• Title/Summary/Keyword: Clinical measurement method

Search Result 527, Processing Time 0.033 seconds

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

Diagnostic Value of Adenosine Deaminase(ADA) and its Isoenzyme in Pleural Effusion (흉수의 감별진단에서 Adenosine Deaminase (ADA) 및 동종효소의 유용성)

  • Kim, Keun-Youl;Kweon, Suk-Hoe;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Youn-Seup;Chun, Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.388-396
    • /
    • 1998
  • Background: Etiologic diagnosis of pleural effusion is usually made by clinical characteristics, pleural fluid analysis and pleural biopsy. But, despite careful diagnostic study, the cause of pleural effusion cannot be found in about 20 percent of patients, especially in loculated pleural effusions. Tuberculous pleurisy is one of the most common cause of pleural effusion in Korea. But, pleural fluid culture for Mycobacterium tuberculosis are positive in only 20 to 30 percent of patients and typical pleural biopsy finding in less than 50 percent of patients with this disease. In recent studies, adenosine deaminse(ADA) and its isoenzymes were proposed to be a useful diagnostic tool for differential diagnosis of pleural effusion. We investigated the pattern of ADA and its iscenzyme activities in various cause of pleural effusions to evaluate the diagnostic value of measuring ADA and its isoenzymes. Method: We measured total ADA and its isoenzyme activities in pleural fluid and serum from 54 patients with pleural effusion(25 tuberculous pleural effusion, 10 parapneumonic effusion, 14 malignant pleural effusion, 5 transudative pleural effusion), including 5 loculated tuberculous pleural effusions and 6 loculated parapneumonic effusions. Total ADA activity was measured by the spectrophotometric method and ADA2 isoenzyme activity was measured with same method using EHNA, potent inhibitor of ADA1 isoenzyme activity. Result: Total ADA activity of tuberculous pleural effusion was higher than malignant pleural effusion(p<0.01), but no significant difference was found between tuberculous pleural effusion and parapneumonic effusion(tuberculous pleural effusion: $148.9{\pm}89.9IU/L$, parapneumonic effusion: $129.0{\pm}119.4IU/L$, malignant pleural effusion: $48.7 {\pm}39.7IU/L$). Percentage of ADA2 activity to total ADA activity(ADA2%) of pleural effusion of tuberculous pleurisy was higher than parapneumonic effusion(p<0.05). but no significant difference was found between tuberculous pleural effusion and malignant pleural effusion(tuberculous pleural effusion: $57.2{\pm}10.7%$, parapneumonic effusion: $35.9{\pm}17.8%$, malignant pleural effusion: $60.7{\pm}4.1%$). In loculated pleural effusion, ADA2% of tuberculous pleural effusion was higher than parapneumonic effusion(tuberculous pleural effusion: $53.3{\pm}3.9%$, parapneumonic effusion: $27.8{\pm}7.9%$). Conclusion: Measurement of ADA isoenzyme activity is useful for differentiating tuberculous pleural effusion from parapneumonic effusion, especially in loculated pleural effusion.

  • PDF

The Empirical Exploration of the Conception on Nursing (간호개념에 대한 기초조사)

  • 백혜자
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.1
    • /
    • pp.65-87
    • /
    • 1981
  • The study is aimed at exploring concept held by clinical nurses of nursing. The data were collected from 225 nurses conviniently selected from the population of nurses working in Kang Won province. Findings include. 1) Nurse's Qualification. The respondents view that specialized knowledge is more important qualification of the nurse. Than warm personality. Specifically, 92.9% of the respondents indicated specialized knowledge as the most important qualification while only 43.1% indicated warm personality. 2) On Nursing Profession. The respondents view that nursing profession as health service oriented rather than independent profession specifically. This suggests that nursing profession is not consistentic present health care delivery system nor support nurses working independently. 3) On Clients of Nursing Care The respondents include patients, family and the community residents in the category of nursing care. Specifically, 92.0% of the respondents view that patient is the client, while only 67.1% of nursing student and 74.7% of herself. This indicates the lack of the nurse's recognition toward their clients. 4) On the Priority of Nursing care. Most of the respondents view the clients physical psychological respects as important component of nursing care but not the spiritual ones. Specially, 96.0% of the respondents indicated the physical respects, 93% psychological ones, while 64.1% indicated the spiritual ones. This means the lack of comprehensive conception on nursing aimension. 5) On Nursing Care. 91.6% of the respondents indicated that nursing care is the activity decreasing pain or helping to recover illness, while only 66.2% indicated earring out the physicians medical orders. 6) On Purpose of Nursing Care. 89.8% of the respondents indicated preventing illness and than 76.6% of them decreasing 1;ai of clients. On the other hand, maintaining health has the lowest selection at the degree of 13.8%. This means the lack of nurses' recognition for maintaining health as the most important point. 7) On Knowledge Needed in Nursing Care. Most of the respondents view that the knowledge faced with the spot of nursing care is needed. Specially, 81.3% of the respondents indicated simple curing method and 75.1%, 73.3%, 71.6% each indicated child nursing, maternal nursing and controlling for the communicable disease. On the other hand, knowledge w hick has been neglected in the specialized courses of nursing education, that is, thinking line among com-w unity members, overcoming style against between stress and personal relation in each home, and administration, management have a low selection at the depree of 48.9%,41.875 and 41.3%. 8) On Nursing Idea. The highest degree of selection is that they know themselves rightly, (The mean score measuring distribution was 4.205/5) In the lowest degree,3.016/5 is that devotion is the essential element of nursing, 2.860/5 the religious problems that human beings can not settle, such as a fatal ones, 2,810/5 the nursing profession is worth trying in one's life. This means that the peculiarly essential ideas on the professional sense of value. 9) On Nursing Services. The mean score measuring distribution for the nursing services showed that the inserting of machine air way is 2.132/5, the technique and knowledge for surviving heart-lung resuscitating is 2.892/s, and the preventing air pollution 3.021/5. Specially, 41.1% of the respondents indicated the lack of the replied ratio. 10) On Nurses' Qualifications. The respondents were selected five items as the most important qualifications. Specially, 17.4% of the respondents indicated specialized knowledge, 15.3% the nurses' health, 10.6% satisfaction for nursing profession, 9.8% the experience need, 9.2% comprehension and cooperation, while warm personality as nursing qualifications have a tendency of being lighted. 11) On the Priority of Nursing Care The respondents were selected three items as the most important component. Most of the respondents view the client's physical, spiritual: economic points as important components of nursing care. They showed each 36.8%, 27.6%, 13.8% while educational ones showed 1.8%. 12) On Purpose of Nursing Care. The respondents were selected four items as the most important purpose. Specially,29.3% of the respondents indicated curing illness for clients, 21.3% preventing illness for client 17.4% decreasing pain, 15.3% surviving. 13) On the Analysis of Important Nursing Care Ranging from 5 point to 25 point, the nurses' qualification are concentrated at the degree of 95.1%. Ranging from 3 point to 25, the priorities of nursing care are concentrated at the degree of 96.4%. Ranging from 4 point to 16, the purpose of nursing care is concentrated at the degree of 84.0%. 14) The Analysis, of General Characteristics and Facts of Nursing Concept. The correlation between the educational high level and nursing care showed significance. (P < 0.0262). The correction between the educational low level and purpose of nursing care showed significance. (P < 0.002) The correlation between nurses' working yeras and the degree of importance for the purpose of nursing care showed significance (P < 0.0155) Specially, the most affirmative answers were showed from two years to four ones. 15) On Nunes' qualification and its Degree of Importance The correlation between nurses' qualification and its degree of importance showed significance. (r = 0.2172, p< 0.001) 0.005) B. General characteristics of the subjects The mean age of the subject was 39 ; with 38.6% with in the age range of 20-29 ; 52.6% were male; 57.9% were Schizophrenia; 35.1% were graduated from high school or high school dropouts; 56.l% were not have any religion; 52.6% were unmarried; 47.4% were first admission; 91.2% were involuntary admission patients. C. Measurement of anxiety variables. 1. Measurement tools of affective anxiety in this study demonstrated high reliability (.854). 2. Measurement tools of somatic anxiety in this study demonstrated high reliability (.920). D. Relationship between the anxiety variables and the general characteristics. 1. Relationship between affective anxiety and general characteristics. 1) The level of female patients were higher than that of the male patient (t = 5.41, p < 0.05). 2) Frequencies of admission were related to affective anxiety, so in the first admission the anxiety level was the highest. (F = 5.50, p < 0.005). 2, Relationship between somatic anxiety and general characteristics. 1) The age range of 30-39 was found to have the highest level of the somatic anxiety. (F = 3.95, p < 0.005). 2) Frequencies of admission were related to the somatic anxiety, so .in first admission the anxiety level was the highest. (F = 9.12, p < 0.005) 0. Analysis of significant anxiety symptoms for nursing intervention. 1. Seven items such as dizziness, mental integration, sweating, restlessness, anxiousness, urinary frequency and insomnia, init. accounted for 96% of the variation within the first 24 hours after admission. 2. Seven items such as fear, paresthesias, restlessness, sweating insomnia, init., tremors and body aches and pains accounted for 84% of the variation on the 10th day after admission.

  • PDF

Relationship between exhaled nitric oxide and pulmonary function test in children with asthma (소아 천식에서 호기산화질소와 폐기능 검사의 관계)

  • Ko, Han-Seok;Chung, Sung-Hoon;Choi, Yong-Sung;Choi, Sun-Hee;Rha, Yeong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.181-187
    • /
    • 2008
  • Purpose : Asthma is characterized by reversible airway obstruction and bronchial hyperresponsiveness result from airway inflammation. Fraction of nitric oxide in expired air (FeNO) has recently been investigated as a noninvasive measure of airway inflammation. FeNO has been reported to correlate with induced sputum eosinophilia and methacholine challenge test that it is represent severity of asthma. The purpose of this study was to analyze the relationship of FeNO with pulmonary function tests in patients with intermittent asthma. Methods : Eighty children included in this study were diagnosed as asthma from April through August, 2005 in Department of Pediatrics, College of Medicine, Kyunghee University. They aged from 4 to 15 years who were able to conduct spirometry and FeNO monitoring. They did not have upper respiratory tract infection and did not use an asthma controller which contain corticosteroids within 4 weeks. Pulmonary function test was done and FeNO was measured with online tidal breathing method using a chemiluminescence NO analyzer (CLD 88 sp, Eco Medics, Duernten, Switzerland). The correlations between pulmonary function test and FeNO were analyzed using Spearman correlation coefficient method. Results : The mean of FeNO of subject was 16.88 parts per billion (ppb). The mean of forced expiratory volume in 1 second ($FEV_1$) was $0.890{\pm}0.455L$ and forced vital capacity (FVC) was $1.071{\pm}0.630L$. The mean of predicted $FEV_1%$ ($FEV_1%pred$) was $98.39{\pm}34.27%$ and $FEV_1/FVC$ was $88.53{\pm}19.49$. FeNO was significantly correlate with $FEV_1$ (r=0.345, P<0.01) and FVC (r=0.244, P<0.05). FeNO did not correlate with $FEV_1%pred$ or $FEV_1/FVC$. Conclusion : The measurement of FeNO could be a useful marker in the management of childhood asthma and it is evolving to provide a complementary role alongside existing pulmonary function test. We propose that measuring technique and establishment of normal reference range are important area for future research.

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

The clinical study of colonic transit time stimulated manual acupuncture and electo-acupuncture(ST25, ST37) (천추(天樞) 및 상거허(上巨虛)의 침자극(針刺棘)이 대장(大腸) 통과시간(通過時間)에 미치는 영향(影響))

  • Kim Dong-Woung;Lee Sang-Yung;Lee Chang-Hyun
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.311-318
    • /
    • 1998
  • Amis:ST25(Chonchu) and ST37(Sanggoho) are usually used acupoints to management several disease which induced to abnormal intestinal motility as diarrhea, constipation. Colonic transit time by radio opaque marker is able to study easily and useful method for evaluation of colonic motility. The aim of this study was to assess the effect on colonic transit time by manual acupuncture or electroacupuncture stimulation of ST25, ST37 in normal adult. Method: Colonic transit time, including Rt colon, Lt colon, rectosigmoid colon was measured by radio opaque marker in 11 normal adults. Colon transit time was measured before stimulation and after stimulation on ST25, ST37 by manual acupuncture and electroacupuncture. Each person was treated manual acupuncture or electroacupuncture stimulation for 3 days before colonic transit time measurement with 1 week interval. Result: Colon transit time before stimulation was measured $10.60{\pm}12.11$, $3.92{\pm}7.72$, $3.27{\pm}6.37$, $3.41{\pm}5.57$ hours total colon, Rt colon, Lt colon, rectosigmoid colon, respectively. Colon transit time after manual acupuncture is measured $10.48{\pm}12.35$, $3.72{\pm}7.52$, $3.37{\pm}6.76$, $3.39{\pm}5.84$ hours total colon, Rt colon, Lt colon, rectosigmoid colon, respectively. Colon transit time after electroacupuncture stimulation is measured $10.30{\pm}13.21$, $3.92{\pm}8.02$, $3.07{\pm} $, $3.31{\pm}5.49$ hours total colon, Rt colon, Lt colon, rectosigmoid colon, respectively. Significant change was observed Lt colon transit time after electroacupuncture as compared before acupuncture(P<0.05). Conclusion: Theses results suggest that manual acupuncture and electroacupuncture of ST25, ST37 in normal adults does not change colonic transit time.

  • PDF

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Method Development for the Profiling Analysis of Endogenous Metabolites by Accurate-Mass Quadrupole Time-of-Flight(Q-TOF) LC/MS (LC/TOFMS를 이용한 생체시료의 내인성 대사체 분석법 개발)

  • Lee, In-Sun;Kim, Jin-Ho;Cho, Soo-Yeul;Shim, Sun-Bo;Park, Hye-Jin;Lee, Jin-Hee;Lee, Ji-Hyun;Hwang, In-Sun;Kim, Sung-Il;Lee, Jung-Hee;Cho, Su-Yeon;Choi, Don-Woong;Cho, Yang-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.388-394
    • /
    • 2010
  • Metabolomics aims at the comprehensive, qualitative and quantitative analysis of wide arrays of endogenous metabolites in biological samples. It has shown particular promise in the area of toxicology and drug development, functional genomics, system biology and clinical diagnosis. In this study, analytical technique of MS instrument with high resolution mass measurement, such as time-of-flight (TOF) was validated for the purpose of investigation of amino acids, sugars and fatty acids. Rat urine and serum samples were extracted by selected each solvent (50% acetonitrile, 100% acetonitrile, acetone, methanol, water, ether) extraction method. We determined the optimized liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) system and selected appropriated columns, mobile phases, fragment energy and collision energy, which could search 17 metabolites. The spectral data collected from LC/TOFMS were tested by ANOVA. Obtained with the use of LC/TOFMS technique, our results indicated that (1) MS and MS/MS parameters were optimized and most abundant product ion of each metabolite were selected to be monitorized; (2) with design of experiment analysis, methanol yielded the optimal extraction efficiency. Therefore, the results of this study are expected to be useful in the endogenous metabolite fields according to validated SOP for endogenous amino acids, sugars and fatty acids.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF