• Title/Summary/Keyword: Cleaning time

Search Result 619, Processing Time 0.027 seconds

Enhancement of Data Retention Time in DRAM through Optimization of Sidewall Oxidation Precleaning (측면산화 프리크리닝의 최소화를 통한 DRAM의 데이터 유지시간 개선)

  • Chai, Yong-Yoong;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.833-837
    • /
    • 2012
  • This paper proposes a DRAM data retention time enhancement method that minimizes silicon loss and undercut at STI sidewall by reducing the SC1 (Standard Cleaning) time. SC1 time optimization debilitates the parasitic electric field in STI's top corner, which reduces an inverse narrow width effect to result in reduction of channel doping density without increasing the subthreshold leakage of cell Tr. Moreover, it minimizes the electric field in depletion area from cell junction to P-well, increasing yield or data retention time.

Removal of Organic Wax and Particles on Final Polished Wafer by Ozonated DI Water

  • Yi, Jae-Hwan;Lee, Seung-Ho;Kim, Tae-Gon;Lee, Gun-Ho;Choi, Eun-Suck;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.18 no.6
    • /
    • pp.307-312
    • /
    • 2008
  • In this study, a new cleaning process with a low cost of ownership (CoO) was developed with ozonated DI water ($DIO_3$). An ozone concentration of 40 ppm at room temperature was used to remove organic wax film and particles. Wax residues thicker than $200\;{\AA}$ remained after only a commercial dewaxer treatment. A $DIO_3$ treatment in place of a dewaxer showed a low removal rate on a thick wax layer of $8000\;{\AA}$ due to the diffusion-limited reaction of ozone. A dewaxer was combined with a $DIO_3$ rinse to reduce the wax removal time and remove wax residue completely. Replacing DI rinse with the $DIO_3$ rinse resulted in a surface with a contact angle of less than $5^{\circ}$, which indicates no further cleaning steps would be required. The particle removal efficiency (PRE) was further improved by combining a SC-1 cleaning step with the $DIO_3$ rinsing process. A reduction in the process time was obtained by introducing $DIO_3$ cleaning with a dewaxing process.

Comparison of Detergency and Fabric Deformation between Ultrasonic and Home Laundry (초음파 세탁과 가정 세탁의 세척성과 직물변형 비교)

  • Nawon Hwang;Hae-won Chung;Kwang-Woo Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.3
    • /
    • pp.386-397
    • /
    • 2023
  • In this study, the efficacy of ultrasonic washing in cotton and wool fabrics was compared and evaluated against conventional washing in terms of cleaning properties and fabric deformation. Factors such as washing temperature, time, liquid ratio, and detergent concentration were kept varied, and the cleaning properties of sebum-soiled fabrics were assessed using different detergents such as alcohol ethoxylate, linear alkylbenzenesulfonate, and IEC 60456 Reference Detergent A*. In addition, the effects and emulsification power of enzymes and oxygen bleach were examined. To compare the cleaning properties with general washing, a launder-O-meter was used. To investigate fabric deformation during the washing process, the loosening test cloth, shrinkage test cloth, and mechanical strength test cloth were compared between ultrasonic washing machines and household drum washing machines. The results indicate that ultrasonic washing exhibits superior cleaning properties than launder-O-meter when the temperature is low and the washing time is short. Furthermore, there is less deformation and damage during the washing process. It was also observed that the activity of the detergent increases when ultrasonic waves are applied to the washing process. Considering the increasing tendency to pursue convenience and simplicity in clothing management as well as the anticipated commercialization of smart clothing with built-in electric circuits, ultrasonic laundry could serve as a new alternative to existing laundry methods.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Relationship between Exposure Concentrations to Methylene Chloride in Air and Carboxyhemoglobin Levels in Blood of Workers Engaged in Blowing, and Cleaning Operations (발포 및 세척 공정 근로자의 공기중 Methylene Chloride 노출 농도와 혈중 Carboxyhemoglobin 수준간의 상관관계에 관한 연구)

  • Shin, Yong Chul;Kim, Yang Ho;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 1999
  • The objectives of this study were to evaluate exposures to airborne methylene chloride and postshift carboxyhemoglobin (COHb) in blood of workers engaged in processes using blowing or cleaning agents, and to investigate correlation between methylene chloride concentrations and the blood COHb levels of workers. The geometric mean (GM) of workers' exposures (8 hour-time weighted averages, TWA) to airborne methylene chloride during cleaning molds using rags wetted with the solvent in the manufacture of flexible polyurethane foam (GM = 61.4 ppm), during operating the dip tank for cleaning molds in the manufacture of lens (GM = 61.0 ppm), and during cleaning the blowing nozzles by spraying the solvent in the manufacture of shoes (GM = 117.2 ppm) were exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$)-Time Weighted Average (TWA) (50 ppm). The COHb levels were significantly different among groups (p<0.05). The average COHh levels in blood of non-smoking workers were 2.0% in. low-level (<50 ppm) exposure group, and 3.9 % in high-level (>50ppm) exposure group. The average COHb levels in smoking workers were 3.1% in low-level exposure group, and 4.8% in high-level exposure group. The blood COHb levels of no-exposed workers to methylene chloride were 1.8% in non-smoking group, and 2.8% in smoking group. It was found that the COHb level dependeds on the methylene chloride concentration and smoking habit, and was highly correlated with methylene chloride concentration in air. The correlation coefficient was 0.81 among non-smoking workers. The estimated COHb level (3.6%) and 95% upper confidence limit (4.0%) corresponding to TLV-TWA of methylene chloride exceeded the current ACGIH Biological Exposure Index (COHb 3.5%) for carbon monoxide. The estimated COHb level (5.4%) at 100 ppm exceeded the standard (5%) recommended by National Institute for Occupational Safety and Health (NIOSH) for preventing adverse cardiovascular effect. The estimated COHb value and 95% upper confidence limit at 25 ppm of the Occupational Safety and Health. Adminstration (OSHA) Permissible Exposure Limit-TWA (PEL-TWA) were 2.6% and 3.0%, respectively. It is suggested that COHb in blood be kept below 3.0% to comply with OSHA PEL-TWA.

  • PDF

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.

Study on the Exposure Levels of Organic Solvents and Subjective Symptoms of Dry-cleaning Workers (드라이클리닝 근로자들의 유기용제 폭로와 자각증상)

  • Kim, Soo-Young;Kim, Jeong-Yun;Lee, Yeon-Kyeng;Lee, Sok-Goo;Lee, Young-Soo;Cho, Young-Chae;Lee, Tae-Young;Lee, Dong-Bae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.628-643
    • /
    • 1998
  • To investigate the exposure levels of organic solvents and subjective symptoms of dry-cleaning workers, 77 male and 52 female dry-cleaning workers who had been worked in a small city of Chungnam province, and a large city, Taejon were selected for the study group. Air concentrations of organic solvents in the working environment were analyzed, and subjective symptoms of dry-cleaning workers were surveyed, from July to August 1996. The results obtained were as follows : 1. The concentrations of organic solvents in the working environment were within permissible TLV-TWA limits. 2. For the 13 symptom clusters, the most frequently complained symptom clusters were fatigue as 71.3%, and followed by depression and urinary disturbances as 53.5% and 51.9%. Other symptom clusters complained were below 50%. 3. Positive response rates of subjective symptoms were significantly higher in worker groups such as lived in a large city, female, higher education level, more frequently alcohol drinking, higher concentration of organic solvent in working environment, work in alone. 4. Workers who had used solvent B showed 2.3 point higher scores of subjective symptoms than those of solvent A. Of the subjective symptoms scores, amnesia and nervousness were higher in solvent B user group than solvent B user group. 5. As a result of factor analysis, 3 factors such as depression, urinary disturbance and neurologic disturbance were selected. 6. As a result of the logistic regression analysis, sex, the number of fellow workers, working time, region, job tenure, smoking, alcohol drinking, ventilating system, concentration of organic solvent in working environment and place of residence were selected for the related variables. For the conclusion, even though the concentrations of organic solvents in the working environments of dry-cleaning workers were within permissible limit of TLV-TWA, many dry-cleaning workers complained symptoms, such as fatigue, depression, urinary disturbances and so on. And the factors affecting to the symptoms of dry-cleaning workers were the number of fellow workers, work hours, region, job tenure, smoking and alcohol drinking.

  • PDF

A Study on Patients' satisfaction for quality improvement of Physical Therapy service (물리치료실의 질 향상(QI)을 위한 내원 환자의 만족도에 관한 연구)

  • Kwon, Chun-Suk;Han, Dang-Uck
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.483-494
    • /
    • 2000
  • The purpose of this study was to contribute to quality improvement with physical therapy service and determining the factors affecting patients' satisfaction. The study subjects were ambulatory and admitted patients treated with physical therapy at B general hospital located in Taejon from July 15, 2000 to July 21. Authors developed structured questionnaire, and distributed it to each physical therapist of B general hospital. Total number of distributed questionnaire was 164, and 157 questionnaire were collected and analysed finally. Demand of physical therapy for quality improvement(QI) related to treatment time(r =0.746, P<01), treatment method(r =.664, P<.01). treatment effect(r=0.648, P<.01), equipments(r=0.620, P<.01), cleaning status(r =0.619, P<.01). Willingness to revisit and recommendation of this physical therapy room related to treatment method(r=0.489, P<.01), treatment time(r=0.469, P<.01), cleaning status(r=0.432, P<.01).

  • PDF

Development of new cleaning technology using ionized water by electrolysis (전기분해 이온수를 이용한 세정기술 개발)

  • 변문기;백희원;조봉희;김영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.617-620
    • /
    • 1999
  • To reduce the consumption of chemicals and ultra pure water(UPW) in cleaning process used in device manufacturing, we proposed wet processes that use electrolytic ionized water(EIW), which is generated by electrolysis of a diluted electrolyte solution or UPW and systemically investicate the EIW\`s characteristics. EIW\`s pH values are increased in cathode chamber and decreased in anode chamber according to the electrolysis time and its varied ratio is reduced with time increasement. The variation of pH and ORP is increased accordin to the applied voltage until critical voltage. But more than that voltage, the variation is decreased because of ion\`s scattering effect. When electrolyte is added, the effects of electrolysis is increased because electrolyte acts as catalyst. But when the density of electrolyte is increased more than critical value, ion\`s flowage is obstructed and the effects of electrolysis is decreased.

  • PDF

Data Cleaning and Integration of Multi-year Dietary Survey in the Korea National Health and Nutrition Examination Survey (KNHANES) using Database Normalization Theory (데이터베이스 정규화 이론을 이용한 국민건강영양조사 중 다년도 식이조사 자료 정제 및 통합)

  • Kwon, Namji;Suh, Jihye;Lee, Hunjoo
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.298-306
    • /
    • 2017
  • Objectives: Since 1998, the Korea National Health and Nutrition Examination Survey (KNHANES) has been conducted in order to investigate the health and nutritional status of Koreans. The food intake data of individuals in the KNHANES has also been utilized as source dataset for risk assessment of chemicals via food. To improve the reliability of intake estimation and prevent missing data for less-responded foods, the structure of integrated long-standing datasets is significant. However, it is difficult to merge multi-year survey datasets due to ineffective cleaning processes for handling extensive numbers of codes for each food item along with changes in dietary habits over time. Therefore, this study aims at 1) cleaning the process of abnormal data 2) generation of integrated long-standing raw data, and 3) contributing to the production of consistent dietary exposure factors. Methods: Codebooks, the guideline book, and raw intake data from KNHANES V and VI were used for analysis. The violation of the primary key constraint and the $1^{st}-3rd$ normal form in relational database theory were tested for the codebook and the structure of the raw data, respectively. Afterwards, the cleaning process was executed for the raw data by using these integrated codes. Results: Duplication of key records and abnormality in table structures were observed. However, after adjusting according to the suggested method above, the codes were corrected and integrated codes were newly created. Finally, we were able to clean the raw data provided by respondents to the KNHANES survey. Conclusion: The results of this study will contribute to the integration of the multi-year datasets and help improve the data production system by clarifying, testing, and verifying the primary key, integrity of the code, and primitive data structure according to the database normalization theory in the national health data.