• Title/Summary/Keyword: Cleaning power

Search Result 280, Processing Time 0.036 seconds

Development of a High-power Ultrasonic System for Sonochemistry Reaction (음향화학 반응용 강력초음파 개발)

  • Lee, Yang-Lae;Kim, Hyun-Se;Baek, Min-Hyuck
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.142-148
    • /
    • 2013
  • High-power ultrasonic promotes a chemical reaction by its own energy, thus it has been used for sonochemistry applications. For example, it has been mostly used for mixing, reaction catalyst, dispersion and disintegration. High-power ultrasonic transducer is made with structure based on a Bolt-clamped Langevin type Transducer (BLT), But it has difficulty in the development because degradation of piezoelectric ceramic by the heat generation of BLT. In this study, for a development of the transducer of 25 kHz and 1000 W used in sonochemistry and industrial cleaning, BLT with a hole in its center and tubular type waveguide of the transducer were designed based on finite element method (FEM). The transducer was fabricated based on the design parameter, and the impedance characteristics are measured experimentally and compared with the numerical results.

MV Cable Failure Statistics Analysis and Failure Rate Utilization Method of Prioritization of Diagnosis Targets (지중 배전용케이블 고장통계 분석 및 고장률 활용 진단대상 우선순위 선정방법)

  • Cho, Chong-Eun;Lee, On-You;Kim, Sang-Bong;Kim, Kang-Sik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.263-268
    • /
    • 2021
  • This paper statistically analyzes the time required for each failure cause and describes a diagnostic method for 159 reports of failure analysis of MV cables that occurred in the distribution system of KEPCO over the past 18 years. In addition, the manufacturer's failure rate compared to 100C-km was calculated using 381 cases of MV cable deterioration failure between 2008 and 2020. It is hoped that this paper will help those in charge of maintaining underground facilities at the business office to use the failure rate to prioritize facility diagnosis.

The Development of Cleaning and Monitoring System for Pipeline Type UV Sterilizer (관로형 UV 소독기를 위한 세척 및 모니터링 시스템 개발)

  • Park, Byeung-Jun;Ryu, Ji-Hyoung;Park, Jae-Byung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6434-6440
    • /
    • 2013
  • In this paper, an integrated control system is proposed for automatic control and remote monitoring of pipeline type UV sterilizer. The proposed system can control the cleaning wiper in the sterilizer with various cleaning motions, and periodically check the contamination level of the UV lamps with the UV power sensors. Therefore, sterilizer repair and maintenance can be more effectively done. In addition, the control system based on the open-source processor can communicate with external smart devices via Bluetooth, and thus wirelessly exchange control commands and sensor data. Furthermore, the system is able to flexibly cope with changes of cleaning motions and sensors since its firmware can be wirelessly upgraded by using the smart device. Consequently, the proposed system is suitable to construct a smart sewage treatment system in small towns.

Development of Confined Plasma Source for Hazardous Gas Treatment (유해가스 처리를 위한 Confined Plasma Source 개발)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.135-140
    • /
    • 2020
  • Since the process gas that is essential in the semiconductor process is a harmful gas, it is an essential task to solve it in an environmentally friendly manner. Currently, the cleaning technology used in the semiconductor process is mostly a wet cleaning based on hydrogen peroxide developed in the 1970s, and the SC-1 cleaning liquid for removing particles on the surface uses a mixture of ammonia and hydrogen peroxide. Therefore, environmental problems are caused, and economic problems caused by excessive water use are also serious. For this reason, the products developed through this study are used to decompose the process harmful gas from the chamber outlet into a harmless gas before entering the vacuum pump, or by incineration and the gaseous components are deposited on the pump. I want to solve the problem. In this paper, CPS (Confined Plasma Source) is proposed to save environment and improve productivity by replacing harmful gases (N2, CF4, SF6⋯., Etc) which are indispensable in semi-contamination process with innocuous gases or incineration with plasma, to study.

Wireless Sensor Network Design for Industrial Applications and the Sound Wave Detection in Acoustic Cleaning Systems (산업용 무선센서네트워크 설계와 음향 세척 장치의 음파 검출을 위한 응용)

  • Kim, A Yeon;Han, Jae Jun;Kim, Dong Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.223-229
    • /
    • 2014
  • The acoustic cleaning system is widely used to remove foreign materials in factories, such as thermal power plants and incinerators. However, the acoustic cleaning systems tend to be clogged by foreign materials. In this paper, we develop a wireless sensor network for the sound wave detection in order to monitor proper operations in the acoustic cleaning systems. We observe that the developed wireless sensor network for the wave detection shows a stable operation in various industrial environments of wide temperature ranges. We also develop a data gathering device, which displays the current status of the sound generator and several values detected from the wireless sensor.

Eddy Covariance Measurement of CH4 Flux in a Rice Paddy in Gimje, Korea (김제 논에서 메탄 플럭스의 에디 공분산 관측)

  • Talucder, Samiul Ahsan;Yun, Juyeol;Kang, Namgoo;Shim, Kyo Moon;Kim, Joon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2013.11a
    • /
    • pp.28-29
    • /
    • 2013
  • We have been measuring $CH_4$ flux in a rice paddy in Gimje using the eddy covariance method since July 2011. In order to measure the fast fluctuations of $CH_4$ concentration, an innovative LI-7700 open-path laser spectrometer is used. This high-precision, low power, light weight, low maintenance sensor enables us to operate it on a continuous and long-term basis. One particular feature, among other things, is the self-cleaning lower mirror which decreases maintenance requirements while ensuring more robust, continuous, high-quality dataset. Its cleaning is initiated at user-specified time intervals or a signal strength threshold, and its status is recorded as a diagnostic index. We have noticed that the operation of LI-7700 at Gimje site is quite challenging particularly due to its frequent mirror cleaning requirement and the associated sensitivity of the instrument. In this presentation, we present some field observation data regarding the mirror cleaning and their analysis, thereby suggesting the pertinent operation options for high-quality, maximum data retrieval in the field.

  • PDF

Comparison of Detergency and Fabric Deformation between Ultrasonic and Home Laundry (초음파 세탁과 가정 세탁의 세척성과 직물변형 비교)

  • Nawon Hwang;Hae-won Chung;Kwang-Woo Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.3
    • /
    • pp.386-397
    • /
    • 2023
  • In this study, the efficacy of ultrasonic washing in cotton and wool fabrics was compared and evaluated against conventional washing in terms of cleaning properties and fabric deformation. Factors such as washing temperature, time, liquid ratio, and detergent concentration were kept varied, and the cleaning properties of sebum-soiled fabrics were assessed using different detergents such as alcohol ethoxylate, linear alkylbenzenesulfonate, and IEC 60456 Reference Detergent A*. In addition, the effects and emulsification power of enzymes and oxygen bleach were examined. To compare the cleaning properties with general washing, a launder-O-meter was used. To investigate fabric deformation during the washing process, the loosening test cloth, shrinkage test cloth, and mechanical strength test cloth were compared between ultrasonic washing machines and household drum washing machines. The results indicate that ultrasonic washing exhibits superior cleaning properties than launder-O-meter when the temperature is low and the washing time is short. Furthermore, there is less deformation and damage during the washing process. It was also observed that the activity of the detergent increases when ultrasonic waves are applied to the washing process. Considering the increasing tendency to pursue convenience and simplicity in clothing management as well as the anticipated commercialization of smart clothing with built-in electric circuits, ultrasonic laundry could serve as a new alternative to existing laundry methods.

Development of Cleaning Robot Based on PWMC to Optimized for the In-Pipe Cleaning (배관 청소에 최적화된 PWMC 기반 청소로봇 개발)

  • Han, Min-Seok;Lee, Yoon-Geon;Kim, Jae-Uk;Choi, Byeong-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.129-130
    • /
    • 2014
  • 본 논문은 배관 청소에 최적화된 PWMC 기반 청소로봇 개발을 제안한다. 제안하는 배관 청소로봇은 최적화된 배관 청소 환경을 제공하기 위하여 배관 요소를 분석하여 이에 따른 모터, 조인트, 솔, 스프링 등을 설계하였다. 설계를 통하여 개발된 청소로봇은 조정에 따라 지름 200~300mm의 좁은 배관에서 PWMC 를 통하여 속도를 제어하여 자동 청소가 가능하다. 또한 개발된 청소로봇은 6.8kg로 기존 배관 청소 기계를 50%이상 경량화 하여 휴대성과 간편한 조작에 따른 편의성을 제공하며, 기존의 장비에 대한 소모성을 낮추고 무게의 경량화 및 동작 자동화에 초점을 두었다.

  • PDF

Preparation of Chemical Solution for the Provisional Cement Remnant Cleaning in Dental Crown (치과 보철용 크라운에 잔존하는 임시 시멘트의 용해액의 개발)

  • Yi, Yong-Hyun;Kim, Byung-Jin;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.37 no.1
    • /
    • pp.12-15
    • /
    • 2017
  • It is important in dentistry that the provisional cement should be cleaned thoroughly from the crown before definitive cementation. The provisional cement has been removed by physical means such as curette, scaler, pumice, or sand-blasting with alumina particles, which is time-consuming, irritating, tedious, even causing crack. To avoid such troubles occurring through such physical cleaning means, the chemical solutions for dissolving the provisional cement remaining in dental crown were prepared, and solubilizing power of the solutions was measured and compared. The solution composed of MEA, NaOH, chloride chemicals ($CHCl_3$, $CCl_4$, $CH_2Cl_2$), surfactants (Igepal, Tween20), chelating agent (EDTA), and Ethyl cellosolve was most effective for dissolving the provisional cement.

Dissolution Characteristics of Copper Oxide in Gas-liquid Hybrid Atmospheric Pressure Plasma Reactor Using Organic Acid Solution

  • Kwon, Heoung Su;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.229-233
    • /
    • 2022
  • In this study, a gas-liquid hybrid atmospheric pressure plasma reactor of the dielectric barrier discharge method was fabricated and characterized. The solubility of copper oxide in the organic acid solution was increased when argon having a larger atomic weight than helium was used during plasma discharge. There was no significant effect of mixing organic acid solutions under plasma discharge treatment on the variation of copper oxide's solubility. As the applied voltage for plasma discharge and the concentration of the organic acid solution increased, the dissolution and removal power of the copper oxide layer increased. Solubility of copper oxide was more affected by the concentration in organic acid solution rather than the variation of plasma applied voltage. The usefulness of hybrid plasma reactor for the surface cleaning process was confirmed.