• 제목/요약/키워드: Close-loop control

검색결과 77건 처리시간 0.018초

Fatigue Properties of Copper Foil and the Evolution of Surface Roughness

  • Oh, Chung-Seog;Bae, Jong-Sung;Lee, Hak-Joo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.57-62
    • /
    • 2008
  • The aim of this investigation was to extract the fatigue properties at the designated fatigue life of copper foil and observe the mean stress and stress amplitude effects on both the fatigue life and the corresponding surface morphology. Tensile tests were performed to determine the baseline monotonic material properties of the proportional limit and ultimate tensile strength. Constant amplitude fatigue tests were carried out using a feedback-controlled fatigue testing machine. The mean stress and the stress amplitude were changed to obtain the complete nominal stress-life curves. An atomic force microscope was utilized to observe the relationship between the fatigue damage and the corresponding changes in surface morphology. A Basquin's exponent of-0.071 was obtained through the fatigue tests. An endurance limit of 122 MPa was inferred from a Haigh diagram. The specimen surface became rougher as the number of fatigue cycles increased, and there was a close relationship between the fatigue damage and the surface roughness evolution.

자동차 점화코일의 부분방전특성 (Partial Discharge of Ignition Coil for Automotive)

  • 신종열;김탁용;변두균;김원종;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.239-242
    • /
    • 2003
  • 자동차 점화장치는 전원으로부터 공급된 낮은 전압을 점화코일을 통하여 연소실의 혼합기를 연소시키기에 충분한 고전압을 발생시키는 장치이며, 점화장치의 핵심은 점화코일이다. 이 점화코일은 절연성능이 우수한 절연재료가 사용되지만 고전압의 발생으로 점화코일 내부에서 일어나는 전기적 열화로 인해 누설전류가 흐르게 되어 전기적 고장을 초래할 수 있다. 이로 인하여 절연재료의 수명은 단축되며, 또한 점화코일에 전류가 흐름으로써 코일 내부에서 발생하는 온도변화에 따른 절연열화로 점화코일의 성능이 저하될 수 있다. 따라서 본 연구에서는 점화코일에 사용되고 있는 절연재료에 전압이 인가될 때 발생할 수 있는 비파괴검사의 일종인 부분방전 측정을 통하여 전압변화에 따른 에폭시 성형 점화코일의 위상각($\Phi$) - 방전전하량(q) - 발생빈도수(n)의 특성 변화를 조사하고 분석함으로써 점화코일의 수명을 예측하여 자동차 점화장치의 성능진단과 정보제공을 자동차 전기장치의 발전에 도움이 될 것을 기대하며, 온도상승에 따른 점화코일의 부분방전 특성을 실험하고 분석하였다.

  • PDF

가스보일러 일산화탄소 제어에 관한 연구 (A Study on the Control of the Exhaust CO from Gas Boiler)

  • 조영도;최경석;김지윤;깅창연
    • 한국가스학회지
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 2001
  • 가정집 가스보일러 배기가스 조성에 대하여 열역학적 관점에서 해석하였고 일산화탄소 센서의 특성에 대하여 고찰하였다. 배기가스의 조성 측정으로부터 보일러 연소조건을 예측할 수 있음을 본 연구에서 제시하였다. 즉 배기가스중의 산소농도로부터 과잉 공기량을 예측할 수 있고, 배기가스중의 일산화탄소와 수소의 비율로부터 보일러 연소실 온도를 알 수 있다. 가정집에 설치되어 있는 보일러의 배기가스 조성 해석으로부터 과잉 공기량이 약 $55\~110\%$임을 알 수 있었다. 따라서 가정집 가스보일러에서 발생하는 일산화탄소는 연소가스의 유속구배에 의한 난류에 의한 국부냉각 또는 벽에 의한 국부냉각으로 등에 의하여 발생하는 것으로 사료된다. CO센서의 출력전압은 수소와 일산화탄소의 농도에 선형적으로 비례하며, 보일러에서 일산화탄소 발생을 CO센서와 연동제어로 감소시킬 수 있다.

  • PDF

PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현 (Implementation of the BLDC Motor Drive System using PFC converter and DTC)

  • 양오
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.62-70
    • /
    • 2007
  • 본 논문에서는 일정 토크영역에서 승압형 PFC 컨버터와 직접토크제어(DTC) 방법을 사용하여 BLDC 모터의 구동 시스템을 DSP(TMS320F2812)로 구현하였다. 기존의 6단계 PWM 전류제어와 달리 미리 정한 샘플시간 마다 간단한 look-up 표로부터 2상 도통 모드에 대한 인버터의 전압 상태 벡터를 설정함으로써 원하는 전류파형을 만들었으며 이로부터 기존의 전류제어기보다 훨씬 빠른 토크 응답특성을 얻을 수 있었다. 또한 BLDC 모터의 비 이상적인 사다리형 역기전력에 의해 발생되는 저주파 토크변동을 저감하기 위하여 위치 loop-up 표를 사용하였다. 아울러 역률을 보정하기 위해 승압형 PFC 컨버터를 구성하였고 이 때 전파 정류된 입력전압과 출력전압, 인덕터의 전류에 의해 평균전류모드 제어 방식으로 80 kHz마다 PWM 듀티(duty)가 조절 되도록 하였다. 이와 같이 복잡한 제어 알고리즘은 초고속 DSP의 출현으로 PFC와 DTC 알고리즘이 동시에 제어가 가능하며, 본 논문에서는 DTC 알고리즘을 구현할 때 DSP의 일반 범용의 출력포트를 사용하여 구현하였고 단지 PFC에서만 1개의 PWM을 사용하여 디지털 제어기를 구현하였다. 실험을 통해 DTC 알고리즘과 PFC 컨버터를 이용한 BLDC 모터 구동 시스템의 타당성과 효용성을 보였고, 실험결과로부터 PFC 컨버터를 사용하지 않았을 때는 역률이 약 0.77이었으나 PFC 컨버터를 사용하였을 때는 부하변동에 관계없이 약 0.9997로 크게 향상됨을 확인하였다.

Fresh Produce Container Operated with a Routine of Hypobaric Application, CO2 Injection and Diffusion Tube Opening for Keeping Beneficial Modified Atmosphere

  • Park, Su Yeon;An, Duck Soon;Lee, Dong Sun
    • 한국포장학회지
    • /
    • 제26권2호
    • /
    • pp.53-60
    • /
    • 2020
  • A concept of household container to create and keep the modified atmosphere (MA) beneficial for fresh produce mix was devised and tested under typical chilled storage conditions of 3℃. The container system containing mixed products is initialized by applying weak hypobaric condition (0.9 atm) and subsequently injecting CO2 gas at an appropriate low level (0.03 atm). The passive atmosphere modification by produce respiration is then induced to reach a target until gas diffusion tube of proper dimension starts to open. The design was made to attain quasi-steady state mass balance of O2, CO2 and N2 to maintain the desired MA through the storage. Interrupted opening for taking out or placing some products was to reinitialize the loop of control logic. The developed concept was tested by the container which held commodities of spinach, pak choi, oyster mushroom, peeled onion, strawberry and cut carrot. The target optimum MA of 11% O2 and 10% CO2 (0.11 and 0.10 atm, respectively) was set to avoid injurious range of O2 and CO2 concentrations for any commodities. The developed container system could work to reach and maintain beneficial MA of 0.10-0.12 atm O2 and 0.07-0.10 atm CO2 close to the target during the storage contributing to quality retention of products measured in weight loss, chlorophyll content of spinach, ascorbic acid content of pak choi, color of onion, texture of oyster mushroom, bacterial count of strawberry and carotenoids of carrot. The container system shows potential to improve current preservation practice of fresh produce mix on consumers' level.

SBAS SIGNAL SYNCHRONIZATION

  • Kim, Gang-Ho;Kim, Do-Yoon;Lee, Taik-Jin;Kee, Changdon
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.309-314
    • /
    • 2006
  • In general DGPS system, the correction message is transferred to users by wireless modem. To cover wide area, many DGPS station should be needed. And DGPS users must have a wireless modem that is not necessary in standalone GPS. But SBAS users don't need a wireless modem to receive DGPS corrections because SBAS correction message is transmitted from the GEO satellite by L1 frequency band. SBAS signal is generated in the GUS(Geo Uplink Subsystem) and uplink to the GEO satellite. This uplink transmission process causes two problems that are not existed in GPS. The one is a time delay in the uplink signal. The other is an ionospheric problem on uplink signal, code delay and carrier phase advance. These two problems cause ranging error to user. Another critical ranging error factor is clock synchronization. SBAS reference clock must be synchronized with GPS clock for an accurate ranging service. The time delay can be removed by close loop control. We propose uplink ionospheric error correcting algorithm for C/A code and carrier. As a result, the ranging accuracy increased high. To synchronize SBAS reference clock with GPS clock, I reviewed synchronization algorithm. And I modified it because the algorithm didn't consider doppler that caused by satellites' dynamics. SBAS reference clock synchronized with GPS clock in high accuracy by modified algorithm. We think that this paper will contribute to basic research for constructing satellite based DGPS system.

  • PDF

DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법 (Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop)

  • 이기옥;유병규;유권종;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.