • /
    • pp.45-50
    • /
    • 2013
  • The reflector of infrared lamp is designed to the optimal circular shape through the analyses of lumination distributions with a triangular, rectangular and circular configurations of infrared lamps respectively by using Photopia. PLC is used to compare and amplify the difference between soldering temperature profile and feedback value. It is fed to IR lamp controller which adjusts the soldering temperature of PV cell. The soldering temperature measured using an infrared temperature sensor is then fed back to the PLC. The closed control loop of soldering temperature on a PV cell is implemented. The noncontact soldering device of PV cells using infrared lamp which is easily operated by HMI operation panel and controlled robustly by PLC and IR lamp controller is developed.