• Title/Summary/Keyword: Cleaning Effect

Search Result 625, Processing Time 0.031 seconds

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source (플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.44-51
    • /
    • 2008
  • UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-Barrier Discharges (DBDs), also referred to as barrier discharges or silent discharges have been exclusively related to ozone generation for a long time. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, hi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.

The Effect of Cleaning the Intake System of LPG Vehicles on Engine and Emissions (LPG차량 흡기계통 Cleaning이 엔진 및 배출가스에 미치는 영향)

  • Hong, Sung-In;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1229-1235
    • /
    • 2014
  • At the LPG vehicle air intake system, most of dust particles in the air cleaner are removed. However very small particles are not removed and accumulated. The accumulation of carbon in air intake system is going to affect the idle speed control and sensor signal. It also causes engine chattering and transmission troubles of automatic transmission. This is study about cleaning up intake system using cleaning chemical. We can clean up the intake system by spraying cleaning liquid onto intake device when the engine is idling after intake hose is removed from warmed up vehicle. We can obtain the following experimental results by cleaning up ISC, surge tank, intake manifold, intake valves and combustion chamber. According to this results, the stroll valve works correctly and power rate of engine is up to the standard, it is smoothy to control the idling speed when a vehicle pulls up. After cleaning up CO grow down about 0.15%, HC does about 20~100 ppm.

The Change of Physical Properties of Artificial aging Paper in the Cleaning Process for the Conservation Treatment of Historical Paper Documents - Focusing on Immersion Wet Cleaning - (고문헌 보존처리의 클리닝 방법에 따른 인공열화지 물성 변화 - 침적 습식클리닝을 중심으로 -)

  • Jeong, Seon Hwa;Cho, An Naa
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.1
    • /
    • pp.228-237
    • /
    • 2013
  • Paper relics are affected by a number of complex physical, chemical, biological and artificial damaging factors due to the vulnerability of organic materials. Wet cleaning is a conservation treatment method for removing pollutants from paper artefacts. This study was carried out in order to analyse the effect of wet cleaning on Hanji (Traditional Korean paper made from mulberry trees) which is the main material used in Korean paper relics (historical paper documents). For this study, the color change and folding endurance of artificially degraded paper was analysed before and after immersion wet cleaning. The result showed that washing each twice in 30 minutes is the most appropriate method for obtaining cleaning efficiency and material stability.

Cleaning Behavior of Aqueous Solution Containing Amine or Carboxylic Acid in Cu-interconnection Process (아민과 카르복실산이 함유된 수계용액의 구리 배선 공정의 세정특성)

  • Ko, Cheonkwang;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.632-638
    • /
    • 2021
  • With the copper interconnection in the semiconductor process, complex residues including copper oxide, fluoride, and polymeric fluorocarbon are formed by plasma etching. In this study, a cleaning solution was prepared with a component having an amine group (-NH2) and a carboxyl group (-COOH), and the characteristics of removing post-etch residues in the copper wiring process were analyzed. In the cleaning solution containing an amine group, the length of the component substituted with nitrogen and the length of the carbon chain influenced the cleaning effect, and the etching rate of copper oxide increased as the pH of the cleaning solution increased. The activity of the amine group is in the basic region, and the activity of the carboxyl group is in the acidic region, and the cleaning process proceeds through complex formation with copper or copper oxide in each region.

Chemically enhanced steam cleaning for the control of ceramic membrane fouling caused by manganese and humic acid (망간과 휴믹산에 의한 세라믹 막 오염의 제어를 위한 약품 스팀세정의 적용)

  • An, Sun-A;Park, Cheol-Gyu;Lee, Jin-San;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.425-436
    • /
    • 2021
  • In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, R c/R f increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.

A Study of Toothpaste Containing Pyrophosphates and Cellulose on the Abrasivity and Cleaning Power (피로인산염과 셀룰로오스 배합 세치제의 마모력과 세정력에 관한 연구)

  • Kim, Byung-Jun;Kim, Ji-Hye;Ha, Won-Ho;Ahn, Jae-Hyun
    • Journal of dental hygiene science
    • /
    • v.13 no.1
    • /
    • pp.83-90
    • /
    • 2013
  • The aim of this study was to evaluate the abrasive effect and cleaning power of toothpaste containing tetrasodium pyrophosphate and cellulose. The relative dentin abrasivity, cleaning power by modified Stookey method, dentin abrasivity of brushing after Cola treatment and consumer survey were investigated with control toothpaste containing dental type silica as an abrasive. The results obtained were as follows: 1. Experimental toothpaste hardly influenced dentin abrasivity, but control toothpaste had an effect on dentin abrasivity significantly (p<0.05). 2. There was no significant difference in cleaning power between experimental and control toothpaste (p>0.05). 3. Experimental toothpaste hardly influenced dentin abrasivity, despite 100 or 1,000 times of brushing after Cola treatment, but control toothpaste showed a big increase in dentin abrasivity as the number of brushing has been increased (p<0.05). 4. According to the consumer survey results, there was no difference between control and experimental toothpaste in the satisfaction rate of refreshing sensation, the satisfaction rate of the lasting effect of refreshing sensation and the overall satisfaction rate of the toothpaste (p>0.05). These results showed a possibility to make abrasive free toothpaste having cleaning power without dentin abrasivity.

A study of the effect of S-city's air pollution cleaning cost. (S시의 대기환경관련 투자 효과에 관한 연구)

  • Choi, Young-Tei;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.11a
    • /
    • pp.283-286
    • /
    • 2006
  • The study of The cost of cleaning S-city's air pollution is effective. The cost is calculated by ABC distribution system and analysed the air pollution and cost's correlation. Because the whole air pollution's analysis is so heavy, We did about vehicle's pollution.

  • PDF

Study on the efficiency of cleaning Process for Screen printing cleaning (스크린 인쇄 세정에 대한 세정공정 효율 연구)

  • 최성용
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.15 no.1
    • /
    • pp.85-96
    • /
    • 1997
  • The color difference between original and printed copy is affected mainly by ink trapping and optical properties of overprinted ink layer. Since the general expression itself about ink trapping is affected also by the optical properties, the analysis of color difference using the ink trapping only cannot be certain. This study will show a new approaching method for optical analysis of spectral reflectance and the effect of printing sequence on color difference in multi-color overprints under the condition of excluding completely the ink trapping problems by means of using transparent film as a substrate.

  • PDF

Impacts of Fouling and Cleaning on the Performance of Plate Fin and Spine Fin Heat Exchangers

  • Pak, Bock-Choon;Baek, Byung-Joon;Eckhard A. Groll
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1801-1811
    • /
    • 2003
  • An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.