• Title/Summary/Keyword: Cleaning equipment

Search Result 201, Processing Time 0.024 seconds

A Study on Tunnel Cleaning Automation Equipment & Introducing Advanced Tunnel Cleaning Automation Equipment (터널 청소장비의 고찰 및 개선된 모델에 관한 연구)

  • Lee, Tai-Sik;Jang, Kyung-Soo;Koo, Ja-Kyung;Park, Kyung-Soon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.669-673
    • /
    • 2006
  • Field works are decreasing gradually since advancement of industrial robots. Tunnel cleaning is a dangerous field work which can be solved only by introducingadvanced tunnel cleaning automation equipment. Industrial robots work tirelessly night and day without a loss in performance. Consequently, greatly reduce the costs of manufactured goods.So far only 200 construction robots are invented. Robots used for tunnel cleaning are not of high standard they always need additional workers for job to be done. Robots offer specific benefits to workers, industries and countries. If introduced correctly for tunnel cleaning, industrial robots can improve the quality of life by freeing workers from dirty, boring, dangerous and heavy labor. Development of advanced tunnel cleaning automation equipment is a must to overcome above issues. The benefits of robots to industry include improved management control, productivity and consistently high quality products. This research is a study on tunnel cleaning automation equipment and introducing advanced tunnel cleaning automation equipment.

  • PDF

Development of LGP Dry Cleaning Equipment using ESD and Adhesive Roll (ESD와 점착 롤 제진을 이용한 LGP 건식 세정 장치 개발)

  • Ku, Ja-Yl;Jun, SungHo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.195-201
    • /
    • 2014
  • In this paper, we developed a LGP(Light Guide Panel) dry cleaning system for particle cleaning using corona discharge and dry adhesive roll. Therefore, we design a cleaning mechanism that can be applied dry adhesive dust removal roll and ESD(electrostatic discharge) by using corona discharge. Also, we design and implementation of equipment, which can loading, unloading and transfer LGP automatically. The developed equipment is dust and particle cleaning experimental results to demonstrate its stability.

Comparison of Equipment Contamination Level according to Enteral Nutrition Bag Cleaning and Disinfection Methods (경장영양백 세척 및 소독방법에 따른 오염 정도 비교)

  • Park, Jin-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.472-479
    • /
    • 2011
  • Purpose: The purpose of this study was to develop guidelines for cleaning of enteral nutrition bags by comparing the level of equipment contamination according to cleaning and disinfection methods. Method: This study was a true-experimental study, with 60 cases in total. Twenty cases each were randomly assigned to tepid water, detergent and brush, and disinfectant groups. The period of the experiment was March to April 2010, and enteral nutrition was given for 1 houre, 3 times a day at 7AM, noon, and 7PM for seven days. Enteral nutrition bags were cleaned after each feeding according to assigned cleaning and disinfection method followed by microbial cultures on 4th and 8th day before the 7AM feeding. Results: After 3 days of feeding and cleaning, the level of contamination of bags was not significantly different among the three groups. After seven days, the level of contamination was significantly lower when bags were cleaned with detergent and brush or with disinfectant compared to cleaning with tepid water. Conclusion: In cases where enteral nutrition bags are reused for example, in home care settings, studying findings indicate that cleaning bags using detergent and brush or disinfectant is an effective way to prevent contamination of bags.

Investigation of Job Satisfaction and Hazardous Factors of Aircraft Cleaning Worker (항공기 청소 노동자의 작업 만족도 및 유해인자 조사)

  • Choi, Yeonhak;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.174-184
    • /
    • 2020
  • Objectives: The purpose of this study was to improve the working environment by identifying the work satisfaction of the cleaning workers of the aircraft and measuring and assessing the harmful factors of the cleaning process. Methods: We asked 23 cleaning companies for questionnaires and got 100 answers from 5 companies. The A-E Airline health manager has been contacted to establish a site survey schedule. The in-flight and lounge were measured using direct reading equipment. The harmful factor to be measured are noise, dust, temperature, volatile organic compound, total airborne bacteria, and total airborne bacteria. Results: Uncomfortable positions when replacing blanket, cleaning the table, and cleaning the floor have been identified as factor that reduce work satisfaction. Noise when replacing newspapers and cleaning toilets has been identified as a factor that lowers work satisfaction. Temperature and humidity were found to reduce work satisfaction during in-flight disinfection. Measurements of aircraft cabin and lounge with direct read equipment have shown that none of the items exceed the exposure criteria. Conclusions: As a result of measuring direct-reading equipment, no items exceeded the exposure criteria for each harmful factor. A clear survey of the working environment is required based on the results, and additional research is needed using personal sample measurement.

Analysis of Variables Effects in 300mm PECVD Chamber Cleaning Process Using NF3

  • Sang-Min Lee;Hee-Chan Lee;Soon-Oh Kwon;Hyo-Jong Song
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2024
  • NF3, Chamber cleaning gas, has a high Global Warming Potential (GWP) of 17,000, causing significant greenhouse effects. Reducing gas usage during the cleaning process is crucial while increasing the cleaning Rate and reducing cleaning standard deviation (Stdev). In a previous study with a 6-inch PECVD chamber, a multiple linear regression analysis showed that Power and Pressure had no significant effect on the cleaning Rate because of their P-values of 0.42 and 0.68. The weight for Flow is 11.55, and the weights for Power and Pressure are 1.4 and 0.7. Due to the limitations of the research equipment, which differed from those used in actual industrial settings, it was challenging to assess the effects in actual industrial environment. Therefore, to show an actual industrial environment, we conducted the cleaning process on a 12-inch PECVD chamber, which is production-level equipment, and quantitatively analyzed the effects of each variable. Power, Pressure, and NF3 Flow all had P-values close to 0, indicating strong statistical significance. The weight for Flow is 15.68, and the weights for Power and Pressure are 4.45 and 5.24, respectively, showing effects 3 and 7 times greater than those with the 6-inch equipment on the cleaning rate. Additionally, we analyzed the cleaning Stdev and derived that there is a trade-off between increasing the cleaning Rate and reducing the cleaning Stdev.

  • PDF

Analysis of Maintenance Conditions for Small Photovoltaic Equipment (소형 태양광발전설비의 유지관리 실태 분석)

  • Kang, Seok-Hwa;Kim, Jae-Yeob
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.115-116
    • /
    • 2014
  • This study investigated power generation of photovoltaic equipment at detached houses. The study estimated monthly mean generation according to maintenance conditions that included module cleaning, inspection into generation, cleaning of module and photovoltaic generation. At analysis upon generation, households with periodical module cleaning and inspection into generation, clean module and good generation conditions had high generation. 20-years of PV equipment life varied much depending upon maintenance conditions. Users should keep module clean and inspect generation regularly and put PV equipment at the place with good solar radiation.

  • PDF