• Title/Summary/Keyword: Clinical parameters

Search Result 2,400, Processing Time 0.035 seconds

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF

Long-term Results of Taking Anti-oxidant Nutritional Supplement in Intermediate Age-related Macular Degeneration (중기 나이관련황반변성 환자에서 항산화영양제 복용 후 장기 관찰 결과)

  • Bang, Seul Ki;Kim, Eung Suk;Kim, Jong Woo;Shin, Jae Pil;Lee, Ji Eun;Yu, Hyeong Gon;Huh, Kuhl;Yu, Seung-Young
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1152-1159
    • /
    • 2018
  • Purpose: We prospectively investigated clinical changes and long-term outcomes after administration of the drugs recommended by the Age-Related Eye Disease Study-2 to patients with intermediate age-related macular degeneration (AMD). Methods: This prospective multicenter study enrolled 79 eyes of 55 patients taking lutein and zeaxanthin. The primary endpoint was contrast sensitivity; this was checked every 12 months for a total of 36 months after treatment commenced. The secondary endpoints were visual acuity, central macular thickness, and drusen volume; the latter two parameters were assessed using spectral domain optical coherence tomography. Results: The mean patient age was $72.46{\pm}7.16years$. Contrast sensitivity gradually improved at both three and six cycles per degree. The corrected visual acuity was $0.13{\pm}0.14logMAR$ and did not change significantly over the 36 months. Neither the central macular thickness nor drusen volume changed significantly. Conclusions: Contrast sensitivity markedly improved after treatment, improving vision and patient satisfaction. Visual acuity, central retinal thickness, and drusen volume did not deteriorate. Therefore, progression of AMD and visual function deterioration were halted.

The Effect of Photomodulation in Human Dermal Fibroblasts (피부 섬유아세포에서 광자극의 효과)

  • Kim, Mi Na;Kwak, Taek Jong;Kang, Nae Gyu;Lee, Sang Hwa;Park, Sun Gyoo;Lee, Cheon Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Skin is exposed to sunlight or artificial indoor light on a daily. The reached solar light on the earth surface consist of 50% visible light and 45% infrared (IR) except for ultra violet (UV). The negative effects of UV including UVB and UVA have been steadily investigated within the last decades. However, little is known about the effects of visible or IR light. In this study, we irradiated human dermal fibroblasts using light emitting diode (LED) to investigate the optimal parameter for enhancing cell growth and collagen synthesis. We found that red of 630 nm and green of 520 nm enhance the cell proliferation, but irradiation with purple and blue light exerts toxic effects. To examine the response of irradiation time and light intensity on the fibroblasts, cells were exposed to red or green light with intensities from 0.05 to $0.75mW/cm^2$. Procollagen secretion was increased of 1.4 fold by 10 min irradiation, while 30 min treatment decreased the collagen synthesis of dermal fibroblasts. Treatment with red of $0.3mW/cm^2$ and green of 0.15 and $0.3mW/cm^2$ resulted in enhancement of collagen mRNA. Lastly, we investigated the combinatorial effect of red and green light on dermal fibroblasts. The sequential irradiation of red and green light is an efficient way for the purpose of the increase in the number of fibroblasts than single light treatment. On the other hand, the exposure of red light alone was more effective method for enhancing of collagen secretion. Our study showed that specific light parameters accelerated cell proliferation, gene expression and collagen secretion on human dermal fibroblasts. In conclusion, we demonstrate that light exposure with specific parameter has beneficial effects on the function of dermal fibroblasts, and suggests the possibility of its cosmetically and clinical application.

Analysis of relationship between cracked tooth syndrome and occlusion using Q-ray and T-scan (큐레이(Q-ray)와 티스캔(T-scan)을 사용한 치아균열증후군(cracked tooth syndrome)과 교합 사이의 상관관계에 대한 분석)

  • Ahn, Do-Gwan;Choi, Jin-Woo;Kim, Yuseong;Pyo, Se-Wook;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.271-280
    • /
    • 2021
  • Purpose. The aim of this study was to evaluate the relationship between the patient's occlusion and a cracked tooth by using T-scan occlusal analysis and a quantitative light-induced fluorescence (QLF) technology. Materials and methods. This study was carried out on 51 patients having cracked teeth between January, 2019 and December, 2020. The tooth crack was determined with a Q-ray pen and QLF parameters (ΔFmax and ΔRmax) were obtained by a Q-ray software. T-scan tests were conducted to all subjects and then, the occlusal force and disclosing time were analyzed. Mann-Whitney U test was performed to compare the occlusal force and disclosing time between cracked teeth groups and contra-lateral normal teeth groups (α = .05). Mann-Whitney U test was performed to compare ΔFmax and ΔRmax according to the results of cold/bite tests (α = .05). A Spearman correlation analysis was run to determine the relationship between ΔFmax or ΔRmax and occlusal force or disclosing time (α=.05). Results. The mean occlusal force and disclosing time were significantly higher on cracked teeth than on normal teeth (P < .05). The ΔFmax or ΔRmax were not significantly different according to the results of cold/bite tests (P > .05). There was no correlation between ΔFmax or ΔRmax and occlusal force or disclosing time (P > .05). Conclusion. There was a significant relationship between occlusion and cracked tooth syndrome. QLF has the potential to be a valuable tool for the diagnosis of tooth crack in clinical practice.

The Effect of Distal Hooks in Thoracolumbar Fusion Using a Pedicle Screw in Elderly Patients (척추경 나사못을 이용한 고령 환자의 흉요추부 유합에서 원위부 갈고리의 효과)

  • Lee, Dong-Hyun;Kim, Sung-Soo;Kim, Jung-Hoon;Lim, Dong-Ju;Choi, Byung-Wan;Kim, Jin-Hwan;Kim, Jin-Hyok;Park, Byung-Ook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.83-91
    • /
    • 2017
  • Purpose: To investigate the clinical outcomes of distal hook augmentation using a pedicle screw in thoracolumbar fusion in elderly patients. Materials and Methods: This retrospective multicenter study recruited 20 patients aged 65 years or older, who underwent anterior support and long level posterior fusion in the thoracolumbar junction with a follow-up of one year. To assess the effect of distal hook augmentation, the patients were divided into two groups; the pedicle screw with hook group (PH group, n=10) and the pedicle screw alone group (PA group, n=10). Results: The average age was 72.4 years (65-83 years). The average fusion segment was 4.6 segments (3-6 segments). There were no significant differences in age, sex, causative diseases, bone mineral density of lumbar and proximal femur, number of patients with osteoporosis, and number of fused segments between the two groups (p≥0.05). At 1 year follow-up after surgery, parameters related with distal screw pullout were significantly worse in the PA group. No patients in the PH group had distal screw pullout. However, six patients (60%, 6/10) in the PA group had distal screw pullout. There were no significant differences in the progression of distal junctional kyphosis between the two groups. Conclusion: Distal hook augmentation is an effective procedure in protecting distal pedicle screws against the pullout when long level thoracolumbar fusion was performed in elderly patients aged 65 years or older.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

Development of Korean Version of Heparin-Coated Shunt (헤파린 표면처리된 국산화 혈관우회도관의 개발)

  • Sun, Kyung;Park, Ki-Dong;Baik, Kwang-Je;Lee, Hye-Won;Choi, Jong-Won;Kim, Seung-Chol;Kim, Taik-Jin;Lee, Seung-Yeol;Kim, Kwang-Taek;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • Background: This study was designed to develop a Korean version of the heparin-coated vascular bypass shunt by using a physical dispersing technique. The safety and effectiveness of the thrombo-resistant shunt were tested in experimental animals. Material and Method: A bypass shunt model was constructed on the descending thoracic aorta of 21 adult mongrel dogs(17.5-25 kg). The animals were divided into groups of no-treatment(CONTROL group; n=3), no-treatment with systemic heparinization(HEPARIN group; n=6), Gott heparin shunt (GOTT group; n=6), or Korean heparin shunt(KIST group; n=6). Parameters observed were complete blood cell counts, coagulation profiles, kidney and liver function(BUN/Cr and AST/ ALT), and surface scanning electron microscope(SSEM) findings. Blood was sampled from the aortic blood distal to the shunt and was compared before the bypass and at 2 hours after the bypass. Result: There were no differences between the groups before the bypass. At bypass 2 hours, platelet level increased in the HEPARIN and GOTT groups(p<0.05), but there were no differences between the groups. Changes in other blood cell counts were insignificant between the groups. Activated clotting time, activated partial thromboplastin time, and thrombin time were prolonged in the HEPARIN group(p<0.05) and differences between the groups were significant(p<0.005). Prothrombin time increased in the GOTT group(p<0.05) without having any differences between the groups. Changes in fibrinogen level were insignificant between the groups. Antithrombin III levels were increased in the HEPARIN and KIST groups(p<0.05), and the inter-group differences were also significant(p<0.05). Protein C level decreased in the HEPARIN group(p<0.05) without having any differences between the groups. BUN levels increased in all groups, especially in the HEPARIN and KIST groups(p<0.05), but there were no differences between the groups. Changes of Cr, AST, and ALT levels were insignificant between the groups. SSEM findings revealed severe aggregation of platelets and other cellular elements in the CONTROL group, and the HEPARIN group showed more adherence of the cellular elements than the GOTT or KIST group. Conclusion: Above results show that the heparin-coated bypass shunts(either GOTT or KIST) can suppress thrombus formation on the surface without inducing bleeding tendencies, while systemic heparinization(HEPARIN) may not be able to block activation of the coagulation system on the surface in contact with foreign materials but increases the bleeding tendencies. We also conclude that the thrombo-resistant effects of the Korean version of heparin shunt(KIST) are similar to those of the commercialized heparin shunt(GOTT).

  • PDF